Subject: Re: raith beam On/Off malfunction
From: "James W. Conway" <jwc@snf.stanford.edu>
Date: Tue, 09 Feb 2010 09:50:13 -0800

This could also be due having the application unblanked when you perform 
an ungraceful exit from the RAITH 150 application.

To correct Login on your login, blank the blanker and exit.

You should be OK now when you come back in.

Best

James Conway



Yiyang Gong wrote:
> I think this has been fixed.
>
> Yiyang
>
> ----- Original Message -----
> From: "Dany Ly-Gagnon" <dalyx@stanford.edu>
> To: "Hyung Dong Lee" <hdonglee@stanford.edu>
> Cc: "raith" <raith@snf.stanford.edu>
> Sent: Monday, February 8, 2010 7:23:22 PM GMT -08:00 US/Canada Pacific
> Subject: Re: raith beam On/Off malfunction
>
> FYI:
> This problem can happen when somebody flips the switch by accident on the RAITH hardware
(close to the load lock). There's some info in the RAITH frequently asked questions
notebooks lying on the RAITH table on which switch to check if that happens.
>
> Best,
>
> Dany
>
> ----- Original Message -----
> From: "Hyung Dong Lee" <hdonglee@stanford.edu>
> To: "raith" <raith@snf.stanford.edu>
> Sent: Monday, February 8, 2010 5:45:12 PM GMT -08:00 US/Canada Pacific
> Subject: raith beam On/Off malfunction
>
> Dear Raith users,
>
> I have found that Beam ON/Off in raith malfunctions.
> Beam is actually ON when it is "Beam Off" and vice versa.
>
> Best,
>
> Hyung Dong Lee
>