01:
Shutdown tylansige: SiH4 gas cylinder change
(
wheeler.snf.stanford.edu
)
02:
Shutdown Clear tylansige: Cylinder changed
(
wheeler.snf.stanford.edu
)
03:
Shutdown tylansige: pressure in burn box
(
gaul.snf.stanford.edu
)
04:
Shutdown Clear tylansige: completed
(
gaul.snf.stanford.edu
)
05:
Problem tylansige: Display LED's are weak.
(
amol.snf.stanford.edu
)
06:
Problem Clear tylansige: Fixed
(
gaul.snf.stanford.edu
)
07:
Shutdown tylansige:
(
kalavade.snf.stanford.edu
)
08:
Shutdown Clear tylansige: Pump was low on oil.
(
gaul.snf.stanford.edu
)
09:
Shutdown tylansige: Shutdown due to problem
(
amol.snf.stanford.edu
)
10:
Shutdown Clear tylansige: O.K. to run now
(
gaul.snf.stanford.edu
)
11:
Shutdown tylansige: Shutdown for cleaning.
(
gaul.snf.stanford.edu
)
12:
Shutdown Clear tylansige: completed
(
gaul.snf.stanford.edu
)
13:
Problem tylansige: H2 alarm continuously on.
(
amol.snf.stanford.edu
)
14:
Problem Clear tylansige: H2 Alarm
(
seymour.snf.stanford.edu
)
15:
Shutdown tylansige:
(
seymour.snf.stanford.edu
)
16:
Comment tylansige: germaine cylinder change on Friday AM
(
seymour.snf.stanford.edu
)
17:
Shutdown tylansige:
(
seymour.snf.stanford.edu
)
18:
Comment tylansige: Silane cylinder has been changed
(
seymour.snf.stanford.edu
)
19:
Shutdown tylansige 2000-12-18 07:39:35:
(
seymour.snf.stanford.edu
)
20:
Re: Shutdown tylansige 2000-12-18 07:39:35: burnbox clean completed ok to run
(
seymour.snf.stanford.edu
)
21:
Problem tylansige 2001-01-22 12:20:19: in standby state
(
amol.snf.stanford.edu
)
22:
Shutdown tylansige 2001-01-23 07:22:42: system down I/O error
(
seymour.snf.stanford.edu
)
23:
Re: Shutdown tylansige 2001-01-23 07:22:42: system is up
(
seymour.snf.stanford.edu
)
24:
Re: Problem tylansige 2001-01-22 12:20:19: in standby state
(
seymour.snf.stanford.edu
)
25:
Comment tylansige 2001-02-02 09:28:45: Silane cylinder change on Monday Feb 5
(
seymour.snf.stanford.edu
)
26:
Shutdown tylansige 2001-02-05 06:14:24:
(
seymour.snf.stanford.edu
)
27:
Re: Shutdown tylansige 2001-02-05 06:14:24: Silane cylinder changed
(
seymour.snf.stanford.edu
)
28:
Shutdown tylansige 2001-02-08 20:12:01: tube is cold!
