PROCESS ID: POLTRAIN DESCRIPTION: POLY FURNACE TRAINING RECIPE ASW 8/3/99 BANK: 3 TUBES: 9 REUSE: YES 0001.0000 IDLE 0001.0005 STEP VACUUM=OFF 0001.0010 STEP N2PURG=2000 0001.0015 STEP TEMPL=590 0001.0020 STEP TEMPC=590 0001.0025 STEP TEMPS=590 0001.0030 STEP UNLOAD=OFF 0001.0035 STEP LOAD=ON 0001.0040 STEP SPEED=25 0001.0045 STEP TCU LEARN=OFF 0005.0000 BOAT OUT 0005.0005 STEP TIME:00:00:00 0005.0010 STEP N2PURG=3500 0005.0015 STEP TEMPL=580 0005.0020 STEP TEMPC=585 0005.0025 STEP TEMPS=590 0005.0030 STEP LOAD=OFF 0005.0035 STEP UNLOAD=ON 0005.0040 STEP SPEED=25 0005.0045 STEP IF ALMACK=ON GOTO 0010 0005.0050 STEP TCU LEARN=OFF 0010.0000 BOAT IN 0010.0005 STEP TIME:00:00:00 0010.0010 STEP TEMPL=600 0010.0015 STEP TEMPC=600 0010.0020 STEP TEMPS=600 0010.0025 STEP UNLOAD=OFF 0010.0030 STEP LOAD=ON 0010.0035 STEP SPEED=25 0010.0040 STEP TCU CTLID=1 0010.0045 STEP TCU LEARN=OFF 0010.0050 STEP IF DNTLK=ON GOTO 0015 0015.0000 INITIAL PUMPDOWN 0015.0005 STEP TIME:00:03:00 0015.0010 STEP N2PURG=300 0015.0015 STEP VACUUM=ON 0015.0020 STEP TEMPL=617.0 0015.0025 STEP TEMPC=620.0 0015.0030 STEP TEMPS=623.0 0015.0035 STEP TCU CTLID=2 0015.0040 STEP TCU LEARN=OFF 0020.0000 START PURGE 0020.0005 STEP TIME:00:01:00 0020.0010 STEP N2PURG=150 0020.0015 STEP H2=60 0020.0020 STEP TCU CTLID=2 0020.0025 STEP TCU LEARN=OFF 0025.0000 PUMP DOWN 0025.0005 STEP TIME:00:02:00 0025.0010 STEP N2PURG=OFF 0025.0015 STEP N2PURG=0 0025.0020 STEP H2=0 0025.0025 STEP H2=OFF 0025.0030 STEP TCU CTLID=2 0025.0035 STEP TCU LEARN=OFF 0025.0040 STEP IF TEMPC<580 GOTO 0065 0030.0000 PUMPDOWN AND GROSS LEAK CHECK 0030.0005 STEP TIME:00:01:00 0030.0010 STEP TCU CTLID=2 0030.0015 STEP PRCPR TOLERANCE=1.0 0030.0020 STEP IF PRCPR>500 GOTO 0105 0035.0000 LEAK CHECK 0035.0005 STEP TIME:00:01:00 0035.0010 STEP TCU CTLID=2 0035.0015 STEP VACUUM=OFF 0035.0020 STEP TCU LEARN=OFF 0035.0025 STEP IF PRCPR>60 GOTO 0105 0040.0000 REPUMP 0040.0005 STEP TIME:00:02:00 0040.0010 STEP VACUUM=ON 0040.0015 STEP N2PURG=200 0040.0020 STEP TCU CTLID=2 0040.0025 STEP TCU LEARN=OFF 0045.0000 START FLOW 0045.0005 STEP TIME:00:02:00 0045.0010 STEP N2PURG=135 0045.0015 STEP H2=80 0045.0020 STEP TCU CTLID=2 0045.0025 STEP TCU LEARN=OFF 0050.0000 PRCPR STABLIZE 0050.0005 STEP TIME:00:02:00 0050.0010 STEP PRCPR=400 0050.0015 STEP