01:
Problem tylan2: Tl indicates 400c during 1000c process
(
price.snf.stanford.edu
)
02:
Problem Clear tylan2: reset themocouple connection
(
gaul.snf.stanford.edu
)
03:
Problem tylan2: Load side of hot zone bad; Ox thickness from source to load varies 1000A.
(
latta.snf.stanford.edu
)
04:
Problem Clear tylan2: Reset t/c connection
(
gaul.snf.stanford.edu
)
05:
Problem tylan2:
(
pzwahlen.snf.stanford.edu
)
06:
Problem Clear tylan2: not sure of problem
(
gaul.snf.stanford.edu
)
07:
Shutdown tylan2: loader sheath needs to be replaced
(
seymour.snf.stanford.edu
)
08:
Shutdown tylan2: TCA clean started
(
seymour.snf.stanford.edu
)
09:
Problem tylan2: Loader stops as pushing into tube.
(
latta.snf.stanford.edu
)
10:
Re: Problem tylan2 2000-12-05 11:41:51: Loader stops as pushing into tube.
(
latta.snf.stanford.edu
)
11:
Problem tylan2 2001-01-21 01:55:44: Typical ox growth yielded 18.9A where it has always given 205A (Temp was correct)
(
dhelqaq.snf.stanford.edu
)
12:
Re: Problem tylan2 2001-01-21 01:55:44: Checked furnace operation
(
seymour.snf.stanford.edu
)
13:
Problem tylan2 2001-01-25 10:59:51: tylan2 stuck
(
april.snf.stanford.edu
)
14:
Shutdown tylan2 2001-01-25 11:46:27: loader bearings
(
seymour.snf.stanford.edu
)
15:
Re: Problem tylan2 2001-01-25 10:59:51: tylan2 stuck
(
seymour.snf.stanford.edu
)
16:
Re: Shutdown tylan2 2001-01-25 11:46:27: loader bearings
(
seymour.snf.stanford.edu
)
17:
Shutdown tylan2 2001-01-27 16:29:04: right side of back baffle was dragging along tube and was pushing the boats to the front. boats were put in orange dry box
(
dhelqaq.snf.stanford.edu
)
18:
Re: Shutdown tylan2 2001-01-27 16:29:04: Back up for production!
(
jgarate.snf.stanford.edu
)
19:
Problem tylan2 2001-02-08 07:51:55: 2 TC's have small "b"
(
lindaw.snf.stanford.edu
)
20:
Re: Problem tylan2 2001-02-08 07:51:55: 2 TC's have small "b" not any more
(
seymour.snf.stanford.edu
)
21:
Problem tylan2 2001-03-13 10:28:43: small "b" on center TC
(
lindaw.snf.stanford.edu
)
22:
Re: Problem tylan2 2001-03-13 10:28:43: small "b" on center TC
(
seymour.snf.stanford.edu
)
23:
Shutdown tylan2 2001-04-11 11:15:28: tylan2
(
gsarmien.snf.stanford.edu
)
24:
Re: Shutdown tylan2 2001-04-11 11:15:28: tylan2
(
gsarmien.snf.stanford.edu
)
25:
Re: Shutdown tylan2 2001-04-11 11:15:28: tylan2
(
gsarmien.snf.stanford.edu
)
26:
Problem tylan2 2001-05-03 17:38:23: Bad T/C, LOAD end
(
qwang.snf.stanford.edu
)
27:
Shutdown tylan2 2001-05-04 07:59:26: changing profile t/c
(
seymour.snf.stanford.edu
)
28:
Re: Problem tylan2 2001-05-03 17:38:23: Bad T/C, LOAD end
(
mdickey.snf.stanford.edu
)
29:
Re: Shutdown tylan2 2001-05-04 07:59:26: changing profile t/c
(
mdickey.snf.stanford.edu
)
30:
Problem tylan2 2001-05-29 00:03:19: bad backup t/c (tycom shows 'b')
(
rohits.snf.stanford.edu
)
31:
Shutdown tylan2 2001-05-31 02:31:25: TEMPL=400C. TCU problem.
(
amol.snf.stanford.edu
)
32:
Re: Shutdown tylan2 2001-05-31 02:31:25: TEMPL=400C. TCU problem.