(
amol.snf.stanford.edu
)
29:
Re: Shutdown tylansige 2001-02-08 20:12:01: system is up
(
seymour.snf.stanford.edu
)
30:
Shutdown tylansige 2001-02-12 19:07:46: Silane flow stopped
(
amol.snf.stanford.edu
)
31:
Re: Shutdown tylansige 2001-02-12 19:07:46: Silane flow stopped
(
seymour.snf.stanford.edu
)
32:
Shutdown tylansige 2001-02-14 07:50:01: silane mfc faults
(
seymour.snf.stanford.edu
)
33:
Re: Shutdown tylansige 2001-02-14 07:50:01: Silane MFC has been replaced
(
seymour.snf.stanford.edu
)
34:
Shutdown tylansige 2001-03-05 06:04:47: burnbox clean
(
seymour.snf.stanford.edu
)
35:
Re: Shutdown tylansige 2001-03-05 06:04:47: burnbox clean completed
(
seymour.snf.stanford.edu
)
36:
Shutdown tylansige 2001-03-15 07:21:27: burnbox temp low
(
seymour.snf.stanford.edu
)
37:
Re: Shutdown tylansige 2001-03-15 07:21:27: burnbox temp is ok tube is up
(
seymour.snf.stanford.edu
)
38:
Shutdown tylansige 2001-04-02 07:12:01: burnbox clean
(
seymour.snf.stanford.edu
)
39:
Comment tylansige 2001-04-02 08:03:13: Burnbox
(
mdickey.snf.stanford.edu
)
40:
Re: Shutdown tylansige 2001-04-02 07:12:01: burnbox clean completed
(
mdickey.snf.stanford.edu
)
41:
Shutdown tylansige 2001-04-09 08:38:29: aborts in step 70
(
seymour.snf.stanford.edu
)
42:
Re: Shutdown tylansige 2001-04-09 08:38:29: aborts in step 70
(
seymour.snf.stanford.edu
)
43:
Shutdown tylansige 2001-04-16 07:07:08: burnbox clean
(
seymour.snf.stanford.edu
)
44:
Re: Shutdown tylansige 2001-04-16 07:07:08: burnbox clean
(
seymour.snf.stanford.edu
)
45:
Shutdown tylansige 2001-04-17 10:17:42: I/O error
(
seymour.snf.stanford.edu
)
46:
Re: Shutdown tylansige 2001-04-17 10:17:42: I/O error
(
seymour.snf.stanford.edu
)
47:
Shutdown tylansige 2001-05-23 07:20:15: silane cylinder change
(
seymour.snf.stanford.edu
)
48:
Comment tylansige 2001-05-23 09:02:20: the silane cylinder is on leak test
(
seymour.snf.stanford.edu
)
49:
Re: Shutdown tylansige 2001-05-23 07:20:15: silane cylinder change
(
seymour.snf.stanford.edu
)
50:
Shutdown tylansige 2001-05-24 17:27:02: SIGEPUMP aborts by itself.
(
amol.snf.stanford.edu
)
51:
Re: Shutdown tylansige 2001-05-24 17:27:02: SIGEPUMP aborts by itself.
(
seymour.snf.stanford.edu
)
52:
Shutdown tylansige 2001-05-27 16:59:57: I/O error. Furnace in unknown state
(
amol.snf.stanford.edu
)
53:
Re: Shutdown tylansige 2001-05-27 16:59:57: I/O error. Furnace in unknown state
(
seymour.snf.stanford.edu
)
54:
Shutdown tylansige 2001-06-01 15:18:36: burnbox down
(
seymour.snf.stanford.edu
)
55:
Re: Shutdown tylansige 2001-06-01 15:18:36: burnbox down
(
seymour.snf.stanford.edu
)
56:
Shutdown tylansige 2001-06-04 16:34:33: Heaters not working
(
amol.snf.stanford.edu
)
57:
Re: Shutdown tylansige 2001-06-04 16:34:33: Heaters not working
(
seymour.snf.stanford.edu
)
58:
Problem tylansige 2001-06-06 19:14:47: GeH4 flow reading was zero.
(
chion.snf.stanford.edu
)
59:
Re: Problem tylansige 2001-06-06 19:14:47: GeH4 flow reading was zero.
(
seymour.snf.stanford.edu
)
60:
Problem tylansige 2001-06-12 19:17:25: Thermocouple Problem-
(
kalavade.snf.stanford.edu
)
61:
Re: Problem tylansige 2001-06-12 19:17:25: Thermocouple Problem-
(
seymour.snf.stanford.edu
)
62:
Problem tylansige 2001-06-20 16:40:37: N2 backflow control not working!
(
chion.snf.stanford.edu
)
63:
Problem tylansige 2001-06-21 17:05:21: tcu error
(
rohits.snf.stanford.edu
)
64:
Shutdown tylansige 2001-06-21 18:38:45: Pumpdown fails, also TCU IO error
(
rohits.snf.stanford.edu
)
65:
Problem tylansige 2001-06-25 13:37:26: vacuum leak in tube
(
seymour.snf.stanford.edu
)
66:
Re: Shutdown tylansige 2001-06-21 18:38:45: Pumpdown fails, also TCU IO error
(
seymour.snf.stanford.edu
)
67:
Re: Problem tylansige 2001-06-25 13:37:26: vacuum leak in tube
(
seymour.snf.stanford.edu
)
68:
Re: Problem tylansige 2001-06-21 17:05:21: tcu error
(
seymour.snf.stanford.edu
)
69:
Re: Problem tylansige 2001-06-20 16:40:37: N2 backflow control not working!
