Subject: Stanford Raith system is up for Users --- **** README: Special Cautions using the Universal Sample Holder. ****
From: James Conway <jwc@snf.stanford.edu>
Date: Thu, 09 Aug 2007 19:52:18 -0700
Thu, 09 Aug 2007 19:52:18 -0700
*Greetings Raith Users,*

I am relieved to report the planned repairs have been completed on schedule:

    * Neslab chiller was replaced with the old rebuilt unit.  Flow
      through the system cooling  is 2 liters per minute (.4 gpm)
    * The new Universal Sample Holder (USH) on loan from RAITH USA has
      been tested and the pallet is level to within 1 to 2 um across a
      90 mm axis in U and V.

*READ ME:

*
*Special Cautions prescribed for use of the Universal Sample Holder:*
*
*
The surface of this sample holder has a excellent surface finish and 
will allow precision placement and leveling of the USH to yield the 
optimal focus plane conditions for your EBL Writes.

ALL USERS SHOULD MOUNT THEIR SAMPLES AND HANDLE THIS ACCESSORY WITH 
GREAT CARE SO AS TO NOT SCRATCH OR DEFORM THE SURFACE.  ONLY TEFLON 
COATED SS OR PLASTIC TWEEZERS ARE TO BE USED WHEN LOADING SAMPLES. ALL 
SAMPLES ARE TO BE PLACED CAREFULLY DOWN ONTO THE USH AND WITHOUT SLIDING 
WAFERS, AND ESPECIALLY SMALLER CHIPS AND IRREGULAR SAMPLES, ACROSS THE 
USH'S SURFACE. PLEASE MAKE EVERY EFFORT POSSIBLE TO NOT SCRATCH THIS 
FIXTURE.

The older standard sample holder is on top of the system if you wish to 
use it for your writes if you cannot load onto the USH or do not wish to 
risk scratching it.

Several Qualification exposure  were completed on 300 nm 5% 950K PMMA 
and I will be performing a full PCM Qualification  on 100 nm resist 
tomorrow morning during the 10 AM - 2 PM session.  Todays exposure 
result passed qualification. Users desiring project or application 
support, or seeking further fine tuning or training, are welcome to join 
me and 'Share the Ride' during this session.

Thank you for your interest in Ebeam Technologies here at the SNF!

Good Evening,

James Conway
:-)




Greetings Raith Users,

I am relieved to report the planned repairs have been completed on schedule:

READ ME:

Special Cautions prescribed for use of the Universal Sample Holder:

The surface of this sample holder has a excellent surface finish and will allow precision placement and leveling of the USH to yield the optimal focus plane conditions for your EBL Writes.

ALL USERS SHOULD MOUNT THEIR SAMPLES AND HANDLE THIS ACCESSORY WITH GREAT CARE SO AS TO NOT SCRATCH OR DEFORM THE SURFACE.  ONLY TEFLON COATED SS OR PLASTIC TWEEZERS ARE TO BE USED WHEN LOADING SAMPLES. ALL SAMPLES ARE TO BE PLACED CAREFULLY DOWN ONTO THE USH AND WITHOUT SLIDING WAFERS, AND ESPECIALLY SMALLER CHIPS AND IRREGULAR SAMPLES, ACROSS THE USH'S SURFACE. PLEASE MAKE EVERY EFFORT POSSIBLE TO NOT SCRATCH THIS FIXTURE.

The older standard sample holder is on top of the system if you wish to use it for your writes if you cannot load onto the USH or do not wish to risk scratching it.

Several Qualification exposure  were completed on 300 nm 5% 950K PMMA and I will be performing a full PCM Qualification  on 100 nm resist tomorrow morning during the 10 AM - 2 PM session.  Todays exposure result passed qualification. Users desiring project or application support, or seeking further fine tuning or training, are welcome to join me and 'Share the Ride' during this session.

Thank you for your interest in Ebeam Technologies here at the SNF!

Good Evening,

James Conway
:-)