Messages 2xx


00: Shutdown wbsilicide SNF 2007-10-26 08:16:35: down for work on scrubber (jhaydon.snf.stanford.edu)
01: Re: Shutdown wbsilicide SNF 2007-10-26 08:16:35: down for work on scrubber (jhaydon.snf.stanford.edu)
02: Problem wbsilicide SNF 2007-11-20 09:23:32: Cleanwipe in HCl Bath (jrjain.snf.stanford.edu)
03: Re: Problem wbsilicide SNF 2007-11-20 09:23:32: Cleanwipe in HCl Bath (uli.snf.stanford.edu)
04: Problem wbsilicide SNF 2008-01-03 09:12:35: Faulty thermometer in left side hot pot (mtang.snf.stanford.edu)
05: Comment wbsilicide SNF 2008-02-14 08:13:25: testing left hotpot do not use (jhaydon.snf.stanford.edu)
06: Re: Problem wbsilicide SNF 2008-01-03 09:12:35: Faulty thermometer in left side hot pot (jhaydon.snf.stanford.edu)
07: Problem wbsilicide SNF 2008-02-19 08:21:27: spin dryer doesn't seem to work (shwong.snf.stanford.edu)
08: Shutdown wbsilicide SNF 2008-02-22 10:13:49: no DI water (maurice.snf.stanford.edu)
09: Re: Shutdown wbsilicide SNF 2008-02-22 10:13:49: no DI water (mtang.snf.stanford.edu)
10: Problem wbsilicide SNF 2008-02-23 21:54:42: wbsilicide being decontaminated (mtang.snf.stanford.edu)
11: Problem wbsilicide SNF 2008-02-24 09:15:54: Leak under wbsilicide .... FuseSeal, I think (shott.snf.stanford.edu)
12: Problem wbsilicide SNF 2008-02-24 11:12:40: please remove sign on SRD (gth.snf.stanford.edu)
13: Re: Problem wbsilicide SNF 2008-02-23 21:54:42: wbsilicide being decontaminated (uli.snf.stanford.edu)
14: Re: Problem wbsilicide SNF 2008-02-24 11:12:40: please remove sign on SRD (jhaydon.snf.stanford.edu)
15: Re: Comment wbsilicide SNF 2008-02-14 08:13:25: testing left hotpot do not use (uli.snf.stanford.edu)
16: Re: Problem wbsilicide SNF 2008-02-19 08:21:27: spin dryer doesn't seem to work (uli.snf.stanford.edu)
17: Re: Problem wbsilicide SNF 2008-02-24 09:15:54: Leak under wbsilicide .... FuseSeal, I think (uli.snf.stanford.edu)
18: Problem wbsilicide SNF 2008-03-01 18:51:26: Erroneous "low liquid" alarm (ahryciw.snf.stanford.edu)
19: Re: Problem wbsilicide SNF 2008-03-01 18:51:26: Erroneous "low liquid" alarm (jhaydon.snf.stanford.edu)
20: Comment wbsilicide SNF 2008-03-20 14:30:53: Left pot and dump rinse now "gold-contaminated" (mtang.snf.stanford.edu)
21: Problem wbsilicide SNF 2008-03-25 16:58:10: 4:1 sulfuric pot not draining (maurice.snf.stanford.edu)
22: Re: Problem wbsilicide SNF 2008-03-25 16:58:10: 4:1 sulfuric pot not draining (jhaydon.snf.stanford.edu)
23: Shutdown wbsilicide SNF 2008-04-11 11:04:13: N2 leak (maurice.snf.stanford.edu)
24: Re: Shutdown wbsilicide SNF 2008-04-11 11:04:13: N2 leak (jhaydon.snf.stanford.edu)
25: Problem wbsilicide SNF 2008-04-26 15:00:56: wafer lost drainage did not work (buchimax.snf.stanford.edu)
26: Re: Problem wbsilicide SNF 2008-04-26 15:00:56: wafer lost drainage did not work (John Shott)
27: Re: Problem wbsilicide SNF 2008-04-26 15:00:56: wafer lost drainage did not work (shott.snf.stanford.edu)
28: Problem wbsilicide SNF 2008-05-04 13:16:42: 4:1 piranha pot does not drain ! (riteshj.snf.stanford.edu)
29: Re: Problem wbsilicide SNF 2008-05-04 13:16:42: 4:1 piranha pot does not drain ! (shott.snf.stanford.edu)
30: Shutdown wbsilicide SNF 2008-05-09 09:22:11: contamination of center hot pot (jhaydon.snf.stanford.edu)
31: Re: Shutdown wbsilicide SNF 2008-05-09 09:22:11: contamination of center hot pot (uli.snf.stanford.edu)
32: Comment wbsilicide SNF 2008-05-16 19:11:22: gold contaminated handle (rwoo.snf.stanford.edu)
