Messages 0xx


01: Problem wbmetal: ((none))
02: Shutdown wbmetal: wbmetal ((none))
03: Shutdown Clear wbmetal: clearing shutdown report ((none))
04: Problem Clear wbmetal: changed bad solenoid for door seal. (cbaxter.snf.stanford.edu)
05: Problem Clear wbmetal: (cbaxter.snf.stanford.edu)
06: Problem wbmetal: RHS Dump Rinser does not work (doesn't even fill with water...dump door stuck open?) (mbartsch.snf.stanford.edu)
07: Problem Clear wbmetal: reseated connector on qdr controller poor contact. (cbaxter.snf.stanford.edu)
08: Problem wbmetal: std-by H2O flow to hi on dump Lt dump rinse (mcvittie.snf.stanford.edu)
09: Problem wbmetal: dump rinser (heureux.snf.stanford.edu)
10: Problem Clear wbmetal: repair air leak for high level sensor (cbaxter.snf.stanford.edu)
11: Problem Clear wbmetal: repair air leak and cycle QDR (cbaxter.snf.stanford.edu)
12: Problem wbmetal: dump rinsers (tui3.snf.stanford.edu)
13: Problem wbmetal: Neither dump rinser works (hansen.snf.stanford.edu)
14: Problem wbmetal: Fixed Dump Rinsers-Loose wires. Jim (mcvittie.snf.stanford.edu)
15: Problem Clear wbmetal: (booth.snf.stanford.edu)
16: Problem Clear wbmetal: (booth.snf.stanford.edu)
17: Problem Clear wbmetal: (booth.snf.stanford.edu)
18: Problem wbmetal: wbmetal srd (pcastle.snf.stanford.edu)
19: Problem Clear wbmetal: changed fuse on controller (cbaxter.snf.stanford.edu)
20: Problem wbmetal: right dumprinser problematic (rtchang.snf.stanford.edu)
21: Problem Clear wbmetal: lower air supply for bath filled.. (cbaxter.snf.stanford.edu)
22: Problem wbmetal: lf hand dump rinser not cycling correctly (latta.snf.stanford.edu)
23: Re: Problem wbmetal 2000-12-05 11:20:58: lf hand dump rinser not cycling correctly (cbaxter.snf.stanford.edu)
24: Problem wbmetal 2001-01-30 12:50:56: HF dripped all over deck (king.snf.stanford.edu)
25: Re: Problem wbmetal 2001-01-30 12:50:56: HF dripped all over deck (seymour.snf.stanford.edu)
26: Comment wbmetal 2001-02-14 11:03:59: bath temp (kcheng.snf.stanford.edu)
27: Problem wbmetal 2001-03-15 20:02:10: prs 1000 (pcastle.snf.stanford.edu)
28: Problem wbmetal 2001-03-22 13:38:07: left dump rinser level is too low to rinse (pruitt.snf.stanford.edu)
29: Problem wbmetal 2001-03-30 10:50:59: Lt hand rinser in full flow in STOP mode (latta.snf.stanford.edu)
30: Re: Problem wbmetal 2001-03-30 10:50:59: Lt hand rinser working (jhaydon.snf.stanford.edu)
31: Re: Problem wbmetal 2001-03-22 13:38:07: left dump rinser level is too low to rinse (jhaydon.snf.stanford.edu)
32: Problem wbmetal 2001-04-13 21:10:49: Left Dump Rinser Control not functioning (narya.snf.stanford.edu)
33: Problem wbmetal 2001-04-13 21:20:09: N2 blow gun has low pressure (hopcroft.snf.stanford.edu)
34: Re: Problem wbmetal 2001-04-13 21:20:09: N2 blow gun has low pressure (jhaydon.snf.stanford.edu)
35: Re: Problem wbmetal 2001-04-13 21:10:49: Left Dump Rinser Control not functioning (jhaydon.snf.stanford.edu)
36: Shutdown wbmetal 2001-04-30 08:11:46: sensor change and drain temp change (seymour.snf.stanford.edu)
