01: Shutdown tylan6: Test (bmurray.snf.stanford.edu)
02: Shutdown Clear tylan6: (bmurray.snf.stanford.edu)
03: Shutdown tylan6: Door Opens w/ baffle left behind (hansen.snf.stanford.edu)
04: Comment tylan6: found bad source temp controller (seymour.snf.stanford.edu)
05: Re: Shutdown tylan6 2000-11-29 16:32:47: Back up for production (jgarate.snf.stanford.edu)
06: Shutdown tylan6 2001-01-22 10:03:29: TCU Error: 80 (mbadi.snf.stanford.edu)
07: Re: Shutdown tylan6 2001-01-22 10:03:29: TCU Error: 80 (seymour.snf.stanford.edu)
08: Shutdown tylan6 2001-02-06 02:45:37: Door lock not working (mayur.snf.stanford.edu)
09: Re: Shutdown tylan6 2001-02-06 02:45:37: Door lock not working (seymour.snf.stanford.edu)
10: Shutdown tylan6 2001-04-17 10:17:16: I/O error (seymour.snf.stanford.edu)
11: Re: Shutdown tylan6 2001-04-17 10:17:16: I/O error (seymour.snf.stanford.edu)
12: Shutdown tylan6 2001-06-28 15:30:55: tylan6: door interlock won't turn on (gsarmien.snf.stanford.edu)
13: Re: Shutdown tylan6 2001-06-28 15:30:55: tylan6:will do a testrun (gladys.snf.stanford.edu)
14: Shutdown tylan6 2001-08-25 07:38:09: (seymour.snf.stanford.edu)
15: Re: Shutdown tylan6 2001-08-25 07:38:09: (seymour.snf.stanford.edu)
16: Shutdown tylan6 2001-09-24 08:13:59: tube turned off when tube 8 failed (seymour.snf.stanford.edu)
17: Re: Shutdown tylan6 2001-09-24 08:13:59: tube turned off when tube 8 failed: testrun was ok (gladys.snf.stanford.edu)
18: Shutdown tylan6 2002-01-09 17:25:57: I / 0 ERROR (gladys.snf.stanford.edu)
19: Re: Shutdown tylan6 2002-01-09 17:25:57: I / 0 ERROR (seymour.snf.stanford.edu)
20: Problem tylan6 2002-01-15 16:50:53: tylan6: door seal may be coated (liji.snf.stanford.edu)
21: Shutdown tylan6 2002-01-29 07:31:07: checking system (seymour.snf.stanford.edu)
22: Re: Shutdown tylan6 2002-01-29 07:31:07: checking systemits ok (seymour.snf.stanford.edu)
23: Re: Problem tylan6 2002-01-15 16:50:53: tylan6: door seal may be coated (seymour.snf.stanford.edu)
24: Shutdown tylan6 2002-03-19 06:30:20: gas line redo (tberg.snf.stanford.edu)
25: Re: Shutdown tylan6 2002-03-19 06:30:20: gas line redo (tberg.snf.stanford.edu)
26: Shutdown tylan6 2002-03-26 12:19:00: Heating element cold. (latta.snf.stanford.edu)
27: Re: Shutdown tylan6 2002-03-26 12:19:00: Heating element cold. (seymour.snf.stanford.edu)
28: Problem tylan6 2002-03-27 15:04:35: Door doesnot open automatically at the end of process (liji.snf.stanford.edu)
29: Shutdown tylan6 2002-03-27 23:06:37: broken quartz inside the tube and paddle is tilted down (cbaxter.snf.stanford.edu)
30: Re: Shutdown tylan6 2002-03-27 23:06:37: broken quartz inside the tube and paddle is tilted down (seymour.snf.stanford.edu)
31: Re: Problem tylan6 2002-03-27 15:04:35: Door doesnot open automatically at the end of process (seymour.snf.stanford.edu)
32: Shutdown tylan6 2002-04-25 14:21:13: POCL3 empty (liji.snf.stanford.edu)
33: Re: Shutdown tylan6 2002-04-25 14:21:13: POCL3 empty (tberg.snf.stanford.edu)
