PROCESS ID: TCACLEAN DESCRIPTION: DOPING OF TUBE WITH NEW QUARTZ ST BANK: 2 TUBES: 5 REUSE: YES 0001.0000 IDLE 0001.0005 STEP TEMPL=800 0001.0010 STEP TEMPC=800 0001.0015 STEP TEMPS=800 0001.0020 STEP UNLOAD=OFF 0001.0025 STEP LOAD=ON 0001.0030 STEP SPEED=10 0001.0035 STEP N2=2.5 0001.0040 STEP N2CARR=150 0005.0000 RAMP UP AND FINAL STABILIZE TO +-1.0 DEG 0005.0005 STEP TIME:00:00:00 0005.0010 STEP TEMPL=1150 0005.0015 STEP TEMPC=1150 0005.0020 STEP TEMPS=1150 0005.0025 STEP N2=8.2 0005.0030 STEP O2LO=50 0005.0035 STEP IF TEMPC>1100 GOTO 0010 0005.0040 STEP TEMPC TOLERANCE=1.0 0005.0045 STEP TCU CTLID=5 0005.0050 STEP TCU LEARN=OFF 0010.0000 BEGIN CARRIER FLOW 0010.0005 STEP TIME:00:00:30 0010.0010 STEP N2CARR=175 0010.0015 STEP N2=7.5 0010.0020 STEP O2LO=51 0010.0025 STEP TCU CTLID=5 0010.0030 STEP TCU LEARN=OFF 0015.0000 BEGIN SOURCE FLOW 0015.0005 STEP TIME:00:00:30 0015.0010 STEP BBR3=ON 0015.0015 STEP TCU CTLID=5 0015.0020 STEP TCU LEARN=OFF 0020.0000 DOPE 0020.0005 STEP TIME:04:30:00 0020.0010 STEP TUBE=ON 0020.0015 STEP TCU CTLID=5 0020.0020 STEP TCU LEARN=OFF 0025.0000 PURGE 0025.0005 STEP TIME:00:30:00 0025.0010 STEP BBR3=OFF 0025.0015 STEP TCU CTLID=4 0025.0020 STEP TCU LEARN=OFF 0030.0000 RAMPDOWN 0030.0005 STEP TIME:00:00:00 0030.0010 STEP TUBE=OFF 0030.0015 STEP N2=3.0 0030.0020 STEP O2LO=OFF 0030.0025 STEP O2LO=0 0030.0030 STEP TEMPL=750 0030.0035 STEP TEMPC=750 0030.0040 STEP TEMPS=750 0030.0045 STEP TCU LEARN=OFF 0035.0000 BOAT OUT 0035.0005 STEP TIME:00:00:00 0035.0010 STEP TEMPL=700 0035.0015 STEP TEMPC=750 0035.0020 STEP TEMPS=775 0035.0025 STEP TCU LEARN=OFF 0035.0030 STEP LOAD=OFF 0035.0035 STEP UNLOAD=ON 0035.0040 STEP SPEED=15 0035.0045 STEP IF ALMACK=ON GOTO 0040 0040.0000 END 0040.0005 STEP END PROCESS