Subject: FAQ NO. 7 RAITH BEAM BLANKER in wrong phase or polarity. How to fix...
From: James Conway <jwc@snf.stanford.edu>
Date: Tue, 27 Jun 2006 09:14:54 -0700
Tue, 27 Jun 2006 09:14:54 -0700
Greetings Raith Users:


RE: FAQ NO. 7  RAITH BEAM BLANKER in wrong phase or polarity. How to fix...
I have been seeing this occasionally, more often recently, and it is 
normally a result of the previous user on the system whom has reversed 
his blanking state and then when the software application thinks the 
blanker is unblanked the user resets the front panel of the ELPHY+ High 
Speed Pattern Generator.

The other cause of this is if the ELPHY+ High Speed Pattern Generator is 
manually switched to beam 'on' manual control.  This is the far right 
toggle switch on the ELPHY+ High Speed Pattern Generator and it should 
always be in the UP position and not in the DOWN position ever as Randy 
found it upon coming onto the system very early this morning.

If you have managed to get your software into a reversed blanking state 
this is how to recover it and restore normal blanking functions.

In the RAITH 150 Application window confirm that the software toggle for 
Blanking indicate 'Beam Blanked'
On the ELPHY+ High Speed Pattern Generator move the  momentary toggle 
position switch on the Far left hand side upwards to 'RESET' the ELPHY+ 
High Speed Pattern Generator. The deflection indicators should center 
and the beam blanker box above it should have the 'Beam Off light' 
indicating ON and the 'Beam On light' OFF.  Then Save your project file 
to record and preserve this state for your next use.  If necessary you 
can gracefully exit and come back into the application and/or reset the 
hardware -- but normally you will not have to.

Thank you,

James Conway



Randy Stoltenberg wrote:

> James-
> I'm doing a write right now, but I don't know if it's going to work. 
> The beam blanker on the Raith side is out of phase. (On=off and vice 
> versa). I notice that as the stage translates during the write, I'm 
> still getting beam current. I don't think this is good. DOes this mean 
> I'm just exposing everything? I tried a full restart of the Raith 
> computer, but that didn't fix the problem. What should I do?
> Randy
>
> -- 
> Randy Stoltenberg
> Ph.D. Student, Department of Chemistry
> Stanford University
> Stauffer III, Room 15
> 381 North South Mall
> Stanford, CA 94305
> randalls@stanford.edu <mailto:randalls@stanford.edu>



FAQ NO. 7 RAITH BEAM BLANKER in wrong phase or polarity. How to fix... Greetings Raith Users:


RE: FAQ NO. 7  RAITH BEAM BLANKER in wrong phase or polarity. How to fix...
I have been seeing this occasionally, more often recently, and it is normally a result of the previous user on the system whom has reversed his blanking state and then when the software application thinks the blanker is unblanked the user resets the front panel of the ELPHY+ High Speed Pattern Generator.

The other cause of this is if the ELPHY+ High Speed Pattern Generator is manually switched to beam 'on' manual control.  This is the far right toggle switch on the ELPHY+ High Speed Pattern Generator and it should always be in the UP position and not in the DOWN position ever as Randy found it upon coming onto the system very early this morning.

If you have managed to get your software into a reversed blanking state this is how to recover it and restore normal blanking functions.

In the RAITH 150 Application window confirm that the software toggle for Blanking indicate 'Beam Blanked'
On the ELPHY+ High Speed Pattern Generator move the  momentary toggle position switch on the Far left hand side upwards to 'RESET' the ELPHY+ High Speed Pattern Generator. The deflection indicators should center and the beam blanker box above it should have the 'Beam Off light' indicating ON and the 'Beam On light' OFF.  Then Save your project file to record and preserve this state for your next use.  If necessary you can gracefully exit and come back into the application and/or reset the hardware -- but normally you will not have to.

Thank you,

James Conway



Randy Stoltenberg wrote:
James-
I'm doing a write right now, but I don't know if it's going to work. The beam blanker on the Raith side is out of phase. (On=off and vice versa). I notice that as the stage translates during the write, I'm still getting beam current. I don't think this is good. DOes this mean I'm just exposing everything? I tried a full restart of the Raith computer, but that didn't fix the problem. What should I do?
Randy

--
Randy Stoltenberg
Ph.D. Student, Department of Chemistry
Stanford University
Stauffer III, Room 15
381 North South Mall
Stanford, CA 94305
randalls@stanford.edu