00: Problem raith SNF 2008-11-20 08:51:38: T axis robot arm communications issues (jwc.snf.stanford.edu)
01: Re: Problem raith SNF 2008-11-19 22:20:44: digital problems (jwc.snf.stanford.edu)
02: Re: Problem raith SNF 2008-11-20 08:51:38: T axis robot arm communications issues (jwc.snf.stanford.edu)
03: Problem raith SNF 2008-11-25 20:40:34: SEM frozen (raneeyoo.snf.stanford.edu)
04: Comment raith SNF 2008-11-25 21:03:34: SEM screen frozen (raneeyoo.snf.stanford.edu)
05: Comment raith SNF 2008-11-29 15:09:26: raith computer login error and frozen SEM (raneeyoo.snf.stanford.edu)
06: Problem raith SNF 2008-11-30 05:12:14: no image on sem, vacCheckConnectionFailed (kocabas.snf.stanford.edu)
07: Comment raith SNF 2008-11-30 05:20:32: Hissing sound (kcbalram.snf.stanford.edu)
08: Shutdown raith SNF 2008-12-01 11:43:07: too many failures to figure out -- will try to recover system this afternoon (jwc.snf.stanford.edu)
09: Re: Problem raith SNF 2008-11-25 20:40:34: SEM frozen (jwc.snf.stanford.edu)
10: Re: Comment raith SNF 2008-11-25 21:03:34: SEM screen frozen (jwc.snf.stanford.edu)
11: Re: Comment raith SNF 2008-11-29 15:09:26: raith computer login error and frozen SEM (jwc.snf.stanford.edu)
12: Problem raith SNF 2008-12-01 12:48:53: Chiller water pump failure -- no flow no volume (jwc.snf.stanford.edu)
13: Re: Comment raith SNF 2008-11-30 05:20:32: Hissing sound (jwc.snf.stanford.edu)
14: Re: Problem raith SNF 2008-11-30 05:12:14: no image on sem, vacCheckConnectionFailed (jwc.snf.stanford.edu)
15: Re: Shutdown raith SNF 2008-12-01 11:43:07: too many failures to figure out -- will try to recover system this afternoon (jwc.snf.stanford.edu)
16: Re: Problem raith SNF 2008-12-01 12:48:53: Chiller water pump failure -- no flow no volume (jwc.snf.stanford.edu)
17: Problem raith SNF 2008-12-03 15:04:19: bringing up system after flush and refill cooling loop (jwc.snf.stanford.edu)
18: Re: Problem raith SNF 2008-12-03 15:04:19: bringing up system after flush and refill cooling loop (jwc.snf.stanford.edu)
19: Problem raith SNF 2008-12-03 16:26:45: bringing up system and will be testing this evening (jwc.snf.stanford.edu)
20: Re: Problem raith SNF 2008-12-03 16:26:45: bringing up system and will be testing this evening (jwc.snf.stanford.edu)
21: Problem raith SNF 2008-12-11 08:26:50: User reports of unable to image in the 60 and 120 um apertures (jwc.snf.stanford.edu)
22: Re: Problem raith SNF 2008-12-11 08:26:50: User reports of unable to image in the 60 and 120 um apertures (jwc.snf.stanford.edu)
23: Shutdown raith SNF 2008-12-17 09:56:08: Holiday Shut shut down (jwc.snf.stanford.edu)
24: Re: Shutdown raith SNF 2008-12-17 09:56:08: Holiday Shut shut down (jwc.snf.stanford.edu)
25: Problem raith SNF 2009-01-07 13:59:40: SYSTEM IN QUALIFICATION (jwc.snf.stanford.edu)
26: Problem raith SNF 2009-01-07 16:55:00: system qualification FAILED == poor write field to write field stitching (jwc.snf.stanford.edu)
27: Re: Problem raith SNF 2009-01-07 13:59:40: SYSTEM IN QUALIFICATION (jwc.snf.stanford.edu)
28: Re: Problem raith SNF 2009-01-07 16:55:00: system qualification FAILED == poor write field to write field stitching (jwc.snf.stanford.edu)
29: Comment raith SNF 2009-01-09 14:07:36: qualification completed (jwc.snf.stanford.edu)
30: Shutdown raith SNF 2009-02-03 16:54:46: cooling loop flushing off line for three hours (jwc.snf.stanford.edu)
31: Re: Shutdown raith SNF 2009-02-03 16:54:46: cooling loop flushing off line for three hours (jwc.snf.stanford.edu)
32: Re: Comment raith SNF 2009-01-09 14:07:36: qualification completed (jwc.snf.stanford.edu)
33: Problem raith SNF 2009-02-14 05:09:08: fetal error of the light source (tkodama.snf.stanford.edu)
34: Comment raith SNF 2009-02-14 11:43:09: raith seems ok (xinranw.snf.stanford.edu)
35: Re: Problem raith SNF 2009-02-14 05:09:08: fetal error of the light source (jwc.snf.stanford.edu)
36: Re: Comment raith SNF 2009-02-14 11:43:09: raith seems ok (jwc.snf.stanford.edu)
37: Comment raith SNF 2009-02-18 14:01:09: larger than normal vibration signature evident in Ebeam Lab (jwc.snf.stanford.edu)
38: Problem raith SNF 2009-02-25 00:31:19: hysterisis in joystick (yiyang.snf.stanford.edu)
39: Re: Problem raith SNF 2009-02-25 00:31:19: hysterisis in joystick (jwc.snf.stanford.edu)
