PROCESS ID: POLY575 DESCRIPTION: POLY DEP AT 575 DEG ST BANK: 2 TUBES: 8 REUSE: YES 0001.0000 IDLE 0001.0005 STEP VACUUM=OFF 0001.0010 STEP N2/AR=3000 0001.0015 STEP TEMPL=590 0001.0020 STEP TEMPC=590 0001.0025 STEP TEMPS=590 0001.0030 STEP UNLOAD=OFF 0001.0035 STEP LOAD=ON 0001.0040 STEP SPEED=25 0001.0045 STEP TCU LEARN=OFF 0005.0000 BOAT OUT 0005.0005 STEP TIME:00:00:00 0005.0010 STEP TEMPL=580 0005.0015 STEP TEMPC=585 0005.0020 STEP TEMPS=590 0005.0025 STEP LOAD=OFF 0005.0030 STEP UNLOAD=ON 0005.0035 STEP SPEED=25 0005.0040 STEP IF ALMACK=ON GOTO 0010 0005.0045 STEP TCU LEARN=OFF 0010.0000 BOAT IN 0010.0005 STEP TIME:00:00:00 0010.0010 STEP TEMPL=600 0010.0015 STEP TEMPC=600 0010.0020 STEP TEMPS=600 0010.0025 STEP UNLOAD=OFF 0010.0030 STEP LOAD=ON 0010.0035 STEP SPEED=25 0010.0040 STEP TCU CTLID=1 0010.0045 STEP TCU LEARN=OFF 0010.0050 STEP IF DNTLK=ON GOTO 0015 0015.0000 INITIAL PUMPDOWN 0015.0005 STEP TIME:00:03:00 0015.0010 STEP N2/AR=300 0015.0015 STEP VACUUM=ON 0015.0020 STEP TEMPL=575 0015.0025 STEP TEMPC=575 0015.0030 STEP TEMPS=575 0015.0035 STEP TCU CTLID=6 0015.0040 STEP TCU LEARN=OFF 0020.0000 START PURGE 0020.0005 STEP TIME:00:01:00 0020.0010 STEP H2=60 0020.0015 STEP TCU CTLID=6 0020.0020 STEP TCU LEARN=OFF 0025.0000 STABILZE 0025.0005 STEP TIME:00:05:00 0025.0010 STEP TCU CTLID=6 0025.0015 STEP TCU LEARN=OFF 0025.0020 STEP IF PRCPR>1200 GOTO 0075 0030.0000 PUMP DOWN 0030.0005 STEP TIME:00:02:00 0030.0010 STEP N2/AR=OFF 0030.0015 STEP N2/AR=0 0030.0020 STEP H2=0 0030.0025 STEP H2=OFF 0030.0030 STEP TCU CTLID=6 0030.0035 STEP TCU LEARN=OFF 0035.0000 PUMPDOWN AND GROSS LEAK CHECK 0035.0005 STEP TIME:00:01:00 0035.0010 STEP TCU CTLID=6 0035.0015 STEP PRCPR TOLERANCE=1.0 0035.0020 STEP IF PRCPR>500 GOTO 0115 0040.0000 LEAK CHECK 0040.0005 STEP TIME:00:01:00 0040.0010 STEP TCU CTLID=6 0040.0015 STEP VACUUM=OFF 0040.0020 STEP TCU LEARN=OFF 0040.0025 STEP IF PRCPR>60 GOTO 0115 0045.0000 REPUMP 0045.0005 STEP TIME:00:02:00 0045.0010 STEP VACUUM=ON 0045.0015 STEP N2/AR=300 0045.0020 STEP TCU CTLID=6 0045.0025 STEP TCU LEARN=OFF 0050.0000 START FLOW 0050.0005 STEP TIME:00:02:00 0050.0010 STEP H2=80 0050.0015 STEP TCU CTLID=6 0050.0020 STEP TCU LEARN=OFF 0055.0000 PRCPR STABLIZE 0055.0005 STEP TIME:00:02:00 0055.0010 STEP PRCPR=VARIABLE 0055.0015 STEP TCU CTLID=6 0055.0020 STEP TCU LEARN=OFF 0060.0000 FINAL