PROCESS ID: TCACLEAN DESCRIPTION: HI TEMP CLEAN W/TCA & STEAM ST BANK: 1 TUBES: 1,2,3,4,7 REUSE: YES 0001.0000 IDLE 0001.0005 STEP N2=2.5 0001.0010 STEP O2HI=OFF 0001.0015 STEP O2HI=0 0001.0020 STEP TEMPL=800 0001.0025 STEP TEMPC=800 0001.0030 STEP TEMPS=800 0001.0035 STEP UNLOAD=OFF 0001.0040 STEP LOAD=ON 0001.0045 STEP SPEED=15 0001.0050 STEP TCU LEARN=OFF 0005.0000 RAMPUP 0005.0005 STEP TIME:00:00:00 0005.0010 STEP TEMPL=1050 0005.0015 STEP TEMPC=1050 0005.0020 STEP TEMPS=1050 0005.0025 STEP N2=OFF 0005.0030 STEP N2=0 0005.0035 STEP O2HI=2500 0005.0040 STEP TEMPC TOLERANCE=1.0 0005.0045 STEP IF TEMPC>950 GOTO 0010 0005.0050 STEP TCU CTLID=2 0005.0055 STEP TCU LEARN=OFF 0010.0000 START CARR FLOW 0010.0005 STEP TIME:00:01:00 0010.0010 STEP N2CARR=30 0010.0015 STEP TCU CTLID=7 0010.0020 STEP TCU LEARN=OFF 0015.0000 START SOURCE FLOW 0015.0005 STEP TIME:00:00:10 0015.0010 STEP TCA=ON 0015.0015 STEP TCU CTLID=7 0015.0020 STEP TCU LEARN=OFF 0020.0000 DRY CLEAN 0020.0005 STEP TIME:02:00:00 0020.0010 STEP TCU CTLID=7 0020.0015 STEP TCU LEARN=OFF 0025.0000 LINE PURGE 0025.0005 STEP TIME:00:30:00 0025.0010 STEP TEMPL=1050 0025.0015 STEP TEMPC=1050 0025.0020 STEP TEMPS=1050 0025.0025 STEP TCA=OFF 0025.0030 STEP TCU CTLID=7 0025.0035 STEP TCU LEARN=OFF 0030.0000 STEAM 0030.0005 STEP TIME:02:30:00 0030.0010 STEP TUBE=OFF 0030.0015 STEP N2CARR=OFF 0030.0020 STEP O2HI=1000 0030.0025 STEP H2/O2=150 0030.0030 STEP TCU CTLID=26 0030.0035 STEP TCU LEARN=OFF 0035.0000 PURGE 0035.0005 STEP TIME:00:30:00 0035.0010 STEP H2/O2=OFF 0035.0015 STEP H2/O2=0 0035.0020 STEP O2HI=2500 0035.0025 STEP TCU CTLID=7 0035.0030 STEP TCU LEARN=OFF 0040.0000 START CARR FLOW 0040.0005 STEP TIME:00:01:00 0040.0010 STEP N2CARR=30 0040.0015 STEP TCU CTLID=7 0040.0020 STEP TCU LEARN=OFF 0045.0000 START SOURCE FLOW 0045.0005 STEP TIME:00:00:10 0045.0010 STEP TCA=ON 0045.0015 STEP TCU CTLID=7 0045.0020 STEP TCU LEARN=OFF 0050.0000 DRY CLEAN 0050.0005 STEP TIME:02:30:00 0050.0010 STEP TCU CTLID=7 0050.0015 STEP TCU LEARN=OFF 0055.0000 LINE PURGE 0055.0005 STEP TIME:00:30:00 0055.0010 STEP TEMPL=1050 0055.0015 STEP TEMPC=1050 0055.0020 STEP TEMPS=1050 0055.0025 STEP TCA=OFF 0055.0030 STEP TCU CTLID=7 0055.0035 STEP TCU LEARN=OFF 0060.0000 STEAM 0060.0005 STEP TIME:02:30:00 0060.0010 STEP TUBE=OFF 0060.0015 STEP N2CARR=OFF 0060.0020 STEP N2CARR=0 0060.0025 STEP O2HI=1000 0060.0030 STEP H2/O2=150 0060.0035 STEP TCU CTLID=26 0060.0040 STEP TCU LEARN=OFF 0065.0000 PURGE 0065.0005 STEP TIME:00:30:00 0065.0010 STEP O2HI=2500 0065.0015 STEP N2CARR=OFF 0065.0020 STEP N2CARR=0 0065.0025 STEP H2/O2=OFF 0065.0030 STEP H2/O2=0 0065.0035 STEP TCU CTLID=7 0065.0040 STEP TCU LEARN=OFF 0070.0000 RAMPDOWN 0070.0005 STEP TIME:00:00:00 0070.0010 STEP O2HI=OFF 0070.0015 STEP O2HI=0 0070.0020 STEP N2=5.0 0070.0025 STEP TEMPL=750 0070.0030 STEP TEMPC=750 0070.0035 STEP TEMPS=750 0070.0040 STEP IF ALMACK=ON GOTO 0075 0075.0000 END 0075.0005 STEP END PROCESS