34: Shutdown tylan6 2002-04-29 16:33:27: waiting for testrun (gladys.snf.stanford.edu)
35: Re: Shutdown tylan6 2002-04-29 16:33:27: waiting for testrun: run completed...ok to use (gladys.snf.stanford.edu)
36: Shutdown tylan6 2002-05-03 10:28:02: Source control (mdickey.snf.stanford.edu)
37: Re: Shutdown tylan6 2002-05-03 10:28:02: Source control (seymour.snf.stanford.edu)
38: Shutdown tylan6 2002-05-13 07:34:34: MFS460 controller not working correctly (seymour.snf.stanford.edu)
39: Problem tylan6 2002-05-22 19:23:10: MSF alarm at ~19:00; controller not working? (liji.snf.stanford.edu)
40: Shutdown tylan6 2002-05-23 07:34:07: MSF460 controller alarming (seymour.snf.stanford.edu)
41: Re: Shutdown tylan6 2002-05-23 07:34:07: MSF460 controller alarming (seymour.snf.stanford.edu)
42: Re: Problem tylan6 2002-05-22 19:23:10: MSF alarm at ~19:00; controller not working? (seymour.snf.stanford.edu)
43: Shutdown tylan6 2002-05-23 10:50:24: Needs test after repair (seymour.snf.stanford.edu)
44: Re: Shutdown tylan6 2002-05-23 10:50:24: Needs test after repair: test completed, ok to use (gladys.snf.stanford.edu)
45: Shutdown tylan6 2002-09-17 22:53:02: POCl3 leak (cbaxter.snf.stanford.edu)
46: Re: Shutdown tylan6 2002-09-17 22:53:02: POCl3 leak (rcrane.snf.stanford.edu)
47: Shutdown tylan6 2002-11-07 17:54:59: POCl3 bubbler manually valved off (shott.snf.stanford.edu)
48: Re: Shutdown tylan6 2002-11-07 17:54:59: POCl3 bubbler manually valved off (tberg.snf.stanford.edu)
49: Re: Problem tylan6 2002-11-11 18:20:39: Door interlock not on (seymour.snf.stanford.edu)
50: Shutdown tylan6 2003-01-27 06:57:09: POCOL change (mdickey.snf.stanford.edu)
51: Re: Shutdown tylan6 2003-01-27 06:57:09: POCOL change (tberg.snf.stanford.edu)
52: Problem tylan6 2003-01-27 07:27:41: changed cannister (tberg.snf.stanford.edu)
53: Shutdown tylan6 2003-01-27 08:50:24: needs test after POCl3 change (seymour.snf.stanford.edu)
54: Re: Problem tylan6 2003-01-27 07:27:41: changed cannister (seymour.snf.stanford.edu)
55: Re: Shutdown tylan6 2003-01-27 08:50:24: needs test after POCl3 change (seymour.snf.stanford.edu)
56: Problem tylan6 2003-02-28 13:55:34: Report Problem for tylan6 (seymour.snf.stanford.edu)
57: Shutdown tylan6 2003-03-13 06:39:59: Report Shutdown for tylan6 (tberg.snf.stanford.edu)
58: Re: Problem tylan6 2003-02-28 13:55:34: Report Clear for tylan6 (seymour.snf.stanford.edu)
59: Re: Shutdown tylan6 2003-03-13 06:39:59: Report Clear for tylan6 (seymour.snf.stanford.edu)
60: Shutdown tylan6 2003-12-12 06:46:11: Bank Shut down for TEOS retro (tberg.snf.stanford.edu)
61: Re: Shutdown tylan6 2003-12-12 06:46:11: Bank Shut down for TEOS retro (gladys.snf.stanford.edu)
62: Problem tylan6 2004-01-08 14:19:17: testrun completed, waiting for the resistivity measurement. (gladys.snf.stanford.edu)
63: Shutdown tylan6 2004-01-09 13:47:00: Report Shutdown for tylan6 (mdickey.snf.stanford.edu)
64: Re: Shutdown tylan6 2004-01-09 13:47:00: Report Shutdown for tylan6 (seymour.snf.stanford.edu)
