Subject: Oral Exam Announcement: Gary Shambat
From: Gary Shambat <gshambat@stanford.edu>
Date: Sun, 28 Oct 2012 18:52:53 -0700 (PDT)
Sun, 28 Oct 2012 18:52:53 -0700 (PDT)



Ph.D. Dissertation Defense for Gary Shambat 


Title: 
From solid state to soft matter: 
Photonic nanocavities as advanced optoelectronic devices and single-cell biomedical
probes 


Advisor: Professor Jelena Vučković 
Department of Electrical Engineering 

Thursday, November 8 th 2012 
10:00 AM 
(Refreshments at 9:45 AM) 

Location: Clark Auditorium (outside entrance at the very center of Clark building )






Abstract: 

Photonic nanocavities are wavelength-scale dielectric structures that possess remarkable
properties due to their intrinsic small sizes and high quality factors. Simply by modifying
the device materials and optical properties, one can realize nanocavities for diverse
applications ranging from lasers to quantum optics and even biosensing. In this talk
I will present two drastically different functions of nanocavities, both of which make
them more practical for real-world adoption. 

The first half of my presentation will focus on how photonic crystal (PC) cavities can
be utilized for ultra-low energy and ultra-fast optical sources for next-generation
communications. To date, the true power of these nanocavities has only been demonstrated
by using secondary optical control, preventing realistic integration of devices with
electronics. We have therefore developed a new platform for efficiently driving PC cavities
using a lithographically defined, lateral p-i-n junction. With our lateral junction
we have demonstrated a world record low threshold laser with a threshold power of only
208 nW at 50K. At room temperature we find that these same devices behave as ultra-fast
light-emitting diodes which can be directly modulated at up to 10 GHz. Additional active
photonic devices incorporating a lateral junction will also be discussed. 

The second half of my talk describes the demonstration of a whole new class of tools
that marry PC cavities to the tips of optical fibers. The form factor of the optical
fiber lends itself to operation of the tool in exotic environments never before accessible
to a nanocavity. Specifically we have used our probes to interrogate single human prostate
cells with internalized PC cavities showing, for the first time, resonant photonic modes
inside biological cells. The beams can be loaded in cells and tracked for days at a
time, with cells undergoing regular division and migration. Furthermore, we present
in vitro label-free protein sensing with our probes as a path towards quantitative,
real-time biomarker detection in single cells. 



Ph.D. Dissertation Defense for Gary Shambat


Title:

From solid state to soft matter: 

Photonic nanocavities as advanced optoelectronic devices and single-cell biomedical probes


Advisor: Professor Jelena Vučković

Department of Electrical Engineering

 

Thursday, November 8th 2012

10:00 AM

(Refreshments at 9:45 AM)

 

Location: Clark Auditorium (outside entrance at the very center of Clark building)

 

 

Abstract:

 

Photonic nanocavities are wavelength-scale dielectric structures that possess remarkable properties due to their intrinsic small sizes and high quality factors. Simply by modifying the device materials and optical properties, one can realize nanocavities for diverse applications ranging from lasers to quantum optics and even biosensing. In this talk I will present two drastically different functions of nanocavities, both of which make them more practical for real-world adoption.   

 

The first half of my presentation will focus on how photonic crystal (PC) cavities can be utilized for ultra-low energy and ultra-fast optical sources for next-generation communications. To date, the true power of these nanocavities has only been demonstrated by using secondary optical control, preventing realistic integration of devices with electronics. We have therefore developed a new platform for efficiently driving PC cavities using a lithographically defined, lateral p-i-n junction. With our lateral junction we have demonstrated a world record low threshold laser with a threshold power of only 208 nW at 50K. At room temperature we find that these same devices behave as ultra-fast light-emitting diodes which can be directly modulated at up to 10 GHz. Additional active photonic devices incorporating a lateral junction will also be discussed.

 

The second half of my talk describes the demonstration of a whole new class of tools that marry PC cavities to the tips of optical fibers. The form factor of the optical fiber lends itself to operation of the tool in exotic environments never before accessible to a nanocavity. Specifically we have used our probes to interrogate single human prostate cells with internalized PC cavities showing, for the first time, resonant photonic modes inside biological cells. The beams can be loaded in cells and tracked for days at a time, with cells undergoing regular division and migration. Furthermore, we present in vitro label-free protein sensing with our probes as a path towards quantitative, real-time biomarker detection in single cells.