33: Comment wbsilicide SNF 2008-06-05 14:50:04: silicide box and cassette decon'ed (maurice.snf.stanford.edu)
34: Problem wbsilicide SNF 2008-07-03 10:39:00: Spin dryer not turning on (maurice.snf.stanford.edu)
35: Re: Problem wbsilicide SNF 2008-07-03 10:39:00: Spin dryer not turning on (maurice.snf.stanford.edu)
36: Re: Comment wbsilicide SNF 2008-06-05 14:50:04: silicide box and cassette decon'ed (maurice.snf.stanford.edu)
37: Problem wbsilicide SNF 2008-07-21 00:54:40: silicide hotpot not draining (equipment was enabled) (rshyam.snf.stanford.edu)
38: Re: Problem wbsilicide SNF 2008-07-21 00:54:40: silicide hotpot not draining (equipment was enabled) (jhaydon.snf.stanford.edu)
39: Problem wbsilicide SNF 2008-07-21 21:35:44: Only one 4" handle for silicide use (king.snf.stanford.edu)
40: Comment wbsilicide SNF 2008-07-29 15:35:16: silicide bench will be down (jhaydon.snf.stanford.edu)
41: Re: Comment wbsilicide SNF 2008-07-29 15:35:16: silicide bench will be down (jhaydon.snf.stanford.edu)
42: Comment wbsilicide SNF 2008-07-31 16:44:24: Bench de-con'ed (latta.snf.stanford.edu)
43: Re: Comment wbsilicide SNF 2008-05-16 19:11:22: gold contaminated handle (latta.snf.stanford.edu)
44: Re: Problem wbsilicide SNF 2008-07-21 21:35:44: Only one 4" handle for silicide use (jhaydon.snf.stanford.edu)
45: Problem wbsilicide SNF 2008-08-12 19:57:07: spin dryer has been down for ages (rshyam.snf.stanford.edu)
46: Re: Problem wbsilicide SNF 2008-08-12 19:57:07: spin dryer has been down for ages (jhaydon.snf.stanford.edu)
47: Problem wbsilicide SNF 2008-09-16 12:32:42: spin drying doesn't work well (huimei.snf.stanford.edu)
48: Re: Problem wbsilicide SNF 2008-09-16 12:32:42: spin drying doesn't work well (jhaydon.snf.stanford.edu)
49: Problem wbsilicide SNF 2008-09-22 13:08:53: spin dryer rotates intermittently (rshyam.snf.stanford.edu)
50: Shutdown wbsilicide SNF 2008-09-24 07:49:19: DI Water upgrade (mtang.snf.stanford.edu)
51: Re: Shutdown wbsilicide SNF 2008-09-24 07:49:19: DI Water upgrade (mtang.snf.stanford.edu)
52: Re: Problem wbsilicide SNF 2008-09-22 13:08:53: spin dryer rotates intermittently (latta.snf.stanford.edu)
53: Re: Comment wbsilicide SNF 2008-07-31 16:44:24: Bench de-con'ed (latta.snf.stanford.edu)
54: Comment wbsilicide SNF 2008-11-16 04:55:45: 4-inch handle (rshyam.snf.stanford.edu)
55: Re: Comment wbsilicide SNF 2008-11-16 04:55:45: 4-inch handle (uli.snf.stanford.edu)
56: Comment wbsilicide SNF 2009-02-19 11:50:11: WBsilicide Gold Sulf-Perox seems slow to heat (jimkruger.snf.stanford.edu)
57: Problem wbsilicide SNF 2009-02-21 14:37:32: 5:1:1 bath controller won't stop alarming (grahamab.snf.stanford.edu)
58: Re: Problem wbsilicide SNF 2009-02-21 14:37:32: 5:1:1 bath controller won't stop alarming (jhaydon.snf.stanford.edu)
59: Comment wbsilicide SNF 2009-03-30 09:53:41: only one 4" handle (grahamab.snf.stanford.edu)
60: Problem wbsilicide SNF 2009-03-30 11:23:01: nitrogen gun barely works (grahamab.snf.stanford.edu)
61: Re: Problem wbsilicide SNF 2009-03-30 11:23:01: nitrogen gun barely works (jhaydon.snf.stanford.edu)
62: Comment wbsilicide SNF 2009-05-13 18:59:36: Gold-contaminated cassette is missing (alshehaj.snf.stanford.edu)
63: Re: Comment wbsilicide SNF 2009-05-13 18:59:36: Gold-contaminated cassette is missing (uli.snf.stanford.edu)
64: Problem wbsilicide SNF 2009-06-11 16:09:08: right dumprinser not working (uli.snf.stanford.edu)
65: Re: Problem wbsilicide SNF 2009-06-11 16:09:08: right dumprinser not working (jhaydon.snf.stanford.edu)
