Subject: RESCHEDULED TO NEW DATE AND TIME "Take A Spin with Me" -- Ebeam Resist Handling Training on the Headway. Tuesday April 3 2007 10:00 - 13:00
From: James Conway <jwc@snf.stanford.edu>
Date: Tue, 20 Mar 2007 09:09:42 -0800
Tue, 20 Mar 2007 09:09:42 -0800
*ANNOUNCEMENT:  "Take A Spin with Me" -- Ebeam Resist Handling Training 
on the Headway Coater.
*
Greetings Ebeam Lab Users,

I will be conducting my monthly *"Take A Spin with Me" *training class 
Tuesday April 3 from 10 AM  - 1 PM.
There is a sign up sheet posted on the white board in my office if you 
desire to sign up in advance.

This is a great opportunity for you to get acquainted with the specific 
points to employ when working with our Ebeam Resist materials in order 
to obtain high quality thin film coatings over your wafers for Electron 
Beam, Scanning Probe (SPL), and optical Nano-Lithography.
In these applications accurate control of polymer thickness is important 
in order to obtain consistent high quality lithography results.

We will be conducting this training on the Headway spin coater and users 
attending this session will gain their qualification on this tool.

Schedule of Events:

10 - 11:00 I will start with substrate cleans on WET BENCH NONMETAL 
performing Pirhana substrate cleans and HF etching of the intrinsic 
native oxide on Silicon wafers.  All users are encouraged to have their 
substrates cleaned and ready to go for spinning by the session time; 
either coming out of the 150 degree Singe oven, or if you are working on 
oxides or nitrides, coming out of the YES HMDS Prime oven.

11:00 - 12:30 We can apply what ever resist system you desire for your 
work.

12:30 - 1:00 Thin Film Measurements on the Nanospec Thin Film Analyzer

All interested parties are welcome to attend this session.  No need to 
reply to this email -- just show up!

Thank you for your interest in Ebeam Technologies here at Stanford 
Nanofabrication Facility,

James W. Conway
Ebeam Technology Group
Stanford Nanofabrication Facility
650-725-7075  office hour M-F 8:30 - 9:30 AM CIS 31



ANNOUNCEMENT:  "Take A Spin with Me" -- Ebeam Resist Handling Training on the Headway Coater.

Greetings Ebeam Lab Users,

I will be conducting my monthly
"Take A Spin with Me" training class Tuesday April 3 from 10 AM  - 1 PM.
There is a sign up sheet posted on the white board in my office if you desire to sign up in advance.

This is a great opportunity for you to get acquainted with the specific points to employ when working with our Ebeam Resist materials in order to obtain high quality thin film coatings over your wafers for Electron Beam, Scanning Probe (SPL), and optical Nano-Lithography.
In these applications accurate control of polymer thickness is important in order to obtain consistent high quality lithography results.

We will be conducting this training on the Headway spin coater and users attending this session will gain their qualification on this tool.

Schedule of Events:

10 - 11:00 I will start with substrate cleans on WET BENCH NONMETAL performing Pirhana substrate cleans and HF etching of the intrinsic native oxide on Silicon wafers.  All users are encouraged to have their substrates cleaned and ready to go for spinning by the session time; either coming out of the 150 degree Singe oven, or if you are working on oxides or nitrides, coming out of the YES HMDS Prime oven.

11:00 - 12:30 We can apply what ever resist system you desire for your work.

12:30 - 1:00 Thin Film Measurements on the Nanospec Thin Film Analyzer

All interested parties are welcome to attend this session.  No need to reply to this email -- just show up!

Thank you for your interest in Ebeam Technologies here at Stanford Nanofabrication Facility,

James W. Conway
Ebeam Technology Group
Stanford Nanofabrication Facility
650-725-7075  office hour M-F 8:30 - 9:30 AM CIS 31