STABILIZE TO +-1 DEG 0060.0005 STEP TIME:00:45:00 0060.0010 STEP H2=110 0060.0015 STEP TCU CTLID=6 0060.0020 STEP TCU LEARN=OFF 0060.0025 STEP IF PRCPR>1200 GOTO 0075 0065.0000 *DEPOSITION* 0065.0005 STEP TIME:VARIABLE 0065.0010 STEP N2/AR=OFF 0065.0015 STEP N2/AR=0 0065.0020 STEP SIH4=VARIABLE 0065.0025 STEP H2=VARIABLE 0065.0030 STEP TCU CTLID=6 0065.0035 STEP TCU LEARN=OFF 0065.0040 STEP IF PRCPR>1200 GOTO 0075 0070.0000 H2 PURGE 0070.0005 STEP TIME:00:00:30 0070.0010 STEP SIH4=0 0070.0015 STEP SIH4=OFF 0070.0020 STEP TCU LEARN=OFF 0070.0025 STEP IF PRCPR>1200 GOTO 0075 0075.0000 1ST PUMP DOWN 0075.0005 STEP TIME:00:03:00 0075.0010 STEP SIH4=OFF 0075.0015 STEP SIH4=0 0075.0020 STEP H2=OFF 0075.0025 STEP H2=0 0075.0030 STEP PRCPR=OFF 0075.0035 STEP PRCPR=0 0075.0040 STEP TEMPL=500 0075.0045 STEP TEMPC=500 0075.0050 STEP TEMPS=500 0075.0055 STEP TCU LEARN=OFF 0080.0000 1ST PURGE 0080.0005 STEP TIME:00:01:00 0080.0010 STEP N2/AR=300 0080.0015 STEP TCU LEARN=OFF 0085.0000 2ND PUMPDOWN 0085.0005 STEP TIME:00:01:00 0085.0010 STEP N2/AR=OFF 0085.0015 STEP N2/AR=0 0085.0020 STEP TCU LEARN=OFF 0090.0000 2ND PURGE 0090.0005 STEP TIME:00:01:00 0090.0010 STEP N2/AR=300 0090.0015 STEP TCU LEARN=OFF 0095.0000 PUMP DOWN 0095.0005 STEP TIME:00:01:00 0095.0010 STEP N2/AR=OFF 0095.0015 STEP N2/AR=0 0095.0020 STEP TCU LEARN=OFF 0100.0000 3RD PURGE 0100.0005 STEP TIME:00:01:00 0100.0010 STEP N2/AR=350 0100.0015 STEP TCU LEARN=OFF 0105.0000 FINAL PUMP DOWN 0105.0005 STEP TIME:00:01:00 0105.0010 STEP N2/AR=OFF 0105.0015 STEP N2/AR=0 0105.0020 STEP TCU LEARN=OFF 0110.0000 FINAL PURGE AND RAMPDOWN 0110.0005 STEP TIME:00:00:00 0110.0010 STEP N2/AR=400 0110.0015 STEP TEMPL TOLERANCE=1.0 0110.0020 STEP IF TEMPL<600 GOTO 0115 0110.0025 STEP TCU LEARN=OFF 0115.0000 SLOW BACKFILL AND ABORT STEP 0115.0005 STEP TIME:00:08:00 0115.0010 STEP VACUUM=OFF 0115.0015 STEP TEMPL=550 0115.0020 STEP TEMPC=550 0115.0025 STEP TEMPS=550 0115.0030 STEP N2/AR=2500 0115.0035 STEP N2BKFL=750 0115.0040 STEP TCU LEARN=OFF 0120.0000 BOAT OUT 0120.0005 STEP TIME:00:00:00 0120.0010 STEP N2BKFL=OFF 0120.0015 STEP N2BKFL=0 0120.0020 STEP TEMPL=500 0120.0025 STEP TEMPC=525 0120.0030 STEP TEMPS=550 0120.0035 STEP LOAD=OFF 0120.0040 STEP UNLOAD=ON 0120.0045 STEP SPEED=25 0120.0050 STEP IF ALMACK=ON GOTO 0125 0120.0055 STEP TCU LEARN=OFF 0125.0000 END 0125.0005 STEP END PROCESS