TCU CTLID=2 0050.0020 STEP TCU LEARN=OFF 0055.0000 *DEPOSITION* 0055.0005 STEP TIME:VARIABLE 0055.0010 STEP N2PURG=OFF 0055.0015 STEP N2PURG=0 0055.0020 STEP SIH4=136 0055.0025 STEP H2=110 0055.0030 STEP TCU CTLID=2 0055.0035 STEP TCU LEARN=OFF 0055.0040 STEP IF PRCPR>1200 GOTO 0065 0060.0000 H2 PURGE 0060.0005 STEP TIME:00:00:30 0060.0010 STEP SIH4=0 0060.0015 STEP SIH4=OFF 0060.0020 STEP TCU CTLID=3 0060.0025 STEP TCU LEARN=OFF 0060.0030 STEP IF PRCPR>1200 GOTO 0065 0065.0000 1ST PUMP DOWN 0065.0005 STEP TIME:00:03:00 0065.0010 STEP SIH4=OFF 0065.0015 STEP SIH4=0 0065.0020 STEP H2=OFF 0065.0025 STEP H2=0 0065.0030 STEP PRCPR=OFF 0065.0035 STEP PRCPR=0 0065.0040 STEP TEMPL=500 0065.0045 STEP TEMPC=500 0065.0050 STEP TEMPS=500 0065.0055 STEP TCU LEARN=OFF 0070.0000 1ST PURGE 0070.0005 STEP TIME:00:01:00 0070.0010 STEP N2PURG=300 0070.0015 STEP TCU LEARN=OFF 0075.0000 2ND PUMPDOWN 0075.0005 STEP TIME:00:01:00 0075.0010 STEP N2PURG=OFF 0075.0015 STEP N2PURG=0 0075.0020 STEP TCU LEARN=OFF 0080.0000 2ND PURGE 0080.0005 STEP TIME:00:01:00 0080.0010 STEP N2PURG=350 0080.0015 STEP TCU LEARN=OFF 0085.0000 PUMP DOWN 0085.0005 STEP TIME:00:01:00 0085.0010 STEP N2PURG=OFF 0085.0015 STEP N2PURG=0 0085.0020 STEP TCU LEARN=OFF 0090.0000 3RD PURGE 0090.0005 STEP TIME:00:01:00 0090.0010 STEP N2PURG=350 0090.0015 STEP TCU LEARN=OFF 0095.0000 FINAL PUMP DOWN 0095.0005 STEP TIME:00:01:00 0095.0010 STEP N2PURG=OFF 0095.0015 STEP N2PURG=0 0095.0020 STEP TCU LEARN=OFF 0100.0000 FINAL PURGE AND RAMPDOWN 0100.0005 STEP TIME:00:00:00 0100.0010 STEP N2PURG=400 0100.0015 STEP TEMPL TOLERANCE=1.0 0100.0020 STEP IF TEMPL<600 GOTO 0105 0100.0025 STEP TCU LEARN=OFF 0105.0000 SLOW BACKFILL AND ABORT STEP 0105.0005 STEP TIME:00:08:00 0105.0010 STEP VACUUM=OFF 0105.0015 STEP TEMPL=550 0105.0020 STEP TEMPC=550 0105.0025 STEP TEMPS=550 0105.0030 STEP N2PURG=2250 0105.0035 STEP N2BKFL=750 0105.0040 STEP TCU LEARN=OFF 0110.0000 BOAT OUT 0110.0005 STEP TIME:00:00:00 0110.0010 STEP N2BKFL=OFF 0110.0015 STEP N2BKFL=0 0110.0020 STEP N2PURG=3500 0110.0025 STEP TEMPL=500 0110.0030 STEP TEMPC=525 0110.0035 STEP TEMPS=550 0110.0040 STEP LOAD=OFF 0110.0045 STEP UNLOAD=ON 0110.0050 STEP SPEED=25 0110.0055 STEP IF ALMACK=ON GOTO 0115 0110.0060 STEP TCU LEARN=OFF 0115.0000 END 0115.0005 STEP END PROCESS