Uniformity Testing Procedure for Tylanpoly
Purpose: To provide a standard procedure to monitor Poly
thickness and uniformity both wafer-to-wafer and within-a-wafer.
Frequency of test: to be completed after major maintenance
such as a tube change or on a set schedule to be determined or as needed based
on user feedback.
Documentation of results: to be posted in hardcopy
in the Uniformity Test Book located in the lab, posted in the email archive for
the specific furnace and keep in process/maintenance group internal
spreadsheet.
Procedure:
Use
four wafers with 1000A of SiO2.
Clean at wbdiff in the
following sequence; 4:1 H2SO4:H2O2 ten minutes, rinse, 5:1:1 DI;HCl:H2O2 ten
minutes, rinse, spin dry.
Load
program POLYEMIT into Tylanpoly furnace.
Time variable is 00:15:00.
Load wafers into boats using
very clean tweezers or vacuum wand.
Load wafers with the major flat up into the boats in the following
positions:
1st boat:
(Front), 20 empty slots,
1st two dummies,
1st boat: two test wafers(slot 23 & 24),
1st boat: one
dummy.
2nd boat: one dummy,
2nd boat: two test wafers (slot 2 &3),
2nd boat one dummy, 21 empty slots.
Use Nanospec to measure poly
thickness at the flat, center, bottom, left and right on each wafer. Test sites should be no more than about 15mm
from the edge of the wafer.
Record results on the Uniformity Testing Form and
post to appropriate email and spreadsheets. If test’s values aren’t not within
10% of plotted test average, contact the Diffusion Process/Maintenance team.
Save wafers in a box with the date, furnace number,
program name and growth time. They may
be re-tested sometime in the future.