01:
Problem Clear tylannitride: shutdown for cleaning
(
(none)
)
02:
Shutdown tylannitride: Shutdown for cleaning
(
(none)
)
03:
Problem Clear tylannitride: OK Now
(
(none)
)
04:
Problem tylannitride: dntlk did not go on
(
(none)
)
05:
Shutdown Clear tylannitride: completed
(
(none)
)
06:
Problem Clear tylannitride: reset flag
(
(none)
)
07:
Problem tylannitride: templ backup thermocouple showing up as bad
(
(none)
)
08:
Problem tylannitride: tylannitride t/c b
(
reyrey.snf.stanford.edu
)
09:
Problem Clear tylannitride: same as other problem listed
(
gaul.snf.stanford.edu
)
10:
Problem Clear tylannitride: TC looks fine
(
latta.snf.stanford.edu
)
11:
Problem tylannitride: Squeaking sound near boat puller mechanism...
(
latta.snf.stanford.edu
)
12:
Shutdown tylannitride: pressure in burn box
(
gaul.snf.stanford.edu
)
13:
Shutdown Clear tylannitride: completed
(
gaul.snf.stanford.edu
)
14:
Problem tylannitride: TEMPLb on nitride
(
sylviajs.snf.stanford.edu
)
15:
Problem tylannitride: DCS Flow dropped to zero during dep.
(
ericp.snf.stanford.edu
)
16:
Problem tylannitride: TEMPL giving b, dep. rate is high
(
sanli.snf.stanford.edu
)
17:
Problem Clear tylannitride: Already reported
(
gaul.snf.stanford.edu
)
18:
Problem Clear tylannitride: Alarm in vault caused zero flow
(
gaul.snf.stanford.edu
)
19:
Problem Clear tylannitride: Boat loader motor was on
(
gaul.snf.stanford.edu
)
20:
Problem tylannitride: mfs alarm went off
(
sylviajs.snf.stanford.edu
)
21:
Problem tylannitride: LONH378 films looked non-uniform and splotchy
(
sminne.snf.stanford.edu
)
22:
Problem tylannitride: MFS alarm during PUMP10.
(
latta.snf.stanford.edu
)
23:
Problem tylannitride: "b" on TEMPL TC
(
lindaw.snf.stanford.edu
)
24:
Problem Clear tylannitride: Cleaned out fore line
(
gaul.snf.stanford.edu
)
25:
Problem Clear tylannitride: Cleaned out fore line
(
gaul.snf.stanford.edu
)
26:
Problem Clear tylannitride: redundant problem
(
gaul.snf.stanford.edu
)
27:
Shutdown tylannitride: System requires rebuild
(
wheeler.snf.stanford.edu
)
28:
Shutdown Clear tylannitride: System back up
(
gaul.snf.stanford.edu
)
29:
Problem Clear tylannitride: System has been cleaned
(
gaul.snf.stanford.edu
)
30:
Shutdown tylannitride: Nitride down for Characterization test
(
gaul.snf.stanford.edu
)
31:
Problem Clear tylannitride: Replaced spike T/C
(
gaul.snf.stanford.edu
)
32:
Shutdown Clear tylannitride: Test results O.K.