(
seymour.snf.stanford.edu
)
33:
Re: Problem tylan2 2001-05-29 00:03:19: bad backup t/c (tycom shows 'b')
(
seymour.snf.stanford.edu
)
34:
Shutdown tylan2 2001-05-31 08:46:12: test only
(
rcrane.snf.stanford.edu
)
35:
Shutdown tylan2 2001-05-31 08:50:21: test only
(
rcrane.snf.stanford.edu
)
36:
Re: Shutdown tylan2 2001-05-31 08:50:21: test only
(
rcrane.snf.stanford.edu
)
37:
Re: Shutdown tylan2 2001-05-31 08:46:12: test only
(
rcrane.snf.stanford.edu
)
38:
Shutdown tylan2 2001-05-31 08:51:36: test only
(
rcrane.snf.stanford.edu
)
39:
Re: Shutdown tylan2 2001-05-31 08:51:36: test only
(
rcrane.snf.stanford.edu
)
40:
Shutdown tylan2 2001-05-31 12:08:30: test two
(
rcrane.snf.stanford.edu
)
41:
Shutdown tylan2 2001-05-31 12:10:21: test 3
(
rcrane.snf.stanford.edu
)
42:
Re: Shutdown tylan2 2001-05-31 12:08:30: test two
(
rcrane.snf.stanford.edu
)
43:
Re: Shutdown tylan2 2001-05-31 12:10:21: test 3
(
rcrane.snf.stanford.edu
)
44:
Shutdown tylan2 2001-05-31 12:12:07: test 4
(
rcrane.snf.stanford.edu
)
45:
Re: Shutdown tylan2 2001-05-31 12:12:07: test 4
(
rcrane.snf.stanford.edu
)
46:
Problem tylan2 2001-07-18 16:03:19: tylan2 temps has a backup tc prob
(
gladys.snf.stanford.edu
)
47:
Re: Problem tylan2 2001-07-18 16:03:19: tylan2 temps has a backup tc prob
(
seymour.snf.stanford.edu
)
48:
Shutdown tylan2 2001-08-25 07:37:23:
(
seymour.snf.stanford.edu
)
49:
Shutdown tylan2 2001-08-25 07:37:29:
(
seymour.snf.stanford.edu
)
50:
Re: Shutdown tylan2 2001-08-25 07:37:29:
(
seymour.snf.stanford.edu
)
51:
Re: Shutdown tylan2 2001-08-25 07:37:23:
(
seymour.snf.stanford.edu
)
52:
Problem tylan2 2001-10-01 11:48:23: tylan2: Output flows are all showing B/b errors
(
gladys.snf.stanford.edu
)
53:
Re: Problem tylan2 2001-10-01 11:48:23: tylan2: Output flows are all showing B/b errors
(
seymour.snf.stanford.edu
)
54:
Comment tylan2 2001-11-02 12:04:40: 11/1/01 Uniformity
(
ejwong.snf.stanford.edu
)
55:
Shutdown tylan2 2002-02-05 17:09:57: Tylan Bank 1 move
(
gladys.snf.stanford.edu
)
56:
Re: Shutdown tylan2 2002-03-08 17:33:58: Oxidation failure
(
seymour.snf.stanford.edu
)
57:
Re: Problem tylan2 2002-03-08 17:11:36: Wrong oxide thickness growth
(
seymour.snf.stanford.edu
)
58:
Problem tylan2 2002-04-23 18:46:28: Wafer piece inside the tube
(
vossough.snf.stanford.edu
)
59:
Re: Problem tylan2 2002-04-23 18:46:28: Wafer piece inside the tube
(
mdickey.snf.stanford.edu
)
60:
Problem tylan2 2002-06-01 22:22:42: MFS fault H2
(
ericp.snf.stanford.edu
)
61:
Shutdown tylan2 2002-06-03 07:44:22: H2 flow problem
(
seymour.snf.stanford.edu
)
62:
Re: Problem tylan2 2002-06-01 22:22:42: MFS fault H2
(
seymour.snf.stanford.edu
)
63:
Re: Shutdown tylan2 2002-06-03 07:44:22: H2 flow problem
(
seymour.snf.stanford.edu
)
64:
Shutdown tylan2 2002-06-03 07:57:17: running TCACLEAN
(
seymour.snf.stanford.edu
)
65:
Re: Shutdown tylan2 2002-06-03 07:57:17: running TCACLEAN: testrun completed, ok to use
(
gladys.snf.stanford.edu
)
66:
Shutdown tylan2 2002-06-05 08:29:24: checking gas lines
(
seymour.snf.stanford.edu
)
67:
