PROCESS ID: WET8001 DESCRIPTION: WET800 WITH NO DRYOX STEPS FOR BHAT GS 9/12/96 BANK: 1 TUBES: 1,3,4,7 REUSE: YES 0001.0000 IDLE 0001.0005 STEP N2=2.5 0001.0010 STEP O2HI=OFF 0001.0015 STEP O2HI=0 0001.0020 STEP TEMPL=800 0001.0025 STEP TEMPC=800 0001.0030 STEP TEMPS=800 0001.0035 STEP UNLOAD=OFF 0001.0040 STEP LOAD=ON 0001.0045 STEP SPEED=10 0005.0000 BOAT PULL 0005.0005 STEP TIME:00:00:00 0005.0010 STEP N2=5.0 0005.0015 STEP TEMPL=700 0005.0020 STEP TEMPC=750 0005.0025 STEP TEMPS=800 0005.0030 STEP LOAD=OFF 0005.0035 STEP UNLOAD=ON 0005.0040 STEP SPEED=10 0005.0045 STEP TCU LEARN=OFF 0005.0050 STEP IF ALMACK=ON GOTO 0010 0010.0000 BOAT IN AND STABILIZE 0010.0005 STEP TIME:00:20:00 0010.0010 STEP TEMPL=800 0010.0015 STEP TEMPC=800 0010.0020 STEP TEMPS=800 0010.0025 STEP UNLOAD=OFF 0010.0030 STEP LOAD=ON 0010.0035 STEP SPEED=10 0010.0040 STEP TCU CTLID=1 0010.0045 STEP TCU LEARN=OFF 0015.0000 STEAM 0015.0005 STEP TIME:VARIABLE 0015.0010 STEP H2/O2=150 0015.0015 STEP N2=VARIABLE 0015.0020 STEP O2HI=VARIABLE 0015.0025 STEP TCU CTLID=20 0015.0030 STEP TCU LEARN=OFF 0020.0000 DRY OX 0020.0005 STEP TIME:00:02:00 0020.0010 STEP H2/O2=OFF 0020.0015 STEP H2/O2=0 0020.0020 STEP N2=OFF 0020.0025 STEP N2=0 0020.0030 STEP O2HI=2500 0020.0035 STEP TCU CTLID=1 0020.0040 STEP TCU LEARN=OFF 0025.0000 RAMP DOWN 0025.0005 STEP TIME:00:03:00 0025.0010 STEP O2HI=OFF 0025.0015 STEP O2HI=0 0025.0020 STEP N2=ON 0025.0025 STEP N2=5.0 0025.0030 STEP TEMPL=750 0025.0035 STEP TEMPC=750 0025.0040 STEP TEMPS=750 0025.0045 STEP TCU LEARN=OFF 0030.0000 BOAT OUT 0030.0005 STEP TIME:00:00:00 0030.0010 STEP TEMPL=700 0030.0015 STEP TEMPC=750 0030.0020 STEP TEMPS=775 0030.0025 STEP TCU LEARN=OFF 0030.0030 STEP LOAD=OFF 0030.0035 STEP UNLOAD=ON 0030.0040 STEP SPEED=10 0030.0045 STEP IF ALMACK=ON GOTO 0035 0035.0000 END 0035.0005 STEP END PROCESS