65: Re: Problem tylan6 2004-01-08 14:19:17: testrun completed, waiting for the resistivity measurement. (seymour.snf.stanford.edu)
66: Shutdown tylan6 2004-01-14 11:15:44: needs test after tube change (seymour.snf.stanford.edu)
67: Re: Shutdown tylan6 2004-01-14 11:15:44: needs test after tube change (seymour.snf.stanford.edu)
68: Problem tylan6 2004-01-15 10:29:02: user will do a test. (seymour.snf.stanford.edu)
69: Re: Problem tylan6 2004-01-15 10:29:02: user will do a test. (gladys.snf.stanford.edu)
70: Shutdown tylan6 2004-02-25 16:21:58: investigating possible gas leak (seymour.snf.stanford.edu)
71: Re: Shutdown tylan6 2004-02-25 16:21:58: investigating possible gas leak (seymour.snf.stanford.edu)
72: Shutdown tylan6 2004-03-29 11:43:04: Tube hot? (kenney.snf.stanford.edu)
73: Re: Shutdown tylan6 2004-03-29 11:43:04: Tube hot? (seymour.snf.stanford.edu)
74: Comment tylan6 2004-03-29 11:57:58: check temp before using (seymour.snf.stanford.edu)
75: Re: Problem tylan6 2004-04-15 17:54:24: residue left on the wafers (gladys.snf.stanford.edu)
76: Shutdown tylan6 SNF 2004-07-28 06:28:43: Source change (mdickey.snf.stanford.edu)
77: Comment tylan6 SNF 2004-07-28 07:10:27: Test (mdickey.snf.stanford.edu)
78: Re: Shutdown tylan6 SNF 2004-07-28 06:28:43: Source change (latta.snf.stanford.edu)
79: Re: Comment tylan6 SNF 2004-07-28 07:10:27: Test (latta.snf.stanford.edu)
80: Shutdown tylan6 SNF 2005-06-20 18:06:17: POCl smell in the lab (ericp.snf.stanford.edu)
81: Re: Shutdown tylan6 SNF 2005-06-20 18:06:17: POCl smell in the lab (seymour.snf.stanford.edu)
82: Problem tylan6 SNF 2005-06-21 11:17:22: needs test after POCL3 source replaced. (seymour.snf.stanford.edu)
83: Re: Problem tylan6 SNF 2005-06-21 11:17:22: needs test after POCL3 source replaced. (seymour.snf.stanford.edu)
84: Problem tylan6 SNF 2005-08-02 21:46:20: the vacuum wand is found damaged (elvislin.snf.stanford.edu)
85: Re: Problem tylan6 SNF 2005-08-02 21:46:20: the vacuum wand is found damaged (mdickey.snf.stanford.edu)
86: Shutdown tylan6 SNF 2005-08-15 06:18:07: Shutdown for bank 4 move (tberg.snf.stanford.edu)
87: Re: Shutdown tylan6 SNF 2005-08-15 06:18:07: Shutdown for bank 4 move (maurice.snf.stanford.edu)
88: Problem tylan6 SNF 2005-09-08 11:39:28: after shutdown...need test (maurice.snf.stanford.edu)
89: Re: Problem tylan6 SNF 2005-09-08 11:39:28: after shutdown...need test (maurice.snf.stanford.edu)
90: Problem tylan6 SNF 2006-01-04 11:07:32: MFS ERROR:01 (gladys.snf.stanford.edu)
91: Re: Problem tylan6 SNF 2006-01-04 11:07:32: MFS ERROR:01 (tberg.snf.stanford.edu)
92: Shutdown tylan6 SNF 2006-01-10 17:07:44: Source Baffle Fell Off (kenney.snf.stanford.edu)
93: Re: Shutdown tylan6 SNF 2006-01-10 17:07:44: Source Baffle Fell Off (mdickey.snf.stanford.edu)
94: Shutdown tylan6 SNF 2006-01-16 15:57:41: Tylan 6 (king.snf.stanford.edu)
95: Re: Shutdown tylan6 SNF 2006-01-16 15:57:41: Tylan 6 (tberg.snf.stanford.edu)
96: Shutdown tylan6 SNF 2006-01-23 14:08:03: I/O error (tberg.snf.stanford.edu)