PROCESS ID: SIN3.0M DESCRIPTION: SIN3.0 WITH MORE ZONE TEMP RAMP BANK: 3 TUBES: 10 REUSE: YES 0001.0000 IDLE 0001.0005 STEP N2PURG=2500 0001.0010 STEP TEMPL=590 0001.0015 STEP TEMPC=595 0001.0020 STEP TEMPS=595 0001.0025 STEP UNLOAD=OFF 0001.0030 STEP LOAD=ON 0001.0035 STEP SPEED=25 0005.0000 BOAT OUT 0005.0005 STEP TIME:00:00:00 0005.0010 STEP N2PURG=2000 0005.0015 STEP N2BKFL=100 0005.0020 STEP TEMPL=585 0005.0025 STEP TEMPC=600 0005.0030 STEP TEMPS=595 0005.0035 STEP LOAD=OFF 0005.0040 STEP UNLOAD=ON 0005.0045 STEP SPEED=25 0005.0050 STEP IF ALMACK=ON GOTO 0010 0010.0000 BOAT IN 0010.0005 STEP TIME:00:00:00 0010.0010 STEP TEMPL=700 0010.0015 STEP TEMPC=700 0010.0020 STEP TEMPS=700 0010.0025 STEP UNLOAD=OFF 0010.0030 STEP LOAD=ON 0010.0035 STEP SPEED=25 0010.0040 STEP TCU CTLID=1 0010.0045 STEP IF DNTLK=ON GOTO 0015 0010.0050 STEP TCU LEARN=OFF 0010.0055 STEP N2PURG=650 0010.0060 STEP N2BKFL=45 0015.0000 PRE PUMP STABILIZE TO +-5 DEG 0015.0005 STEP TIME:00:00:10 0015.0010 STEP N2PURG=1500 0015.0015 STEP N2BKFL=OFF 0015.0020 STEP N2BKFL=0 0015.0025 STEP TCU LEARN=OFF 0020.0000 INITIAL PUMPDOWN 0020.0005 STEP TIME:00:04:00 0020.0010 STEP N2PURG=100 0020.0015 STEP VACUUM=ON 0020.0020 STEP TEMPL=770 0020.0025 STEP TEMPC=785 0020.0030 STEP TEMPS=810 0020.0035 STEP TCU CTLID=2 0020.0040 STEP TCU LEARN=OFF 0025.0000 STABILIZE 0025.0005 STEP TIME:00:20:00 0025.0010 STEP N2PURG=100 0025.0015 STEP TCU CTLID=2 0025.0020 STEP TCU LEARN=OFF 0030.0000 PUMP DOWN 0030.0005 STEP TIME:00:03:00 0030.0010 STEP N2PURG=OFF 0030.0015 STEP N2PURG=0 0030.0020 STEP TCU CTLID=2 0030.0025 STEP TCU LEARN=OFF 0030.0030 STEP IF TEMPC<700 GOTO 0080 0035.0000 PUMPDOWN AND GROSS LEAK CHECK 0035.0005 STEP TIME:00:03:00 0035.0010 STEP TCU CTLID=2 0035.0015 STEP PRCPR TOLERANCE=1.0 0035.0020 STEP IF PRCPR>500 GOTO 0110 0035.0025 STEP TCU LEARN=OFF 0040.0000 LEAK CHECK 0040.0005 STEP TIME:00:01:00 0040.0010 STEP TCU CTLID=2 0040.0015 STEP VACUUM=OFF 0040.0020 STEP IF PRCPR>60 GOTO 0110 0040.0025 STEP TCU LEARN=OFF 0045.0000 REPUMP 0045.0005 STEP TIME:00:02:00 0045.0010 STEP VACUUM=ON 0045.0015 STEP TCU CTLID=2 0045.0020 STEP TCU LEARN=OFF 0050.0000 START PURGE 0050.0005 STEP TIME:00:02:00 0050.0010 STEP N2PURG=100 0050.0015 STEP TCU CTLID=2 0050.0020 STEP TCU