Subject: JWC is on the Raith tool this afternoon starting at 2:30 until 6 PM examining HSQ negative tone EBL resist and RIE structures. Good introduction to the RAITH 150 SEM package...
From: James Conway <jwc@snf.stanford.edu>
Date: Thu, 09 Apr 2009 09:36:29 -0700
Thu, 09 Apr 2009 09:36:29 -0700
Good Morning Future Raith 150 Users:

As I mentioned to each of you in the recent past.  I operate the ebeam 
lab as an open lab resource for Users.  You are welcome to join either 
myself or any other Raith User, preferably a Raith Champion, to gain 
exposure to and even get exposure performed on the system.  This is a 
great way to get up to speed on the system before the next class in 
May.  I have scheduled this class for the week of May 12 to 15th, 2009 
from 10 to 6 PM each day.  Please put this on your schedules if you will 
be able to attend the class.

I look forward to getting your projects started while working together 
and  learning more about your research here at SNF in the coming weeks 
before the class.

Announcement:  This afternoon Thursday April 09, 2009 from 2:30 until 
roughly 6 PM, I will be working on the RAITH performing a inspection of 
HSQ negative tone resist EBL writes and RIE etch structures on Silicon.  
This will include some low voltage SEM work to evaluate resist etching 
characterization of thin and  normal specification thicknesses of this 
material to evaluate how well its survives the RIE etching in the P-5000 
MERIE system.  During this time I will be working at multiple 
acceleration voltages and with different SEM control settings and it 
would be a good introduction to the SEM side of the package if you are 
available.

Everyone of interest is welcome to attend any of my sessions.

Best,

James Conway






Good Morning Future Raith 150 Users:

As I mentioned to each of you in the recent past.  I operate the ebeam lab as an open lab resource for Users.  You are welcome to join either myself or any other Raith User, preferably a Raith Champion, to gain exposure to and even get exposure performed on the system.  This is a great way to get up to speed on the system before the next class in May.  I have scheduled this class for the week of May 12 to 15th, 2009 from 10 to 6 PM each day.  Please put this on your schedules if you will be able to attend the class.

I look forward to getting your projects started while working together and  learning more about your research here at SNF in the coming weeks before the class.

Announcement:  This afternoon Thursday April 09, 2009 from 2:30 until roughly 6 PM, I will be working on the RAITH performing a inspection of HSQ negative tone resist EBL writes and RIE etch structures on Silicon.  This will include some low voltage SEM work to evaluate resist etching characterization of thin and  normal specification thicknesses of this material to evaluate how well its survives the RIE etching in the P-5000 MERIE system.  During this time I will be working at multiple acceleration voltages and with different SEM control settings and it would be a good introduction to the SEM side of the package if you are available.

Everyone of interest is welcome to attend any of my sessions.

Best,

James Conway