(
gaul.snf.stanford.edu
)
33:
Comment tylannitride: Canceling my reservation for nitride from 06:00 to 16:00
(
jgarate.snf.stanford.edu
)
34:
Shutdown tylannitride: Down for high Leak Check
(
jgarate.snf.stanford.edu
)
35:
Comment tylannitride:
(
seymour.snf.stanford.edu
)
36:
Shutdown tylannitride: tube clean in process
(
seymour.snf.stanford.edu
)
37:
Shutdown Clear tylannitride:
(
seymour.snf.stanford.edu
)
38:
Shutdown Clear tylannitride: tube ready for conditioning
(
seymour.snf.stanford.edu
)
39:
Problem tylannitride: needs to be conditioned
(
seymour.snf.stanford.edu
)
40:
Shutdown tylannitride: Nitride under Characterization
(
jgarate.snf.stanford.edu
)
41:
Problem Clear tylannitride: Done 10/30/2000
(
jgarate.snf.stanford.edu
)
42:
Shutdown Clear tylannitride: Done, up for production
(
jgarate.snf.stanford.edu
)
43:
Shutdown tylannitride: Run away temp. B tc
(
caudillo.snf.stanford.edu
)
44:
Shutdown Clear tylannitride: system controlling ok at this time, will monitor
(
seymour.snf.stanford.edu
)
45:
Problem tylannitride: Boat won't come out by itselfDate: Nov 16, 2000 5:31:13 PM
(
pzwahlen.snf.stanford.edu
)
46:
Shutdown tylannitride: system shutdownDate: Nov 17, 2000 3:42:04 PM
(
seymour.snf.stanford.edu
)
47:
Problem tylannitride: Boat won't come out by itself
(
rcrane.snf.stanford.edu
)
48:
Shutdown tylannitride: system shutdown
(
rcrane.snf.stanford.edu
)
49:
Problem tylannitride: Only 1 test wafer in the boat
(
pzwahlen.snf.stanford.edu
)
50:
Problem tylannitride: Added the rest of the dummy wafers.
(
jgarate.snf.stanford.edu
)
51:
Shutdown tylannitride:
(
seymour.snf.stanford.edu
)
52:
Shutdown tylannitride: shutdown cleared
(
seymour.snf.stanford.edu
)
53:
Shutdown tylannitride: high leak rate
(
plong.snf.stanford.edu
)
54:
Re: Shutdown tylannitride 2000-12-11 11:10:53: The system leak rate is good system up
(
seymour.snf.stanford.edu
)
55:
Shutdown tylannitride 2000-12-18 07:39:59:
(
seymour.snf.stanford.edu
)
56:
Re: Shutdown tylannitride 2000-12-18 07:39:59: burnbox clean completed ok to run
(
seymour.snf.stanford.edu
)
57:
Shutdown tylannitride 2001-01-12 16:13:15: Diclorsilane Cylinder
(
seymour.snf.stanford.edu
)
58:
Comment tylannitride 2001-01-19 16:04:13: Diclor bottle changed, under pressure test untill Monday AM
(
seymour.snf.stanford.edu
)
59:
Re: Shutdown tylannitride 2001-01-12 16:13:15: Diclorsilane Cylinder
(
seymour.snf.stanford.edu
)
60:
Problem tylannitride 2001-01-24 04:15:16: DCS Failure
(
hlkung.snf.stanford.edu
)
61:
Shutdown tylannitride 2001-01-24 04:16:02: No DCS
(
hlkung.snf.stanford.edu
)
62:
Re: Shutdown tylannitride 2001-01-24 04:16:02: No DCS
(
seymour.snf.stanford.edu
)
63:
Re: Problem tylannitride 2001-01-24 04:15:16: DCS line leak tight.
(
seymour.snf.stanford.edu
)
64:
Problem tylannitride 2001-01-25 18:18:14: DCS Excess Flow Valva
(
shott.snf.stanford.edu
)
65:
Shutdown tylannitride 2001-01-26 10:15:52: Tube is flacking. Down for pull & clean
(
jgarate.snf.stanford.edu
)
66:
Re: Problem tylannitride 2001-01-25 18:18:14: DCS Excess Flow Valva
(
seymour.snf.stanford.edu
)
67:
Re: Shutdown tylannitride 2001-01-26 10:15:52: system up for characterization after clean
(
seymour.snf.stanford.edu
)
68:
Shutdown tylannitride 2001-02-06 10:16:53: Needs to be Coated.
(
jgarate.snf.stanford.edu
)
69:
Problem tylannitride 2001-02-06 11:53:49: DCS failure
(
king.snf.stanford.edu
)
70:
Re: Problem tylannitride 2001-02-06 11:53:49: Fixed by Ray and Mike
(
jgarate.snf.stanford.edu
)
71:
Re: Shutdown tylannitride 2001-02-06 10:16:53: Coated has been done
(
jgarate.snf.stanford.edu
)
72:
Problem tylannitride 2001-02-18 13:03:52: One of the big baffles that are built into the tube (at the front) is broken and is leaning over.