37: Re: Shutdown wbmetal 2001-04-30 08:11:46: sensor change and drain temp change (seymour.snf.stanford.edu)
38: Problem wbmetal 2001-05-02 14:24:23: PRS1000 pot level indicator (pbrink.snf.stanford.edu)
39: Comment wbmetal 2001-05-25 16:21:49: red contaminatiojn (evelyn.snf.stanford.edu)
40: Re: Problem wbmetal 2001-05-02 14:24:23: PRS1000 pot level indicator (jhaydon.snf.stanford.edu)
41: Problem wbmetal 2001-06-05 13:43:21: (indrani.snf.stanford.edu)
42: Re: Problem wbmetal 2001-06-05 13:43:21: Dump rinser (uli.snf.stanford.edu)
43: Problem wbmetal 2001-06-29 10:38:15: DI jets in left dump rinser running constantly (greene.snf.stanford.edu)
44: Re: Problem wbmetal 2001-06-29 10:38:15: DI jets in left dump rinser running constantly (jhaydon.snf.stanford.edu)
45: Problem wbmetal 2001-07-09 11:08:42: Magnehelic reads 0.25; DI fill not working (hansen.snf.stanford.edu)
46: Problem wbmetal 2001-07-10 16:02:23: (beckwith.snf.stanford.edu)
47: Re: Problem wbmetal 2001-07-10 16:02:23: (jhaydon.snf.stanford.edu)
48: Problem wbmetal 2001-07-16 12:38:30: DI fill dump rinser not working (greene.snf.stanford.edu)
49: Re: Problem wbmetal 2001-07-16 12:38:30: DI fill dump rinser not working (jhaydon.snf.stanford.edu)
50: Re: Problem wbmetal 2001-07-09 11:08:42: Magnehelic reads 0.25; DI fill not working (jhaydon.snf.stanford.edu)
51: Problem wbmetal 2001-07-23 19:59:59: spin dryer not spinning (nlui.snf.stanford.edu)
52: Re: Problem wbmetal 2001-07-23 19:59:59: spin dryer not spinning (jhaydon.snf.stanford.edu)
53: Problem wbmetal 2001-08-20 12:02:15: wbmetal: 20:1BOE bath won't drain. Gladys (gladys.snf.stanford.edu)
54: Shutdown wbmetal 2001-08-25 07:52:17: facility (rcrane.snf.stanford.edu)
55: Re: Shutdown wbmetal 2001-08-25 07:52:17: facility (rcrane.snf.stanford.edu)
56: Re: Problem wbmetal 2001-08-20 12:02:15: wbmetal: 20:1BOE bath won't drain. Gladys (jhaydon.snf.stanford.edu)
57: Problem wbmetal 2001-09-13 16:27:44: SRD sometimes doesn't spin (beckwith.snf.stanford.edu)
58: Re: Problem wbmetal 2001-09-13 16:27:44: SRD sometimes doesn't spin (booth.snf.stanford.edu)
59: Problem wbmetal 2001-12-11 12:32:14: many broken wafers in the bottom of the Al etch bath (beckwith.snf.stanford.edu)
60: Problem wbmetal 2002-01-15 11:27:11: door to SRD is leaking (beckwith.snf.stanford.edu)
61: Re: Problem wbmetal 2002-01-15 11:27:11: door to SRD is leaking (cbaxter.snf.stanford.edu)
62: Re: Problem wbmetal 2001-12-11 12:32:14: many broken wafers in the bottom of the Al etch bath (jhaydon.snf.stanford.edu)
63: Shutdown wbmetal 2002-07-02 06:28:10: scrubbber work (tberg.snf.stanford.edu)
64: Re: Shutdown wbmetal 2002-07-02 06:28:10: scrubbber work (seymour.snf.stanford.edu)
65: Shutdown wbmetal 2002-07-03 06:28:27: scrubber work (tberg.snf.stanford.edu)
66: Re: Shutdown wbmetal 2002-07-03 06:28:27: scrubber work (jhaydon.snf.stanford.edu)
67: Shutdown wbmetal 2002-08-06 07:46:50: fan bearing needs replacement (gladys.snf.stanford.edu)
