PROCESS ID: PURGE10 DESCRIPTION: SEALING OF TUBE ST BANK: 3 TUBES: 10 REUSE: YES 0001.0000 IDLE 0001.0005 STEP N2PURG=3000 0001.0010 STEP TEMPL=585 0001.0015 STEP TEMPC=590 0001.0020 STEP TEMPS=590 0001.0025 STEP UNLOAD=OFF 0001.0030 STEP LOAD=ON 0001.0035 STEP SPEED=25 0005.0000 PRE PUMP STABILIZE TO +-5 DEG 0005.0005 STEP TIME:00:00:15 0005.0010 STEP N2PURG=1500 0005.0015 STEP TCU LEARN=OFF 0010.0000 INITIAL PUMPDOWN 0010.0005 STEP TIME:00:03:00 0010.0010 STEP N2PURG=110 0010.0015 STEP VACUUM=ON 0010.0020 STEP TEMPL=779 0010.0025 STEP TEMPC=785 0010.0030 STEP TEMPS=791 0010.0035 STEP TCU CTLID=2 0010.0040 STEP TCU LEARN=OFF 0015.0000 STABILIZE 0015.0005 STEP TIME:00:10:00 0015.0010 STEP N2PURG=100 0015.0015 STEP TCU CTLID=2 0015.0020 STEP TCU LEARN=OFF 0020.0000 FINAL STABILIZATION 0020.0005 STEP TIME:00:05:00 0020.0010 STEP N2PURG=110 0020.0015 STEP TCU CTLID=2 0020.0020 STEP TCU LEARN=OFF 0020.0025 STEP IF PRCPR>1200 GOTO 0040 0020.0030 STEP IF TEMPC<650 GOTO 0040 0025.0000 START AMMONIA FLOW 0025.0005 STEP TIME:00:00:30 0025.0010 STEP N2PURG=OFF 0025.0015 STEP N2PURG=0 0025.0020 STEP NH3=120 0025.0025 STEP TCU CTLID=2 0025.0030 STEP TCU LEARN=OFF 0030.0000 *DEPOSITION* 0030.0005 STEP TIME:00:15:00 0030.0010 STEP DCS=40 0030.0015 STEP TCU CTLID=2 0030.0020 STEP TCU LEARN=OFF 0030.0025 STEP IF PRCPR>1200 GOTO 0040 0035.0000 AMMONIA PURGE 0035.0005 STEP TIME:00:03:00 0035.0010 STEP DCS=OFF 0035.0015 STEP DCS=0 0035.0020 STEP TEMPL=560 0035.0025 STEP TEMPC=560 0035.0030 STEP TEMPS=560 0035.0035 STEP TCU LEARN=OFF 0035.0040 STEP IF PRCPR>1200 GOTO 0040 0040.0000 1ST PUMPDOWN 0040.0005 STEP TIME:00:03:00 0040.0010 STEP NH3=OFF 0040.0015 STEP NH3=0 0040.0020 STEP N2PURG=0 0040.0025 STEP N2PURG=OFF 0040.0030 STEP N2PURG=OFF 0040.0035 STEP TCU LEARN=OFF 0045.0000 1ST PURGE 0045.0005 STEP TIME:00:01:00 0045.0010 STEP N2PURG=300 0050.0000 2ND PUMP DOWN 0050.0005 STEP TIME:00:01:00 0050.0010 STEP N2PURG=300 0055.0000 2ND PURGE 0055.0005 STEP TIME:00:01:00 0055.0010 STEP N2PURG=100 0060.0000 FINAL PUMP DOWN 0060.0005 STEP TIME:00:01:00 0060.0010 STEP N2PURG=300 0065.0000 FINAL PURGE AND RAMPDOWN 0065.0005 STEP TIME:00:00:00 0065.0010 STEP N2PURG=715 0065.0015 STEP N2BKFL=50 0065.0020 STEP TEMPL TOLERANCE=1.0 0065.0025 STEP IF ALMACK=ON GOTO 0070 0065.0030 STEP TCU LEARN=OFF 0070.0000 SLOW BACKFILL AND ABORT STEP 0070.0005 STEP TIME:00:08:00 0070.0010 STEP VACUUM=OFF 0070.0015 STEP TEMPL=500 0070.0020 STEP TEMPC=500 0070.0025 STEP TEMPS=500 0070.0030 STEP N2PURG=2800 0070.0035 STEP N2BKFL=750 0070.0040 STEP TCU LEARN=OFF 0075.0000 BOAT OUT 0075.0005 STEP TIME:00:00:00 0075.0010 STEP N2BKFL=OFF 0075.0015 STEP N2BKFL=0 0075.0020 STEP N2PURG=2500 0075.0025 STEP TEMPL=500 0075.0030 STEP TEMPC=525 0075.0035 STEP TEMPS=550 0075.0040 STEP LOAD=OFF 0075.0045 STEP UNLOAD=ON 0075.0050 STEP SPEED=25 0075.0055 STEP IF ALMACK=ON GOTO 0080 0080.0000 END 0080.0005 STEP END PROCESS