(
seymour.snf.stanford.edu
)
70:
Shutdown tylansige 2001-07-11 07:11:59: Silane MFC causing alarms needs calibration
(
seymour.snf.stanford.edu
)
71:
Shutdown tylansige 2001-07-16 06:23:55: burnbox clean
(
seymour.snf.stanford.edu
)
72:
Re: Shutdown tylansige 2001-07-16 06:23:55: burnbox clean
(
seymour.snf.stanford.edu
)
73:
Comment tylansige 2001-07-16 08:14:56: MKS Pressure sensor out for Cailbration
(
seymour.snf.stanford.edu
)
74:
Re: Shutdown tylansige 2001-07-11 07:11:59: Silane MFC causing alarms needs calibration
(
seymour.snf.stanford.edu
)
75:
Shutdown tylansige 2001-07-30 07:15:01: down for burnbox clean
(
seymour.snf.stanford.edu
)
76:
Re: Shutdown tylansige 2001-07-30 07:15:01: down for burnbox clean
(
seymour.snf.stanford.edu
)
77:
Shutdown tylansige 2001-08-05 20:59:44: Calibration of SiH4 MFC
(
mcvittie.snf.stanford.edu
)
78:
Re: Shutdown tylansige 2001-08-05 20:59:44: Calibration of SiH4 MFC
(
seymour.snf.stanford.edu
)
79:
Problem tylansige 2001-08-17 19:23:54: Wand contamination
(
chion.snf.stanford.edu
)
80:
Re: Problem tylansige 2001-08-17 19:23:54: Wand contamination
(
mcvittie.snf.stanford.edu
)
81:
Shutdown tylansige 2001-08-20 21:09:13: power failure
(
rohits.snf.stanford.edu
)
82:
Re: Shutdown tylansige 2001-08-20 21:09:13: power failure
(
seymour.snf.stanford.edu
)
83:
Shutdown tylansige 2001-09-20 16:18:33: germaine cylinder change in process
(
seymour.snf.stanford.edu
)
84:
Re: Shutdown tylansige 2001-09-20 16:18:33: germaine cylinder change in process
(
mdickey.snf.stanford.edu
)
85:
Shutdown tylansige 2001-09-21 18:30:06: leak in the tube
(
sjain.snf.stanford.edu
)
86:
Re: Shutdown tylansige 2001-09-21 18:30:06: leak in the tube
(
seymour.snf.stanford.edu
)
87:
Problem tylansige 2002-05-10 10:19:55: needsa coat and characterization
(
seymour.snf.stanford.edu
)
88:
Shutdown tylansige 2002-05-21 17:12:27: Failed leak check 2x
(
gladys.snf.stanford.edu
)
89:
Re: Shutdown tylansige 2002-05-21 17:12:27: Failed leak check 2x
(
seymour.snf.stanford.edu
)
90:
Re: Problem tylansige 2002-05-10 10:19:55: needsa coat and characterization
(
seymour.snf.stanford.edu
)
91:
Shutdown tylansige 2002-06-10 06:46:16: SiH4 Cylinder Chajnge
(
tberg.snf.stanford.edu
)
92:
Re: Shutdown tylansige 2002-06-10 06:46:16: SiH4 Cylinder Chajnge
(
tberg.snf.stanford.edu
)
93:
Shutdown tylansige 2002-07-05 10:07:18: running the backup t/c calibration routine
(
seymour.snf.stanford.edu
)
94:
Re: Shutdown tylansige 2002-07-05 10:07:18: running the backup t/c calibration routine
(
seymour.snf.stanford.edu
)
95:
Shutdown tylansige 2002-08-05 06:39:43: changing SiH4
(
seymour.snf.stanford.edu
)
96:
Re: Shutdown tylansige 2002-08-05 06:39:43: changing SiH4
(
seymour.snf.stanford.edu
)
97:
Problem tylansige 2002-08-06 07:58:37: waiting for test result
(
gladys.snf.stanford.edu
)
98:
Shutdown tylansige 2002-09-20 07:03:37: cleaning burnbox
(
seymour.snf.stanford.edu
)
99:
Re: Shutdown tylansige 2002-09-20 07:03:37: cleaning burnbox
(
seymour.snf.stanford.edu
)
[<<-]
[<-]
[->]
[->>]
|