Subject: ANNOUNCEMENT: RAITH Group XXVI -- Intensive 4 day short course. April 17 - 20, 2007 TUESDAY - FRIDAY 10 AM - 6 PM
From: James Conway <jwc@snf.stanford.edu>
Date: Thu, 12 Apr 2007 10:05:44 -0700
Thu, 12 Apr 2007 10:05:44 -0700
*Greetings RAITH Group XXVI:

**
If you are listed in the To: section of this email you are confirmed to 
be in RAITH Group** XXIV**.
If you are listed in the CC: section of this email; I still am in need 
of further information or a commitment from you, and hope to add you in 
the next class. Any RAITH user wishing to attend are also welcome if you 
desire a review of operations on the RAITH system.
**
We wish to invite all interested parties to the Tuesday morning lecture 
session and demo layer one training following at 2 PM - 6 PM in the 
afternoon. All are also welcome to attend as observers the other 
'hands-on' sessions through the week.
All Users are  encouraged to join any Raith Champion when they are on 
the system to gain further exposure to the system.
*
*If you are listed in the To: section of this email:
*This is your first reminder and confirmation of your commitment for 
attending the RAITH Group XXIV Training course to be held April 17 - 20, 
2007.
The schedule follows along with a listing of Participants whom you will 
be working with as a Team.  This will be an intensive four day workshop. _
*You are expected to attend all sessions in order to gain the experience 
and skills you will need to qualify on the RAITH 150 system.*

_*NOTE:* *_There are prerequisites you must complete before attending 
this class:_*
You must have recent relevant SEM and LITHO experience before your can 
sit for this class. Please see me directly during my office hour if you 
have any questions.
*Please bring examples of your best high resolution SEM work to the 
first class.**
If you don't have intermediate SEM operations experience you will be 
dropped from this class. *

Users are also encouraged to attend the *"Take a Spin with Me"* class 
covering Ebeam Resist handling procedures.
Next class is to be scheduled in the weeks after your RAITH Class. There 
is a separate sign up for this class on the white board in my office at 
CIS 31.

Thank you for your interest in Electron Beam Technologies at the 
Stanford Nanofabrication Facility,

James Conway
Ebeam Technology Group
650-725-7075
---------------------------------

*   **RAITH Group** XXVI** Schedule: **   *

*Raith 150 Basic Users Training – Intensive 4 Day Short Course*

*April 17 - 20, 2007 from 10 - 6 PM Tuesday through Friday.*

*The Plan of Action:
*We will start out with a half day of lecture in the morning Tuesday; 
quickly moving into entirely 'hands on' operations training through the 
remainder of the week.
We will break for lunch at various times, while the system is writing, 
so plan to be flexible with your other outside commitments.  You should 
have started working on your GDS II patterns and preparing PMMA on your 
substrates if you wish to write on your material. Please bring your 
patterns and materials to the 'Hands-On' sessions. Some afternoons we 
may also be able to finish earlier,  letting the system write on its own 
to the end of our reservations on the system.*
*

* Schedule:*
Tuesday April 17, 2007:
10:00 - 12:30   Session 1:  Basic Users Course Lecture  -- CIS-X 201
14:00 - 17:00  Session 2:  RAITH System Demonstration - Layer One -- 
EBEAM LAB CIS L104

Wednesday April 18, 2007:
10:00 - 12:30 Session 3:  RAITH System Demonstration - Layer Two: 
OVERLAY -- EBEAM LAB CIS L104
14:00 - 18:00 Session 4:  Hands On training session One -- EBEAM LAB CIS 
L104

Thursday April 19, 2007:
10:00 - 12:30 Session 5: Hands On training session Two -- EBEAM LAB CIS L104
14:00 - 18:00 Session 6: Hands On training session Three -- EBEAM LAB 
CIS L104

Friday April 20, 2007:
10:00 - 12:30 Session 7: Hands On training session Four -- EBEAM LAB CIS 
L104
14:00 - 18:00 Session 8: Hands On training session Five -- EBEAM LAB CIS 
L104

Individual Qualification Sessions will be held after this class where- 
you can demonstrate your skill on the system to me and gain your login 
to the system.


I CAN PROVIDE A CD AND PRINTED MATERIALS AT THE FIRST MEETING, IF YOU 
HAVE NOT ALREADY RECEIVED ONE YET.
You can stop by my office hour and pick up a copy of these training 
materials during my daily office hour. (8:30 - 9:30 AM CIS 31)

-------------------------------------------------------------------------------------------------------------------------------------------

*RAITH Group XXVI  Date April 17 –20, 2007
BASIC USER INTENSIVE FOUR DAY SHORT COURSE.*

1.   Leili Baghaei Rad leili@stanford.edu <mailto:leili@stanford.edu> 
Coral: leili
Pease Group Project: Digital reconstruction of SEM Images.

2.   Susan Clark sclark4@stanford.edu <mailto:sclark4@stanford.edu> 
Coral: sclark4
Yamamoto Group Project: Mesa and waveguide on Qdot. InAs

3.   Kosar Baghbani Parizi kosarb@stanford.edu 
<mailto:kosarb@stanford.edu> Coral: kosarb
Nishi Group Project: Bio-FET on SOI.

4.   Vanessa Sih vsih@stanford.edu <mailto:vsih@stanford.edu> Coral: 
vsih Vuckovic
Group Project: Photonic Crystals in Si.

5. Byoung Il bilee@stanford.edu <mailto:bilee@stanford.edu> Coral: bilee
H.S. Phillip Wong Group Project: Non-Volatile Memory Project.

6. Justin White whitejs@stanford.edu <mailto:whitejs@stanford.edu> 
Coral: whitejs
Brongersma Group Project: surface plasmon enhanced detectors.