66: Comment wbsilicide SNF 2009-06-29 16:03:36: cassette with wafers left in gold bath! Why? (uli.snf.stanford.edu)
67: Comment wbsilicide SNF 2009-07-10 09:24:06: air leaking by SRD when enabled (gyama.snf.stanford.edu)
68: Re: Comment wbsilicide SNF 2009-06-29 16:03:36: cassette with wafers left in gold bath! Why? (uli.snf.stanford.edu)
69: Problem wbsilicide SNF 2009-08-06 19:58:00: missing 4" gold contaminated casette (dasgupta.snf.stanford.edu)
70: Re: Problem wbsilicide SNF 2009-08-06 19:58:00: missing 4" gold contaminated casette (uli.snf.stanford.edu)
71: Comment wbsilicide SNF 2009-08-09 17:39:35: found dirty casette (filip.snf.stanford.edu)
72: Comment wbsilicide SNF 2009-08-10 10:32:58: reminder (ehe.snf.stanford.edu)
73: Problem wbsilicide SNF 2009-09-10 02:42:51: casette still dirty (filip.snf.stanford.edu)
74: Problem wbsilicide SNF 2009-09-17 16:53:32: Do not use Spin rinse dryer! (mtang.snf.stanford.edu)
75: Re: Comment wbsilicide SNF 2009-08-09 17:39:35: found dirty casette (latta.snf.stanford.edu)
76: Re: Comment wbsilicide SNF 2009-08-10 10:32:58: reminder (latta.snf.stanford.edu)
77: Re: Problem wbsilicide SNF 2009-09-10 02:42:51: casette still dirty (uli.snf.stanford.edu)
78: Re: Problem wbsilicide SNF 2009-09-17 16:53:32: Do not use Spin rinse dryer! (uli.snf.stanford.edu)
79: Comment wbsilicide SNF 2010-04-05 13:47:36: found casette in dump rinse (ehe.snf.stanford.edu)
80: Re: Comment wbsilicide SNF 2010-04-05 13:47:36: found casette in dump rinse (uli.snf.stanford.edu)
81: Comment wbsilicide SNF 2010-04-23 11:12:30: Silicide cassette found in Gold dump rinser (maurice.snf.stanford.edu)
82: Comment wbsilicide SNF 2010-04-23 11:13:45: Dried blue residue on bench top (maurice.snf.stanford.edu)
83: Problem wbsilicide SNF 2010-05-17 23:58:22: left Gold tank doesn't drain (liangjl.snf.stanford.edu)
84: Problem wbsilicide SNF 2010-06-16 18:14:34: left dump rinser not fully functional. (uli.snf.stanford.edu)
85: Re: Problem wbsilicide SNF 2010-06-16 18:14:34: left dump rinser not fully functional. (jhaydon.snf.stanford.edu)
86: Comment wbsilicide SNF 2010-06-24 06:55:41: resist flakes in left hot bath (dkozak.snf.stanford.edu)
87: Re: Comment wbsilicide SNF 2010-06-24 06:55:41: resist flakes in left hot bath (uli.snf.stanford.edu)
88: Problem wbsilicide SNF 2010-06-30 08:54:14: gold pot at 63C not draining (fungus.snf.stanford.edu)
89: Re: Problem wbsilicide SNF 2010-05-17 23:58:22: left Gold tank doesn't drain (latta.snf.stanford.edu)
90: Comment wbsilicide SNF 2010-08-06 13:26:16: Drain Temp on gold hot pot is 50C (latta.snf.stanford.edu)
91: Re: Problem wbsilicide SNF 2010-06-30 08:54:14: gold pot at 63C not draining (latta.snf.stanford.edu)
92: Problem wbsilicide SNF 2010-08-30 17:39:17: 2nd casette missing (filip.snf.stanford.edu)
93: Re: Problem wbsilicide SNF 2010-08-30 17:39:17: 2nd casette missing (uli.snf.stanford.edu)
94: Problem wbsilicide SNF 2010-10-08 19:12:19: wafer broke (merwan.snf.stanford.edu)
95: Re: Problem wbsilicide SNF 2010-10-08 19:12:19: wafer broke (uli.snf.stanford.edu)
96: Problem wbsilicide SNF 2010-10-26 15:00:16: Floating material (karthikv.snf.stanford.edu)
97: Problem wbsilicide SNF 2010-10-31 13:13:26: spin dryer did not spin (cfchiang.snf.stanford.edu)
98: Comment wbsilicide SNF 2010-10-31 13:53:55: spin dryer ok (cfchiang.snf.stanford.edu)
99: Re: Problem wbsilicide SNF 2010-10-31 13:13:26: spin dryer did not spin (jhaydon.snf.stanford.edu)