Subject: ANNOUNCEMENT: RAITH Group XXXIII -- Intensive 4 day short course for New Users August 12 - 15, 2008 TUESDAY - FRIDAY 10 AM - 6 PM
From: James Conway <jwc@snf.stanford.edu>
Date: Fri, 08 Aug 2008 15:14:06 -0700
Fri, 08 Aug 2008 15:14:06 -0700
*Greetings RAITH Group XXXIII:

**
If you are listed in the To: section of this email you are confirmed to 
be in RAITH Group** XXXIII -- the next RAITH** Four Day Basic User Short 
Course.
If you are listed in the CC: section of this email, I am** still ** in 
need of further information, or a commitment from you, and hope to add 
you in the next class and or finish your previous training. Then in 
following month I hope to provide you with further hands on training and 
get you all qualified as users on the system.
Any RAITH users wishing to attend are also welcome if you desire a 
review of operations on the RAITH 150 system.
**
We wish to invite all interested parties to the Tuesday morning lecture 
session from 10:00 AM  - 12:30 PM,  and the following Demo Layer One 
training from 2 PM - 6 PM in the afternoon.  All others are also welcome 
to attend as observers the other 'Hands-On' sessions through the week.
*
*If you are listed in the To: section of this email:
*This is your first reminder and confirmation of your commitment for 
attending the RAITH Group XXXIII Training course to be held next week on 
August 12 - 15 2008
_*You are expected to attend all sessions in order to gain the 
experience and skills you will need to qualify on the RAITH 150 system.*

_Users are also encouraged to attend the *"Take a Spin with Me"* 
<http://snf.stanford.edu/cgi-bin/ezmlm-cgi?430:mss:73:200801:bleokmmlinkjilfgnknc> 
class covering Ebeam Resist handling procedures. I am next holding this 
class on August 19th from 10:15 - 12:30 PM in the SNF cleanroom.

Thank you for your interest in Electron Beam Technologies at the 
Stanford Nanofabrication Facility,

James Conway
Ebeam Technology Group
650-725-7075
---------------------------------

*   **RAITH Group** XXXIII **Schedule: **   *

*Raith 150 Basic Users Training -- Intensive 4 Day Short Course*

*August 12 - 15, 2008 from 10 - 6 PM Tuesday through Friday.*

*The Plan of Action:
*We will start out with a half day of lecture in the morning Tuesday; 
quickly moving into entirely 'hands on' operations training through the 
remainder of the week.
We will break for lunch at various times, while the system is writing, 
so plan to be flexible with your other outside commitments.  You should 
have started working on your GDS II patterns and preparing PMMA on your 
substrates if you wish to write on your material. Please bring your 
patterns and materials to the 'Hands-On' sessions. Some afternoons we 
may also be able to finish earlier,  letting the system write on its own 
to the end of our reservations on the system.*
*

* Schedule:*
Tuesday August 12, 2008:
10:00 - 12:30   Session 1:  Basic Users Course Lecture  -- CIS 101
14:00 - 17:00  Session 2:  RAITH System Demonstration - Layer One -- 
EBEAM LAB CIS L104

Wednesday August 13, 2008:
10:00 - 12:30 Session 3:  RAITH System Demonstration - Layer Two: 
OVERLAY -- EBEAM LAB CIS L104
14:00 - 18:00 Session 4:  Hands On training session One -- EBEAM LAB CIS 
L104

Thursday August 14, 2008:
10:00 - 12:30 Session 5: Hands On training session Two -- EBEAM LAB CIS L104
14:00 - 18:00 Session 6: Hands On training session Three -- EBEAM LAB 
CIS L104

Friday August 15, 2008:
10:00 - 12:30 Session 7: Hands On training session Four -- EBEAM LAB CIS 
L104
14:00 - 18:00 Session 8: Hands On training session Five -- EBEAM LAB CIS 
L104

Individual Qualification Sessions will be held after this class where 
you can demonstrate your skill on the system to me and gain your login 
to the system.


I CAN PROVIDE A CD AND PRINTED MATERIALS AT THE FIRST MEETING, IF YOU 
HAVE NOT ALREADY RECEIVED ONE YET.
You can stop by my office hour and pick up a copy of these training 
materials during my daily office hour. (8:30 - 9:30 AM CIS 31) Just 
bring along a USB drive!

-------------------------------------------------------------------------------------------------------------------------------------------

RAITH Group XXXIII -- Date August 12 -- 15, 2008

 

1. Julie Bert jbert@stanford.edu <mailto:jbert@stanford.edu>  Coral: jbert

Moler Project:  Au and AL rings for persistent current measurements.

2. Donkoun Lee dlee76@stanford.edu <mailto:dlee76@stanford.edu> Coral: 
dlee76 

Shan Wang Group Project:  Spin Torque

 

3.  Lisa Chen lisachen@stanford.edu <mailto:lisachen@stanford.edu> 
Coral: lisachen

Shan Wang Group Project E341 Spin FET 

?