(
mbadi.snf.stanford.edu
)
73:
Shutdown tylannitride 2001-02-20 08:45:57: cooling loader to replace baffle
(
seymour.snf.stanford.edu
)
74:
Re: Problem tylannitride 2001-02-18 13:03:52: One of the big baffles that are built into the tube (at the front) is broken and is leaning over.
(
seymour.snf.stanford.edu
)
75:
Re: Shutdown tylannitride 2001-02-20 08:45:57: baffles replaced system is up
(
seymour.snf.stanford.edu
)
76:
Shutdown tylannitride 2001-02-22 11:55:42: door sensor not working
(
seymour.snf.stanford.edu
)
77:
Re: Shutdown tylannitride 2001-02-22 11:55:42: door sensor working now
(
seymour.snf.stanford.edu
)
78:
Shutdown tylannitride 2001-03-01 07:23:00: Changing NH3 cylinder
(
seymour.snf.stanford.edu
)
79:
Re: Shutdown tylannitride 2001-03-01 07:23:00: NH3 cylinder changed, passed leak check
(
seymour.snf.stanford.edu
)
80:
Shutdown tylannitride 2001-03-05 06:04:16: burnbox clean
(
seymour.snf.stanford.edu
)
81:
Re: Shutdown tylannitride 2001-03-05 06:04:16: burnbox clean coompleted
(
seymour.snf.stanford.edu
)
82:
Shutdown tylannitride 2001-03-10 15:11:57:
(
aaronp.snf.stanford.edu
)
83:
Re: Shutdown tylannitride 2001-03-10 15:11:57: NH3 flows
(
seymour.snf.stanford.edu
)
84:
Shutdown tylannitride 2001-03-15 07:20:54: burnbox temp low
(
seymour.snf.stanford.edu
)
85:
Re: Shutdown tylannitride 2001-03-15 07:20:54: burnbox temp is ok tube is up
(
seymour.snf.stanford.edu
)
86:
Problem tylannitride 2001-03-17 17:40:50: can't run pump10
(
dlaser.snf.stanford.edu
)
87:
Shutdown tylannitride 2001-03-19 07:37:23: pressure sensor not reading
(
seymour.snf.stanford.edu
)
88:
Re: Shutdown tylannitride 2001-03-19 07:37:23: pressure sensor not reading
(
seymour.snf.stanford.edu
)
89:
Re: Problem tylannitride 2001-03-17 17:40:50: pump program is running tube is up
(
seymour.snf.stanford.edu
)
90:
Shutdown tylannitride 2001-04-02 07:11:09: burnbox clean
(
seymour.snf.stanford.edu
)
91:
Comment tylannitride 2001-04-02 08:02:39: Burnbox
(
mdickey.snf.stanford.edu
)
92:
Re: Shutdown tylannitride 2001-04-02 07:11:09: burnbox clean completed
(
mdickey.snf.stanford.edu
)
93:
Problem tylannitride 2001-04-08 12:02:50: tube won't vent
(
dlaser.snf.stanford.edu
)
94:
Shutdown tylannitride 2001-04-09 08:37:45: tube won't vent, loader won't open
(
seymour.snf.stanford.edu
)
95:
Re: Problem tylannitride 2001-04-08 12:02:50: tube won't vent
(
seymour.snf.stanford.edu
)
96:
Re: Shutdown tylannitride 2001-04-09 08:37:45: tube won't vent, loader won't open
(
seymour.snf.stanford.edu
)
97:
Shutdown tylannitride 2001-04-16 07:06:25: burnbox clean
(
seymour.snf.stanford.edu
)
98:
Shutdown tylannitride 2001-04-16 07:08:10:
(
seymour.snf.stanford.edu
)
99:
Re: Shutdown tylannitride 2001-04-16 07:08:10:
(
seymour.snf.stanford.edu
)
[<<-]
[<-]
[->]
[->>]
|