PROCESS ID: PREPURGE DESCRIPTION: POLY PRE PURGE ST BANK: 3 TUBES: 9 REUSE: YES 0001.0000 IDLE 0001.0005 STEP VACUUM=OFF 0001.0010 STEP N2PURG=2000 0001.0015 STEP TEMPL=560 0001.0020 STEP TEMPC=560 0001.0025 STEP TEMPS=560 0001.0030 STEP UNLOAD=OFF 0001.0035 STEP LOAD=ON 0001.0040 STEP SPEED=25 0001.0045 STEP TCU LEARN=OFF 0005.0000 INITIAL PUMPDOWN 0005.0005 STEP TIME:00:03:00 0005.0010 STEP N2PURG=300 0005.0015 STEP VACUUM=ON 0005.0020 STEP TEMPL=617.0 0005.0025 STEP TEMPC=620.0 0005.0030 STEP TEMPS=623.0 0005.0035 STEP TCU CTLID=2 0005.0040 STEP TCU LEARN=OFF 0010.0000 START PURGE 0010.0005 STEP TIME:00:01:00 0010.0010 STEP N2PURG=150 0010.0015 STEP TCU CTLID=2 0010.0020 STEP TCU LEARN=OFF 0015.0000 STABILZE 0015.0005 STEP TIME:00:02:00 0015.0010 STEP TCU CTLID=2 0015.0015 STEP TCU LEARN=OFF 0015.0020 STEP IF PRCPR>1200 GOTO 0060 0020.0000 PUMP DOWN 0020.0005 STEP TIME:00:02:00 0020.0010 STEP N2PURG=OFF 0020.0015 STEP N2PURG=0 0020.0020 STEP TCU CTLID=2 0020.0025 STEP TCU LEARN=OFF 0025.0000 PUMPDOWN AND GROSS LEAK CHECK 0025.0005 STEP TIME:00:01:00 0025.0010 STEP TCU CTLID=2 0025.0015 STEP PRCPR TOLERANCE=1.0 0025.0020 STEP IF PRCPR>500 GOTO 0105 0030.0000 LEAK CHECK 0030.0005 STEP TIME:00:01:00 0030.0010 STEP TCU CTLID=2 0030.0015 STEP VACUUM=OFF 0030.0020 STEP TCU LEARN=OFF 0030.0025 STEP IF PRCPR>60 GOTO 0105 0035.0000 REPUMP 0035.0005 STEP TIME:00:02:00 0035.0010 STEP VACUUM=ON 0035.0015 STEP IF TEMPC<560 GOTO 0060 0035.0020 STEP TCU CTLID=2 0035.0025 STEP TCU LEARN=OFF 0040.0000 START FLOW 0040.0005 STEP TIME:00:01:00 0040.0010 STEP N2PURG=135 0040.0015 STEP TCU CTLID=2 0040.0020 STEP TCU LEARN=OFF 0045.0000 FINAL STABILIZE TO +-1 DEG 0045.0005 STEP TIME:00:02:00 0045.0010 STEP H2=110 0045.0015 STEP TCU CTLID=2 0045.0020 STEP TCU LEARN=OFF 0045.0025 STEP IF PRCPR>1200 GOTO 0060 0050.0000 *DEPOSITION* 0050.0005 STEP TIME:00:20:00 0050.0010 STEP N2PURG=OFF 0050.0015 STEP N2PURG=0 0050.0020 STEP SIH4=136 0050.0025 STEP H2=110 0050.0030 STEP TCU CTLID=2 0050.0035 STEP TCU LEARN=OFF 0050.0040 STEP IF PRCPR>1200 GOTO 0060 0055.0000 H2 PURGE 0055.0005 STEP TIME:00:00:30 0055.0010 STEP SIH4=0 0055.0015 STEP SIH4=OFF 0055.0020 STEP TCU CTLID=3 0055.0025 STEP TCU LEARN=OFF 0055.0030 STEP IF PRCPR>1200 GOTO 0060 0060.0000 1ST PUMP DOWN 0060.0005 STEP TIME:00:03:00 0060.0010 STEP SIH4=OFF 0060.0015 STEP SIH4=0 0060.0020 STEP H2=OFF 0060.0025 STEP H2=0 0060.0030 STEP PRCPR=OFF 0060.0035 STEP PRCPR=0 0060.0040 STEP TEMPL=500 0060.0045 STEP TEMPC=500 0060.0050 STEP TEMPS=500 0060.0055 STEP TCU LEARN=OFF 0065.0000 1ST PURGE 0065.0005 STEP TIME:00:01:00 0065.0010 STEP N2PURG=250 0065.0015 STEP TCU LEARN=OFF 0070.0000 2ND PUMPDOWN 0070.0005 STEP TIME:00:01:00 0070.0010 STEP N2PURG=OFF 0070.0015 STEP N2PURG=0 0070.0020 STEP TCU LEARN=OFF 0075.0000 2ND PURGE 0075.0005 STEP TIME:00:01:00 0075.0010 STEP N2PURG=300 0075.0015 STEP TCU LEARN=OFF 0080.0000 PUMP DOWN 0080.0005 STEP TIME:00:01:00 0080.0010 STEP N2PURG=OFF 0080.0015 STEP N2PURG=0 0080.0020 STEP TCU LEARN=OFF 0085.0000 3RD PURGE 0085.0005 STEP TIME:00:01:00 0085.0010 STEP N2PURG=350 0085.0015 STEP TCU LEARN=OFF 0090.0000 FINAL PUMP DOWN 0090.0005 STEP TIME:00:01:00 0090.0010 STEP N2PURG=OFF 0090.0015 STEP N2PURG=0 0090.0020 STEP TCU LEARN=OFF 0095.0000 PUMP AND HOLD 0095.0005 STEP TIME:00:00:00 0095.0010 STEP N2PURG=450 0095.0015 STEP IF ALMACK=ON GOTO 0100 0095.0020 STEP TCU LEARN=OFF 0100.0000 END 0100.0005 STEP END PROCESS