Observers in this class in preparation for RAITH Group XXVII:

7. Kyeongran Yoo raneeyoo@stanford.edu <mailto:raneeyoo@stanford.edu> 
Coral: raneeyoo
Phillip Wong Group, Project: moving channel MEMS Device

8. J. Brian Leen  bleen@stanford.edu <mailto:bleen@stanford.edu> Coral:  
bleen
 Hesselink Group Project:  C Apertures for optical confinement.

 










["multipart/related" not shown]
Greetings RAITH Group XXVI:


If you are listed in the To: section of this email you are confirmed to be in RAITH Group
XXIV.
If you are listed in the CC: section of this email; I still am in need of further information or a commitment from you, and hope to add you in the next class. Any RAITH user wishing to attend are also welcome if you desire a review of operations on the RAITH system.

We wish to invite all interested parties to the Tuesday morning lecture session and demo layer one training following at 2 PM - 6 PM in the afternoon. All are also welcome to attend as observers the other 'hands-on' sessions through the week.
All Users are  encouraged to join any Raith Champion when they are on the system to gain further exposure to the system.

If you are listed in the To: section of this email:
This is your first reminder and confirmation of your commitment for attending the RAITH Group XXIV Training course to be held April 17 - 20, 2007.
The schedule follows along with a listing of Participants whom you will be working with as a Team.  This will be an intensive four day workshop.
You are expected to attend all sessions in order to gain the experience and skills you will need to qualify on the RAITH 150 system.

NOTE: There are prerequisites you must complete before attending this class:
You must have recent relevant SEM and LITHO experience before your can sit for this class. Please see me directly during my office hour if you have any questions.
Please bring examples of your best high resolution SEM work to the first class.
If you don't have intermediate SEM operations experience you will be dropped from this class.


Users are also encouraged to attend the "Take a Spin with Me" class covering Ebeam Resist handling procedures.
Next class is to be scheduled in the weeks after your RAITH Class. There is a separate sign up for this class on the white board in my office at CIS 31.

Thank you for your interest in Electron Beam Technologies at the Stanford Nanofabrication Facility,

James Conway
Ebeam Technology Group
650-725-7075
---------------------------------

   RAITH Group XXVI Schedule:   

Raith 150 Basic Users Training – Intensive 4 Day Short Course

April 17 - 20, 2007 from 10 - 6 PM Tuesday through Friday.

The Plan of Action:
We will start out with a half day of lecture in the morning Tuesday; quickly moving into entirely 'hands on' operations training through the remainder of the week.
We will break for lunch at various times, while the system is writing, so plan to be flexible with your other outside commitments.  You should have started working on your GDS II patterns and preparing PMMA on your substrates if you wish to write on your material. Please bring your patterns and materials to the 'Hands-On' sessions. Some afternoons we may also be able to finish earlier,  letting the system write on its own to the end of our reservations on the system.

Schedule:
Tuesday April 17, 2007:
10:00 - 12:30   Session 1:  Basic Users Course Lecture  -- CIS-X 201
14:00 - 17:00  Session 2:  RAITH System Demonstration - Layer One -- EBEAM LAB CIS L104

Wednesday April 18, 2007:
10:00 - 12:30 Session 3:  RAITH System Demonstration - Layer Two: OVERLAY -- EBEAM LAB CIS L104
14:00 - 18:00 Session 4:  Hands On training session One -- EBEAM LAB CIS L104

Thursday April 19, 2007:
10:00 - 12:30 Session 5: Hands On training session Two -- EBEAM LAB CIS L104
14:00 - 18:00 Session 6: Hands On training session Three -- EBEAM LAB CIS L104

Friday April 20, 2007:
10:00 - 12:30 Session 7: Hands On training session Four -- EBEAM LAB CIS L104
14:00 - 18:00 Session 8: Hands On training session Five -- EBEAM LAB CIS L104

Individual Qualification Sessions will be held after this class where- you can demonstrate your skill on the system to me and gain your login to the system.


I CAN PROVIDE A CD AND PRINTED MATERIALS AT THE FIRST MEETING, IF YOU HAVE NOT ALREADY RECEIVED ONE YET.
You can stop by my office hour and pick up a copy of these training materials during my daily office hour. (8:30 - 9:30 AM CIS 31)

-------------------------------------------------------------------------------------------------------------------------------------------

RAITH Group XXVI  Date April 17 –20, 2007
BASIC USER INTENSIVE FOUR DAY SHORT COURSE.

1.   Leili Baghaei Rad leili@stanford.edu Coral: leili
Pease Group Project: Digital reconstruction of SEM Images.

2.   Susan Clark sclark4@stanford.edu Coral: sclark4
Yamamoto Group Project: Mesa and waveguide on Qdot. InAs

3.   Kosar Baghbani Parizi kosarb@stanford.edu Coral: kosarb
Nishi Group Project: Bio-FET on SOI.

4.   Vanessa Sih vsih@stanford.edu Coral: vsih Vuckovic
Group Project: Photonic Crystals in Si.

5. Byoung Il bilee@stanford.edu Coral: bilee
H.S. Phillip Wong Group Project: Non-Volatile Memory Project.

6. Justin White whitejs@stanford.edu Coral: whitejs
Brongersma Group Project: surface plasmon enhanced detectors.

Observers in this class in preparation for RAITH Group XXVII:

7. Kyeongran Yoo raneeyoo@stanford.edu Coral: raneeyoo
Phillip Wong Group, Project: moving channel MEMS Device

8. J. Brian Leen  bleen@stanford.edu Coral:  bleen
 Hesselink Group Project:  C Apertures for optical confinement.

 









["image/gif" not shown]