Greetings Ebeam and Raith Users:

This morning I stocked 2% 950K Molecular Weight and 5% 495K Molecular 
Weight PMMA based in ANISOLE solvent into the solvent cabinet located in 
the chase of  the SNF Cleanroom.  These materials are plainly labeled 
with a letter 'A" following their product name and highlighted with 
different colored ID stickers on the Jar Cap.

Users are encouraged to begin to utilize these materials and Users 
should check their process parameters for their specific application.  I 
will be working with these materials this week and next, and will post 
my thickness function of spin speed data to these discussion list once 
they have been tested and confirmed.

Users are directed not to take individual stocks of these materials from 
the SNF SUPPLIED BOTTLES.
SNF Staff desires to minimize the amounts of hazardous chemicals stored 
into the cleanroom solvent cabinets both by lab members and SNF Staff. 
Users are reminded that no chemicals whatsoever are to be taken from the 
SNF cleanroom for use in other Stanford University labs located in other 
buildings.

All Users are directed to finish up your by spinning onto wafers, or 
dispose of properly as hazardous waste all individual bottles of PMMA 
resist containing chlorobenzene stored in the cleanroom.

NO individual bottles of PMMA should be stored in the left hand solvent 
cabinet with the SNF Lab stocked PMMA.
I will be throwing out, or moving into other solvent cabinet all 
materials left in the Ebeam Lab tub at this location.  Today I moved all 
users' individual PMMA materials in small bottles to the right hand 
solvent cabinet upper left hand shelf.
In early February I will go through the solvent cabinet and remove 
and/or dispose of all chlorobenzene based resist systems stored in the 
SNF Cleanroom.

This change is made to improve your personal safety and reduce the 
potential risk of exposure to toxic and carcinogenic materials utilized 
within the SNF cleanroom. Please reply to beamtools@snf.stanford.edu to 
express your queries and concerns regarding this change.

Thank you for your support!

James Conway
SNF Ebeam Lab
650-725-7075



Greetings Ebeam and Raith Users:

This morning I stocked 2% 950K Molecular Weight and 5% 495K Molecular Weight PMMA based in ANISOLE solvent into the solvent cabinet located in the chase of  the SNF Cleanroom.  These materials are plainly labeled with a letter 'A" following their product name and highlighted with different colored ID stickers on the Jar Cap.

Users are encouraged to begin to utilize these materials and Users should check their process parameters for their specific application.  I will be working with these materials this week and next, and will post my thickness function of spin speed data to these discussion list once they have been tested and confirmed.

Users are directed not to take individual stocks of these materials from the SNF SUPPLIED BOTTLES.
SNF Staff desires to minimize the amounts of hazardous chemicals stored into the cleanroom solvent cabinets both by lab members and SNF Staff. Users are reminded that no chemicals whatsoever are to be taken from the SNF cleanroom for use in other Stanford University labs located in other buildings.

All Users are directed to finish up your by spinning onto wafers, or dispose of properly as hazardous waste all individual bottles of PMMA resist containing chlorobenzene stored in the cleanroom.

NO individual bottles of PMMA should be stored in the left hand solvent cabinet with the SNF Lab stocked PMMA.
I will be throwing out, or moving into other solvent cabinet all materials left in the Ebeam Lab tub at this location.  Today I moved all users' individual PMMA materials in small bottles to the right hand solvent cabinet upper left hand shelf.
In early February I will go through the solvent cabinet and remove and/or dispose of all chlorobenzene based resist systems stored in the SNF Cleanroom.

This change is made to improve your personal safety and reduce the potential risk of exposure to toxic and carcinogenic materials utilized within the SNF cleanroom. Please reply to beamtools@snf.stanford.edu to express your queries and concerns regarding this change.

Thank you for your support!

James Conway
SNF Ebeam Lab
650-725-7075