LEARN=OFF 0055.0000 FINAL STABILIZE TO +-1 DEG 0055.0005 STEP TIME:00:25:00 0055.0010 STEP N2PURG=125 0055.0015 STEP TCU CTLID=2 0055.0020 STEP TCU LEARN=OFF 0055.0025 STEP IF PRCPR>1200 GOTO 0080 0060.0000 PUMP DOWN 0060.0005 STEP TIME:00:00:15 0060.0010 STEP TCU CTLID=2 0060.0015 STEP TCU LEARN=OFF 0065.0000 START AMMONIA FLOW 0065.0005 STEP TIME:00:01:00 0065.0010 STEP N2PURG=OFF 0065.0015 STEP N2PURG=0 0065.0020 STEP NH3=50 0065.0025 STEP TCU CTLID=2 0065.0030 STEP TCU LEARN=OFF 0065.0035 STEP IF PRCPR>1200 GOTO 0080 0070.0000 *DEPOSITION* 0070.0005 STEP TIME:VARIABLE 0070.0010 STEP DCS=150 0070.0015 STEP TCU CTLID=2 0070.0020 STEP TCU LEARN=OFF 0070.0025 STEP IF PRCPR>1200 GOTO 0080 0075.0000 AMMONIA PURGE 0075.0005 STEP TIME:00:01:00 0075.0010 STEP DCS=OFF 0075.0015 STEP DCS=0 0075.0020 STEP TCU LEARN=OFF 0075.0025 STEP IF PRCPR>1200 GOTO 0080 0080.0000 1ST PUMPDOWN 0080.0005 STEP TIME:00:02:00 0080.0010 STEP NH3=OFF 0080.0015 STEP NH3=0 0080.0020 STEP DCS=OFF 0080.0025 STEP DCS=0 0080.0030 STEP TCU LEARN=OFF 0085.0000 1ST PURGE 0085.0005 STEP TIME:00:01:00 0085.0010 STEP N2PURG=300 0085.0015 STEP TEMPL=560 0085.0020 STEP TEMPC=560 0085.0025 STEP TEMPS=560 0085.0030 STEP TCU LEARN=OFF 0090.0000 2ND PUMP DOWN 0090.0005 STEP TIME:00:01:00 0090.0010 STEP N2PURG=100 0095.0000 2ND PURGE 0095.0005 STEP TIME:00:01:00 0095.0010 STEP N2PURG=300 0100.0000 FINAL PUMP DOWN 0100.0005 STEP TIME:00:01:00 0100.0010 STEP N2PURG=100 0105.0000 FINAL PURGE AND RAMPDOWN 0105.0005 STEP TIME:00:00:00 0105.0010 STEP N2PURG=650 0105.0015 STEP N2BKFL=45 0105.0020 STEP TEMPL TOLERANCE=1.0 0105.0025 STEP IF TEMPL<600 GOTO 0110 0105.0030 STEP TCU LEARN=OFF 0110.0000 SLOW BACKFILL AND ABORT STEP 0110.0005 STEP TIME:00:08:00 0110.0010 STEP VACUUM=OFF 0110.0015 STEP TEMPL=550 0110.0020 STEP TEMPC=550 0110.0025 STEP TEMPS=550 0110.0030 STEP N2PURG=2500 0110.0035 STEP N2BKFL=750 0110.0040 STEP TCU LEARN=OFF 0115.0000 BOAT OUT 0115.0005 STEP TIME:00:00:00 0115.0010 STEP N2BKFL=OFF 0115.0015 STEP N2BKFL=0 0115.0020 STEP N2PURG=2500 0115.0025 STEP TEMPL=500 0115.0030 STEP TEMPC=525 0115.0035 STEP TEMPS=550 0115.0040 STEP LOAD=OFF 0115.0045 STEP UNLOAD=ON 0115.0050 STEP SPEED=25 0115.0055 STEP IF ALMACK=ON GOTO 0120 0120.0000 END 0120.0005 STEP END PROCESS