PROCESS ID: QTCACL DESCRIPTION: QUICK TCA CLEAN AT 850 DEG ST BANK: 1 TUBES: 1,2,3,4,7 REUSE: YES 0001.0000 IDLE 0001.0005 STEP N2=2.5 0001.0010 STEP O2HI=OFF 0001.0015 STEP O2HI=0 0001.0020 STEP TEMPL=800 0001.0025 STEP TEMPC=800 0001.0030 STEP TEMPS=800 0001.0035 STEP UNLOAD=OFF 0001.0040 STEP LOAD=ON 0001.0045 STEP SPEED=0 0001.0050 STEP TCU LEARN=OFF 0005.0000 RAMPUP 0005.0005 STEP TIME:00:00:00 0005.0010 STEP TEMPL=850 0005.0015 STEP TEMPC=850 0005.0020 STEP TEMPS=850 0005.0025 STEP N2=OFF 0005.0030 STEP N2=0 0005.0035 STEP O2HI=2500 0005.0040 STEP TEMPC TOLERANCE=1.0 0005.0045 STEP IF TEMPC>800 GOTO 0010 0005.0050 STEP TCU CTLID=2 0005.0055 STEP TCU LEARN=OFF 0010.0000 START CARR FLOW 0010.0005 STEP TIME:00:00:30 0010.0010 STEP N2CARR=30 0010.0015 STEP TCU CTLID=2 0010.0020 STEP TCU LEARN=OFF 0015.0000 START SOURCE FLOW 0015.0005 STEP TIME:00:00:10 0015.0010 STEP TCA=ON 0015.0015 STEP TCU CTLID=2 0015.0020 STEP TCU LEARN=OFF 0020.0000 DRY CLEAN 0020.0005 STEP TIME:00:20:00 0020.0010 STEP TCU CTLID=2 0020.0015 STEP TCU LEARN=OFF 0025.0000 LINE PURGE 0025.0005 STEP TIME:00:10:00 0025.0010 STEP TEMPL=875 0025.0015 STEP TEMPC=875 0025.0020 STEP TEMPS=875 0025.0025 STEP TCA=OFF 0025.0030 STEP TCU CTLID=2 0025.0035 STEP TCU LEARN=OFF 0030.0000 STEAM 0030.0005 STEP TIME:00:20:00 0030.0010 STEP TUBE=OFF 0030.0015 STEP N2CARR=OFF 0030.0020 STEP N2CARR=0 0030.0025 STEP O2HI=1000 0030.0030 STEP H2/O2=150 0030.0035 STEP TCU CTLID=22 0030.0040 STEP TCU LEARN=OFF 0035.0000 PURGE 0035.0005 STEP TIME:00:10:00 0035.0010 STEP TEMPL=750 0035.0015 STEP TEMPC=750 0035.0020 STEP TEMPS=750 0035.0025 STEP H2/O2=OFF 0035.0030 STEP H2/O2=0 0035.0035 STEP O2HI=2500 0035.0040 STEP TCU LEARN=OFF 0040.0000 PURGE 0040.0005 STEP TIME:00:05:00 0040.0010 STEP O2HI=OFF 0040.0015 STEP O2HI=0 0040.0020 STEP N2=2.5 0040.0025 STEP TCU LEARN=OFF 0045.0000 STANDBY 0045.0005 STEP TIME:00:00:00 0045.0010 STEP IF ALMACK=ON GOTO 0050 0045.0015 STEP TCU LEARN=OFF 0050.0000 END 0050.0005 STEP END PROCESS