PROCESS ID: NSELECTA DESCRIPTION: N SELECT ANNEAL AT 750 DEG 45 MIN ST BANK: 1 TUBES: 1,2,3,4,7 REUSE: YES 0001.0000 IDLE 0001.0005 STEP N2=2.5 0001.0010 STEP TEMPL=750 0001.0015 STEP TEMPC=750 0001.0020 STEP TEMPS=750 0001.0025 STEP UNLOAD=OFF 0001.0030 STEP LOAD=ON 0001.0035 STEP SPEED=10 0005.0000 BOAT OUT 0005.0005 STEP TIME:00:00:00 0005.0010 STEP N2=5.0 0005.0015 STEP TEMPL=700 0005.0020 STEP TEMPC=725 0005.0025 STEP TEMPS=725 0005.0030 STEP LOAD=OFF 0005.0035 STEP UNLOAD=ON 0005.0040 STEP SPEED=8 0005.0045 STEP TCU LEARN=OFF 0005.0050 STEP IF ALMACK=ON GOTO 0010 0010.0000 BOAT IN AND 1ST STABILIZE TO +- 5 DEG 0010.0005 STEP TIME:00:20:00 0010.0010 STEP TEMPL=750 0010.0015 STEP TEMPC=750 0010.0020 STEP TEMPS=750 0010.0025 STEP UNLOAD=OFF 0010.0030 STEP LOAD=ON 0010.0035 STEP SPEED=12 0010.0040 STEP TCU LEARN=OFF 0015.0000 ANNEAL 0015.0005 STEP TIME:00:45:00 0015.0010 STEP N2=2.5 0015.0015 STEP TCU CTLID=0 0015.0020 STEP TCU LEARN=OFF 0020.0000 BOAT OUT 0020.0005 STEP TIME:00:00:00 0020.0010 STEP TEMPL=650 0020.0015 STEP TEMPC=675 0020.0020 STEP TEMPS=675 0020.0025 STEP LOAD=OFF 0020.0030 STEP UNLOAD=ON 0020.0035 STEP SPEED=10 0020.0040 STEP TCU LEARN=OFF 0020.0045 STEP IF ALMACK=ON GOTO 0025 0025.0000 END 0025.0005 STEP END PROCESS