PROCESS ID: 300AN11 DESCRIPTION: N2 ANNEAL AT 300 DEG SKB BANK: 3 TUBES: 11 REUSE: YES 0001.0000 IDLE 0001.0005 STEP VACUUM=OFF 0001.0010 STEP N2PURG=1000 0001.0015 STEP TEMPL=300 0001.0020 STEP TEMPC=300 0001.0025 STEP TEMPS=300 0001.0030 STEP UNLOAD=OFF 0001.0035 STEP LOAD=ON 0001.0040 STEP SPEED=25 0005.0000 BOAT OUT 0005.0005 STEP TIME:00:00:00 0005.0010 STEP N2PURG=3000 0005.0015 STEP LOAD=OFF 0005.0020 STEP UNLOAD=ON 0005.0025 STEP SPEED=12 0005.0030 STEP IF ALMACK=ON GOTO 0010 0010.0000 BOAT IN 0010.0005 STEP TIME:00:00:00 0010.0010 STEP TEMPL=300 0010.0015 STEP TEMPC=300 0010.0020 STEP TEMPS=300 0010.0025 STEP UNLOAD=OFF 0010.0030 STEP LOAD=ON 0010.0035 STEP SPEED=10 0010.0040 STEP TCU CTLID=1 0010.0045 STEP TCU LEARN=OFF 0010.0050 STEP IF DNTLK=ON GOTO 0015 0015.0000 PRE PUMP STABILIZE TO +-5 DEG 0015.0005 STEP TIME:00:02:00 0015.0010 STEP N2PURG=3000 0015.0015 STEP TCU CTLID=1 0015.0020 STEP TCU LEARN=OFF 0020.0000 STABILIZE 0020.0005 STEP TIME:00:10:00 0020.0010 STEP N2PURG=100 0020.0015 STEP VACUUM=ON 0020.0020 STEP TCU LEARN=OFF 0025.0000 INITIAL PUMPDOWN 0025.0005 STEP TIME:00:04:00 0025.0010 STEP N2PURG=0 0025.0015 STEP N2PURG=OFF 0025.0020 STEP VACUUM=ON 0025.0025 STEP TCU CTLID=1 0025.0030 STEP TCU LEARN=OFF 0030.0000 PUMPDOWN AND GROSS LEAK CHECK 0030.0005 STEP TIME:00:03:00 0030.0010 STEP PRCPR TOLERANCE=1.0 0030.0015 STEP IF PRCPR>500 GOTO 0060 0030.0020 STEP TCU CTLID=1 0030.0025 STEP TCU LEARN=OFF 0035.0000 LEAK CHECK 0035.0005 STEP TIME:00:01:00 0035.0010 STEP VACUUM=OFF 0035.0015 STEP IF PRCPR>100 GOTO 0055 0035.0020 STEP TCU CTLID=1 0035.0025 STEP TCU LEARN=OFF 0040.0000 REPUMP 0040.0005 STEP TIME:00:02:00 0040.0010 STEP VACUUM=ON 0040.0015 STEP TCU CTLID=1 0040.0020 STEP TCU LEARN=OFF 0045.0000 FINAL STABILIZE TO +-1 DEG 0045.0005 STEP TIME:00:05:00 0045.0010 STEP N2PURG=200 0045.0015 STEP TCU CTLID=1 0045.0020 STEP TCU LEARN=OFF 0045.0025 STEP TEMPC TOLERANCE=1.0 0045.0030 STEP IF TEMPC<255 GOTO 0055 0050.0000 ANNEAL 0050.0005 STEP TIME:VARIABLE 0050.0010 STEP N2PURG=200 0050.0015 STEP TCU CTLID=1 0050.0020 STEP TCU LEARN=OFF 0050.0025 STEP TEMPC TOLERANCE=1.0 0050.0030 STEP IF PRCPR>1000 GOTO 0055 0055.0000 SLOW BACKFILL AND ABORT 0055.0005 STEP TIME:00:20:00 0055.0010 STEP VACUUM=OFF 0055.0015 STEP N2PURG=1200 0060.0000 BOAT OUT 0060.0005 STEP TIME:00:00:00 0060.0010 STEP N2PURG=3000 0060.0015 STEP LOAD=OFF 0060.0020 STEP UNLOAD=ON 0060.0025 STEP SPEED=10 0060.0030 STEP IF ALMACK=ON GOTO 0065 0065.0000 END 0065.0005 STEP END PROCESS