Greetings Ebeam Lab Users:

The proposed date for the next Ebeam Town Meeting 
<http://snf.stanford.edu/cgi-bin/ezmlm-cgi?2160:mss:1029:200412:caddckfgapglokjgmefl>

is Friday January 21, 2004 2 -4 PM in CIS 101

The Agenda remains open for your suggestions and additions:

Agenda Items:

Raith Scheduling on Coral; managing a limited resource. 20 minutes
    Seeking your contributions and opinions on our current usage 
policies and discussion and proposals of modifications to these policies.

Discussions on methods users can implement to increase sample throughput 
on the system. 10 minutes

Recent PCM testing results in brief. - 5 minutes

Commonly Encountered Problems: - 15 minutes

    *  Beam Drift due to Substrate Charging issues and discussion on
      methods
    * Write Field Alignment Challenges and how to solve them.
    * Stitching breaks in the V scan direction
      - To use or not to use Focus Correction By working distance.

New Item: Raith Champions End of Year Project Summaries:
Raith Champions are encouraged to briefly summarize their project goals 
and review the results they have obtained on the RAITH system. It is 
desired for you to present a PPT slide or two with your images and 
measurements to summarize your RAITH results.  User feedback is 
requested on what needs improvement and desired hardware upgrades and 
software enhancements might be desired by Users.

On the lighter side Users are also encouraged to present your best 
images and unusual results you may have obtained on the system ion the last year. 
Presenters will meet their results and project reporting requirement for 
SNF by giving us your update.


RSVP your plan to attend and/or present to beamtools@snf.stanford.edu  
Thread:  EBEAM TOWN HALL MEETING.

Thanking you for your support,

James Conway




Greetings Ebeam Lab Users:

The proposed date for the next Ebeam Town Meeting is Friday January 21, 2004 2 -4 PM in CIS 101
The Agenda remains open for your suggestions and additions:

Agenda Items:

Raith Scheduling on Coral; managing a limited resource. 20 minutes
    Seeking your contributions and opinions on our current usage 
policies and discussion and proposals of modifications to these policies.

Discussions on methods users can implement to increase sample throughput 
on the system. 10 minutes

Recent PCM testing results in brief. - 5 minutes

Commonly Encountered Problems: - 15 minutes

    *  Beam Drift due to Substrate Charging issues and discussion on
      methods
    * Write Field Alignment Challenges and how to solve them.
    * Stitching breaks in the V scan direction
      - To use or not to use Focus Correction By working distance.

New Item: Raith Champions End of Year Project Summaries:
Raith Champions are encouraged to briefly summarize their project goals 
and review the results they have obtained on the RAITH system. It is 
desired for you to present a PPT slide or two with your images and 
measurements to summarize your RAITH results.  User feedback is 
requested on what needs improvement and desired hardware upgrades and 
software enhancements might be desired by Users.

On the lighter side Users are also encouraged to present your best 
images and unusual results you may have obtained on the system ion the last year. 
Presenters will meet their results and project reporting requirement for 
SNF by giving us your update.


RSVP your plan to attend and/or present to beamtools@snf.stanford.edu  
Thread:  EBEAM TOWN HALL MEETING.

Thanking you for your support,

James Conway