PROCESS ID: ISO DESCRIPTION: ISO PREDEP BANK: 1 TUBES: 5 REUSE: YES 0001.0000 IDLE 0001.0005 STEP N2=2.5 0001.0010 STEP TEMPL=800 0001.0015 STEP TEMPC=800 0001.0020 STEP TEMPS=800 0001.0025 STEP UNLOAD=OFF 0001.0030 STEP LOAD=ON 0001.0035 STEP SPEED=6 0005.0000 BOAT OUT 0005.0005 STEP TIME:00:00:00 0005.0010 STEP N2=5.0 0005.0015 STEP TEMPL=700 0005.0020 STEP TEMPC=750 0005.0025 STEP TEMPS=775 0005.0030 STEP LOAD=OFF 0005.0035 STEP UNLOAD=ON 0005.0040 STEP SPEED=8 0005.0045 STEP TCU LEARN=OFF 0005.0050 STEP IF ALMACK=ON GOTO 0010 0010.0000 BOAT IN AND 1ST STABILIZE TO +- 5 DEG 0010.0005 STEP TIME:00:20:00 0010.0010 STEP TEMPL=800 0010.0015 STEP TEMPC=800 0010.0020 STEP TEMPS=800 0010.0025 STEP UNLOAD=OFF 0010.0030 STEP LOAD=ON 0010.0035 STEP SPEED=8 0010.0040 STEP TCU CTLID=1 0010.0045 STEP TCU LEARN=OFF 0015.0000 RAMP UP AND FINAL STABILIZE TO +- 1 DEG 0015.0005 STEP TIME:01:10:00 0015.0010 STEP N2=2.4 0015.0015 STEP O2LO=100 0015.0020 STEP TEMPL=1100 0015.0025 STEP TEMPC=1100 0015.0030 STEP TEMPS=1100 0015.0035 STEP TCU CTLID=7 0015.0040 STEP TCU LEARN=OFF 0020.0000 START O2 FLOW 0020.0005 STEP TIME:00:00:30 0020.0010 STEP O2HI=VARIABLE 0020.0015 STEP TCU CTLID=7 0020.0020 STEP TCU LEARN=OFF 0025.0000 START CARR FLOW 0025.0005 STEP TIME:00:00:30 0025.0010 STEP N2CARR=VARIABLE 0025.0015 STEP O2LO=VARIABLE 0025.0020 STEP N2=VARIABLE 0025.0025 STEP TCU CTLID=7 0025.0030 STEP TCU LEARN=OFF 0030.0000 START SOURCE FLOW 0030.0005 STEP TIME:00:00:15 0030.0010 STEP BBR3=ON 0030.0015 STEP TCU CTLID=7 0030.0020 STEP TCU LEARN=OFF 0035.0000 PREDEP 0035.0005 STEP TIME:01:30:00 0035.0010 STEP TUBE=ON 0035.0015 STEP TCU CTLID=7 0035.0020 STEP TCU LEARN=OFF 0040.0000 LINE PURGE 0040.0005 STEP TIME:00:05:00 0040.0010 STEP BBR3=OFF 0040.0015 STEP TCU CTLID=7 0040.0020 STEP TCU LEARN=OFF 0045.0000 RAMP DOWN 0045.0005 STEP TIME:01:00:00 0045.0010 STEP TEMPL=700 0045.0015 STEP TEMPC=700 0045.0020 STEP TEMPS=700 0045.0025 STEP N2=5.0 0045.0030 STEP N2CARR=OFF 0045.0035 STEP O2HI=OFF 0045.0040 STEP O2HI=0 0045.0045 STEP TUBE=OFF 0045.0050 STEP O2LO=OFF 0045.0055 STEP O2LO=0 0050.0000 BOAT OUT 0050.0005 STEP TIME:00:00:00 0050.0010 STEP TEMPL=700 0050.0015 STEP TEMPC=750 0050.0020 STEP TEMPS=775 0050.0025 STEP LOAD=OFF 0050.0030 STEP UNLOAD=ON 0050.0035 STEP SPEED=6 0050.0040 STEP TCU LEARN=OFF 0050.0045 STEP IF ALMACK=ON GOTO 0055 0055.0000 END 0055.0005 STEP END PROCESS