PROCESS ID: BT2SHORT DESCRIPTION: BORON TUB DIFF W/O DRIVE IN ST BANK: 2 TUBES: 5 REUSE: YES 0001.0000 IDLE 0001.0005 STEP TEMPL=815 0001.0010 STEP TEMPC=815 0001.0015 STEP TEMPS=815 0001.0020 STEP UNLOAD=OFF 0001.0025 STEP LOAD=ON 0001.0030 STEP SPEED=10 0001.0035 STEP N2=2.5 0001.0040 STEP N2CARR=150 0005.0000 DOOR OPEN 0005.0005 STEP TIME:00:00:00 0005.0010 STEP N2=4.0 0005.0015 STEP TCU LEARN=OFF 0005.0020 STEP LOAD=OFF 0005.0025 STEP UNLOAD=ON 0005.0030 STEP SPEED=25 0005.0035 STEP IF ALMACK=ON GOTO 0010 0010.0000 BOAT IN 0010.0005 STEP TIME:00:00:00 0010.0010 STEP TEMPL=850 0010.0015 STEP TEMPC=850 0010.0020 STEP TEMPS=850 0010.0025 STEP UNLOAD=OFF 0010.0030 STEP LOAD=ON 0010.0035 STEP SPEED=15 0010.0040 STEP IF DNTLK=ON GOTO 0015 0010.0045 STEP TCU LEARN=OFF 0015.0000 STABILIZE 0015.0005 STEP TIME:00:15:00 0015.0010 STEP TEMPL=900 0015.0015 STEP TEMPC=900 0015.0020 STEP TEMPS=900 0015.0025 STEP O2LO=50 0015.0030 STEP TCU CTLID=1 0015.0035 STEP TCU LEARN=OFF 0020.0000 RAMP UP AND FINAL STABILIZE TO +-1.0 DEG 0020.0005 STEP TIME:00:35:00 0020.0010 STEP TEMPL=1100 0020.0015 STEP TEMPC=1100 0020.0020 STEP TEMPS=1100 0020.0025 STEP N2=6.0 0020.0030 STEP TCU CTLID=9 0020.0035 STEP TCU LEARN=OFF 0025.0000 BEGIN CARRIER FLOW 0025.0005 STEP TIME:00:01:30 0025.0010 STEP N2CARR=190 0025.0015 STEP N2=7.1 0025.0020 STEP O2LO=52 0025.0025 STEP TCU CTLID=9 0025.0030 STEP TCU LEARN=OFF 0030.0000 BEGIN SOURCE FLOW 0030.0005 STEP TIME:00:01:00 0030.0010 STEP BBR3=ON 0030.0015 STEP TCU CTLID=9 0030.0020 STEP TCU LEARN=OFF 0035.0000 DOPE 0035.0005 STEP TIME:01:10:00 0035.0010 STEP TUBE=ON 0035.0015 STEP TCU CTLID=9 0035.0020 STEP TCU LEARN=OFF 0040.0000 ANNEAL 0040.0005 STEP TIME:00:05:00 0040.0010 STEP N2=5.0 0040.0015 STEP O2LO=OFF 0040.0020 STEP O2LO=0 0040.0025 STEP BBR3=OFF 0040.0030 STEP TUBE=OFF 0040.0035 STEP TCU CTLID=4 0040.0040 STEP TCU LEARN=OFF 0045.0000 RAMP DOWN 0045.0005 STEP TIME:00:10:00 0045.0010 STEP TEMPL=900 0045.0015 STEP TEMPC=900 0045.0020 STEP TEMPS=900 0045.0025 STEP TCU LEARN=OFF 0050.0000 OXIDATION 0050.0005 STEP TIME:00:40:00 0050.0010 STEP TEMPL=775 0050.0015 STEP TEMPC=775 0050.0020 STEP TEMPS=775 0050.0025 STEP N2=OFF 0050.0030 STEP N2=0 0050.0035 STEP O2HI=3000 0050.0040 STEP TCU LEARN=OFF 0055.0000 RAMPDOWN 0055.0005 STEP TIME:00:01:00 0055.0010 STEP TUBE=OFF 0055.0015 STEP N2=3.0 0055.0020 STEP O2HI=OFF 0055.0025 STEP O2HI=0 0055.0030 STEP TEMPL=750 0055.0035 STEP TEMPC=750 0055.0040 STEP TEMPS=750 0055.0045 STEP TCU LEARN=OFF 0060.0000 BOAT OUT 0060.0005 STEP TIME:00:00:00 0060.0010 STEP TEMPL=700 0060.0015 STEP TEMPC=750 0060.0020 STEP TEMPS=775 0060.0025 STEP TCU LEARN=OFF 0060.0030 STEP LOAD=OFF 0060.0035 STEP UNLOAD=ON 0060.0040 STEP SPEED=15 0060.0045 STEP IF ALMACK=ON GOTO 0065 0065.0000 END 0065.0005 STEP END PROCESS