For experienced users only, per email below. Enjoy. mike Quoting James Conway <jwc@snf.stanford.edu>: > Greetings RAITH Community: > > The system is coming back up after repairs. More testing and > mechanical adjustments to the sample holders are required and I will > continue this effort tomorrow. > Experienced Users only unless you have my permission through tomorrow > afternoon. Call me if you have any concerns. > Users on the CORAL schedule overnight this evening and morning have my > blessings to come onto the system. > Good Luck. Please report if you see anything unusual. > > Thank you, > > James Conway > > > -------- Original Message -------- > Subject: Problem raith SNF 2008-04-23 19:15:49: calibration are > required to piezo post and mech. adjustments to all sample holders need > to be completed > Date: Wed, 23 Apr 2008 19:15:49 -0700 > From: jwc@snf.stanford.edu > To: raith-pcs@snf.stanford.edu > > > > Greetings: > Thanks to an incredible effort and response by RAITH Field service > leader Bern Steggemann, whom by chance was traveling through SFO this > morning we have effected repairs and replacement to the ceramic ball > mounted on Piezo post three of the XY Laser stage. > The electrical connection to the Faraday Cup on stage also resolved > itself with this repair. > > I have tested the Load Lock and Robot arm and exchange position > settings for sample holder transfer. > Just brought the FE-GUN back up and it will take about six hours for > emission to stabilize and possibly a day or more to return to previous > emission levels. Vacuum levels are elevated but safe to resume > operations this evening. > > I loaded the Universal Sample holder and attempted to level using the > Piezo controls, but was unable to successfully level to any less than a > total delta WD of 0.194 mm across a 96 mm axis across a 100 mm wafer. > Note Piezo three is the fixed reference post height that the others are > adjusted to mechanically. > I desire to repeat this measurement again before attempting to perform > mechanical adjustments to both the Universal and Electrostatic chuck > sample holders. > Note the Std. sample holder cannot be adjusted as they are pressed in, > its detents are worn, and likely should soon be replaced or simply > discarded. I will confirm with RAITH USA Inc. if I need to recalibrate > the piezo controls before performing mechanical adjustments. > > *With some reservations I am releasing the system to experienced users > only.* Users should carefully check their focus and perform a write > field alignment within ~ 5 mm of where they intend to write their > patterns. Be sure TO center all piezos as you come onto the system. > Thank you for your support! > James Conway