4. SangMoo Jeong popomoo@stanford.edu <mailto:popomoo@stanford.edu>  
Coral: popomoo

Yi Cui Group Project:  Nano-structured Solar Cell -- fabricate 3 mm 
cones on QZ.

?

5. Hailin Peng hlpeng@stanford.edu <mailto:hlpeng@stanford.edu> Coral:  
hlpeng 

Yi Cui Group Project:  Nano-structured Solar Cell -- single NW solar 
cell CuInSe2.

Observers Group:










["multipart/related" not shown]
Greetings RAITH Group XXXIII:


If you are listed in the To: section of this email you are confirmed to be in RAITH Group
XXXIII -- the next RAITH Four Day Basic User Short Course.
If you are listed in the CC: section of this email, I am
still in need of further information, or a commitment from you, and hope to add you in the next class and or finish your previous training. Then in following month I hope to provide you with further hands on training and get you all qualified as users on the system.
Any RAITH users wishing to attend are also welcome if you desire a review of operations on the RAITH 150 system.

We wish to invite all interested parties to the Tuesday morning lecture session from 10:00 AM  - 12:30 PM,  and the following Demo Layer One training from 2 PM - 6 PM in the afternoon.  All others are also welcome to attend as observers the other 'Hands-On' sessions through the week.

If you are listed in the To: section of this email:
This is your first reminder and confirmation of your commitment for attending the RAITH Group XXXIII Training course to be held next week on August 12 - 15 2008
You are expected to attend all sessions in order to gain the experience and skills you will need to qualify on the RAITH 150 system.

Users are also encouraged to attend the "Take a Spin with Me" class covering Ebeam Resist handling procedures. I am next holding this class on August 19th from 10:15 - 12:30 PM in the SNF cleanroom.

Thank you for your interest in Electron Beam Technologies at the Stanford Nanofabrication Facility,

James Conway
Ebeam Technology Group
650-725-7075
---------------------------------

   RAITH Group XXXIII Schedule:   

Raith 150 Basic Users Training – Intensive 4 Day Short Course

August 12 - 15, 2008 from 10 - 6 PM Tuesday through Friday.

The Plan of Action:
We will start out with a half day of lecture in the morning Tuesday; quickly moving into entirely 'hands on' operations training through the remainder of the week.
We will break for lunch at various times, while the system is writing, so plan to be flexible with your other outside commitments.  You should have started working on your GDS II patterns and preparing PMMA on your substrates if you wish to write on your material. Please bring your patterns and materials to the 'Hands-On' sessions. Some afternoons we may also be able to finish earlier,  letting the system write on its own to the end of our reservations on the system.

Schedule:
Tuesday August 12, 2008:
10:00 - 12:30   Session 1:  Basic Users Course Lecture  -- CIS 101
14:00 - 17:00  Session 2:  RAITH System Demonstration - Layer One -- EBEAM LAB CIS L104

Wednesday August 13, 2008:
10:00 - 12:30 Session 3:  RAITH System Demonstration - Layer Two: OVERLAY -- EBEAM LAB CIS L104
14:00 - 18:00 Session 4:  Hands On training session One -- EBEAM LAB CIS L104

Thursday August 14, 2008:
10:00 - 12:30 Session 5: Hands On training session Two -- EBEAM LAB CIS L104
14:00 - 18:00 Session 6: Hands On training session Three -- EBEAM LAB CIS L104

Friday August 15, 2008:
10:00 - 12:30 Session 7: Hands On training session Four -- EBEAM LAB CIS L104
14:00 - 18:00 Session 8: Hands On training session Five -- EBEAM LAB CIS L104

Individual Qualification Sessions will be held after this class where you can demonstrate your skill on the system to me and gain your login to the system.


I CAN PROVIDE A CD AND PRINTED MATERIALS AT THE FIRST MEETING, IF YOU HAVE NOT ALREADY RECEIVED ONE YET.
You can stop by my office hour and pick up a copy of these training materials during my daily office hour. (8:30 - 9:30 AM CIS 31) Just bring along a USB drive!

-------------------------------------------------------------------------------------------------------------------------------------------

RAITH Group XXXIII -- Date August 12 – 15, 2008

 

1. Julie Bert jbert@stanford.edu  Coral: jbert

Moler Project:  Au and AL rings for persistent current measurements.

2. Donkoun Lee dlee76@stanford.edu Coral: dlee76 

Shan Wang Group Project:  Spin Torque

 

3.  Lisa Chen lisachen@stanford.edu Coral: lisachen

Shan Wang Group Project E341 Spin FET 

4. SangMoo Jeong popomoo@stanford.edu  Coral: popomoo

Yi Cui Group Project:  Nano-structured Solar Cell – fabricate 3 mm cones on QZ.

5. Hailin Peng hlpeng@stanford.edu Coral:  hlpeng 

Yi Cui Group Project:  Nano-structured Solar Cell – single NW solar cell CuInSe2.

Observers Group:









["image/gif" not shown]