Re: Shutdown tylan2 2002-06-05 08:29:24: checking gas lines
(
seymour.snf.stanford.edu
)
68:
Problem tylan2 2002-06-17 13:29:59: Bad load thermal couple
(
liux.snf.stanford.edu
)
69:
Re: Problem tylan2 2002-06-17 13:29:59: Bad load thermal couple
(
seymour.snf.stanford.edu
)
70:
Problem tylan2 2002-07-05 11:34:23: TEACLEAN due to possible glass contamination
(
ychliu.snf.stanford.edu
)
71:
Re: Problem tylan2 2002-07-05 11:34:23: TEACLEAN due to possible glass contamination
(
seymour.snf.stanford.edu
)
72:
Problem tylan2 2002-08-22 22:10:26: MFS keeps alarming
(
yyao.snf.stanford.edu
)
73:
Re: Problem tylan2 2002-08-22 22:10:26: MFS keeps alarming
(
seymour.snf.stanford.edu
)
74:
Problem tylan2 2002-08-27 20:00:35: H2 Fault --Can not run Steam
(
mcvittie.snf.stanford.edu
)
75:
Re: Problem tylan2 2002-08-27 20:00:35: H2 Fault --Can not run Steam
(
seymour.snf.stanford.edu
)
76:
Use of Steam in Ox Furnaces
(
Mary Tang
)
77:
Problem tylan2 2002-08-28 19:27:56: Please do not use steam ox, til further notice
(
mtang.snf.stanford.edu
)
78:
Re: Problem tylan2 2002-08-28 19:27:56: Please do not use steam ox, til further notice
(
mcvittie.snf.stanford.edu
)
79:
Problem tylan2 2002-09-01 14:59:23: See Ty#1 Equip Email Achiev Note on TCA
(
mcvittie.snf.stanford.edu
)
80:
Shutdown tylan2 2002-09-06 13:19:22: doing some quick checks on gas lines
(
seymour.snf.stanford.edu
)
81:
Re: Shutdown tylan2 2002-09-06 13:19:22: doing some quick checks on gas lines
(
seymour.snf.stanford.edu
)
82:
Problem tylan2 2002-09-10 12:31:12: TEMPL reading 400C (used 1100C)
(
latta.snf.stanford.edu
)
83:
Shutdown tylan2 2002-09-11 15:33:19: checking H2/TCA and O2 lines
(
seymour.snf.stanford.edu
)
84:
Shutdown tylan2 2002-09-16 09:52:27: Pull and clean
(
mdickey.snf.stanford.edu
)
85:
Re: Shutdown tylan2 2002-09-16 09:52:27: Pull and clean
(
seymour.snf.stanford.edu
)
86:
Re: Shutdown tylan2 2002-09-11 15:33:19: checking H2/TCA and O2 lines
(
seymour.snf.stanford.edu
)
87:
Re: Problem tylan2 2002-09-10 12:31:12: TEMPL reading 400C (used 1100C)
(
seymour.snf.stanford.edu
)
88:
Shutdown tylan2 2002-09-18 13:27:33: Needs test after repair
(
seymour.snf.stanford.edu
)
89:
Re: Shutdown tylan2 2002-09-18 13:27:33: Needs test after repair
(
latta.snf.stanford.edu
)
90:
Re: Problem tylan2 2002-09-01 14:59:23: See Ty#1 Equip Email Achiev Note on TCA
(
latta.snf.stanford.edu
)
91:
Shutdown tylan2 2002-10-01 16:08:28: H2/O2 leak during NEWTCA
(
latta.snf.stanford.edu
)
92:
Re: Shutdown tylan2 2002-10-01 16:08:28: H2/O2 leak during NEWTCA
(
seymour.snf.stanford.edu
)
93:
Shutdown tylan2 2002-10-03 09:24:03: Needs test after repair
(
seymour.snf.stanford.edu
)
94:
Re: Shutdown tylan2 2002-10-03 09:24:03: Needs test after repair
(
latta.snf.stanford.edu
)
95:
Test
(
Nancy Latta
)
96:
Uniformity monitor test results
(
Nancy Latta
)
97:
Re: Uniformity monitor test results
(
Jim McVittie
)
98:
Re: Uniformity monitor test results
(
Nancy Latta
)
99:
Problem tylan2 2002-11-20 09:56:48: TCA Temp too High
(
tberg.snf.stanford.edu
)
[<<-]
[<-]
[->]
[->>]
|