68: Re: Shutdown wbmetal 2002-08-06 07:46:50: fan bearing needs replacement (latta.snf.stanford.edu)
69: Problem wbmetal 2002-12-12 12:09:35: right dump rinser does not work...no water! (beckwith.snf.stanford.edu)
70: Re: Problem wbmetal 2002-12-12 12:09:35: right dump rinser does not work...no water! (jhaydon.snf.stanford.edu)
71: Problem wbmetal 2003-01-26 12:39:43: broken wafer in spin dryer (mwolfson.snf.stanford.edu)
72: Re: Problem wbmetal 2003-01-26 12:39:43: broken wafer in spin dryer (jhaydon.snf.stanford.edu)
75: Shutdown wbmetal 2003-03-20 14:29:49: Report Shutdown for wbmetal (evelyn.snf.stanford.edu)
76: Re: Shutdown wbmetal 2003-03-20 14:29:49: Mistake (hphan.snf.stanford.edu)
77: Problem wbmetal 2003-06-02 10:04:15: Report Problem for wbmetal (sanli.snf.stanford.edu)
78: Problem wbmetal 2003-07-03 21:16:10: LH dump rinser level sense- wbmetal (ericp.snf.stanford.edu)
79: Re: Problem wbmetal 2003-07-03 21:16:10: Report Clear for wbmetal (jhaydon.snf.stanford.edu)
80: Problem wbmetal 2003-07-25 16:05:47: LDR not working (chion.snf.stanford.edu)
81: Re: Problem wbmetal 2003-07-25 16:05:47: Report Clear for wbmetal (jhaydon.snf.stanford.edu)
82: Shutdown wbmetal 2003-08-22 13:18:07: Report Shutdown for wbmetal (harshal.snf.stanford.edu)
83: Re: Shutdown wbmetal 2003-08-22 13:18:07: Report Clear for wbmetal (latta.snf.stanford.edu)
84: Problem wbmetal 2003-09-02 14:44:33: Report Problem for wbmetal (emes.snf.stanford.edu)
85: Problem wbmetal 2003-09-02 14:55:53: Report Problem for wbmetal (emes.snf.stanford.edu)
86: Re: Problem wbmetal 2003-09-02 14:44:33: Report Clear for wbmetal (jhaydon.snf.stanford.edu)
87: Re: Problem wbmetal 2003-09-02 14:55:53: Report Clear for wbmetal (jhaydon.snf.stanford.edu)
88: Problem wbmetal 2003-09-13 17:51:42: Report Problem for wbmetal (ychliu.snf.stanford.edu)
89: Re: Problem wbmetal 2003-09-13 17:51:42: Report Clear for wbmetal (jhaydon.snf.stanford.edu)
90: Problem wbmetal 2003-09-30 09:38:40: Report Problem for wbmetal (bwacker.snf.stanford.edu)
91: Re: Problem wbmetal 2003-09-30 09:38:40: Report Clear for wbmetal (jhaydon.snf.stanford.edu)
92: Problem wbmetal 2003-12-01 23:09:02: Report Problem for wbmetal (quickwin.snf.stanford.edu)
93: Re: Problem wbmetal 2003-12-01 23:09:02: Report Problem for wbmetal (jhaydon.snf.stanford.edu)
94: Problem wbmetal 2003-12-11 12:04:37: Left dump-rinse (tomada.snf.stanford.edu)
95: Re: Problem wbmetal 2003-12-11 12:04:37: Left dump-rinse (jhaydon.snf.stanford.edu)
96: Problem wbmetal 2004-04-01 14:59:25: L dump rinser sprays, but does not fill up with (beckwith.snf.stanford.edu)
97: Comment wbmetal 2004-04-01 15:01:11: oops! I meant wbnonmetal, not wbmetal. (beckwith.snf.stanford.edu)
98: Re: Problem wbmetal 2004-04-01 14:59:25: L dump rinser sprays, but does not fill up with (jhaydon.snf.stanford.edu)
99: Re: Comment wbmetal 2004-04-01 15:01:11: oops! I meant wbnonmetal, not wbmetal. (jhaydon.snf.stanford.edu)