40: Re: Comment raith SNF 2009-02-18 14:01:09: larger than normal vibration signature evident in Ebeam Lab (jwc.snf.stanford.edu)
41: Problem raith SNF 2009-03-02 23:46:19: water flow down (yiyang.snf.stanford.edu)
42: Problem raith SNF 2009-03-03 01:14:16: water flow (ahazeghi.snf.stanford.edu)
43: Problem raith SNF 2009-03-03 12:04:55: Vacuum in stage chamber not ready (xutian.snf.stanford.edu)
44: Re: Problem raith SNF 2009-03-02 23:46:19: water flow down (jwc.snf.stanford.edu)
45: Re: Problem raith SNF 2009-03-03 01:14:16: water flow (jwc.snf.stanford.edu)
46: Re: Problem raith SNF 2009-03-03 12:04:55: Vacuum in stage chamber not ready (jwc.snf.stanford.edu)
47: Shutdown raith SNF 2009-03-17 09:11:52: water pump problems (jesselu.snf.stanford.edu)
48: Re: Shutdown raith SNF 2009-03-17 09:11:52: water pump problems (jwc.snf.stanford.edu)
49: Shutdown raith SNF 2009-04-13 05:05:19: Loadlock Fatal Error (bdai.snf.stanford.edu)
50: Re: Shutdown raith SNF 2009-04-13 05:05:19: Loadlock Fatal Error (jwc.snf.stanford.edu)
51: Shutdown raith SNF 2009-04-17 10:23:00: raith shut down due to repeated loadlock errors (faraon.snf.stanford.edu)
52: Re: Shutdown raith SNF 2009-04-17 10:23:00: raith shut down due to repeated loadlock errors (mtang.snf.stanford.edu)
53: Problem raith SNF 2009-04-20 22:06:30: Raith Load locked (sanaka.snf.stanford.edu)
54: Re: Problem raith SNF 2009-04-20 22:06:30: Raith Load locked (jwc.snf.stanford.edu)
55: Shutdown raith SNF 2009-04-21 12:10:14: continuing water cooling issues possible damage to Turbo PUMP (jwc.snf.stanford.edu)
56: Comment raith SNF 2009-04-22 16:53:31: chilling loop repairs completed (jwc.snf.stanford.edu)
57: Re: Comment raith SNF 2009-04-22 16:53:31: chilling loop repairs completed (jwc.snf.stanford.edu)
58: Re: Shutdown raith SNF 2009-04-21 12:10:14: continuing water cooling issues possible damage to Turbo PUMP (jwc.snf.stanford.edu)
59: Comment raith SNF 2009-04-23 09:09:04: Cooling loop flow check 9 AM 4-23-09 (jwc.snf.stanford.edu)
60: Comment raith SNF 2009-04-25 17:28:21: LREM problem - reset fixed (pgallagh.snf.stanford.edu)
61: Shutdown raith SNF 2009-05-01 11:09:29: two hour shutdown for maintenance (jwc.snf.stanford.edu)
62: Re: Shutdown raith SNF 2009-05-01 11:09:29: two hour shutdown for maintenance (jwc.snf.stanford.edu)
63: Re: Comment raith SNF 2009-04-25 17:28:21: LREM problem - reset fixed (jwc.snf.stanford.edu)
64: Re: Comment raith SNF 2009-04-23 09:09:04: Cooling loop flow check 9 AM 4-23-09 (jwc.snf.stanford.edu)
65: Comment raith SNF 2009-05-01 14:16:59: perterbations to the Ebeam noticvable in imaging (jwc.snf.stanford.edu)
66: Comment raith SNF 2009-06-15 12:11:51: manual switch for blanker switched down! (jwc.snf.stanford.edu)
67: Shutdown raith SNF 2009-07-03 12:45:53: Loadlock problem (tryon16.snf.stanford.edu)
68: Re: Shutdown raith SNF 2009-07-03 12:45:53: Loadlock problem (jwc.snf.stanford.edu)
69: Problem raith SNF 2009-07-09 07:31:11: could not set the voltage (arkam.snf.stanford.edu)
70: Re: Problem raith SNF 2009-07-09 07:31:11: could not set the voltage (jwc.snf.stanford.edu)
71: Re: Comment raith SNF 2009-06-15 12:11:51: manual switch for blanker switched down! (jwc.snf.stanford.edu)
72: Re: Comment raith SNF 2009-05-01 14:16:59: perterbations to the Ebeam noticvable in imaging (jwc.snf.stanford.edu)
73: Comment raith SNF 2009-07-22 17:03:50: NEED TO UPGRADE APPLICATION SW TO VERSION 5 (jwc.snf.stanford.edu)
74: Comment raith SNF 2009-08-02 22:48:26: crazy mouse on Leo (fanpy.snf.stanford.edu)
75: Re: Comment raith SNF 2009-08-02 22:48:26: crazy mouse on Leo (jwc.snf.stanford.edu)
76: Shutdown raith SNF 2009-08-13 11:01:18: T motor and loadlock valve errors (jesselu.snf.stanford.edu)
77: Re: Shutdown raith SNF 2009-08-13 11:01:18: T motor and loadlock valve errors (mtang.snf.stanford.edu)
78: Problem raith SNF 2009-08-17 19:05:39: T-valve & loadlock errors (mtang.snf.stanford.edu)
79: Re: Problem raith SNF 2009-08-17 19:05:39: T-valve & loadlock errors (jwc.snf.stanford.edu)
80: Shutdown raith SNF 2009-08-23 14:37:31: Fatal LoadLock Error (carterlin.snf.stanford.edu)
81: Comment raith SNF 2009-08-24 22:53:18: Update on status (mtang.snf.stanford.edu)
82: Re: Shutdown raith SNF 2009-08-23 14:37:31: Fatal LoadLock Error (mtang.snf.stanford.edu)
83: Comment raith SNF 2009-08-25 07:49:41: Watch for loadlock error (mtang.snf.stanford.edu)
84: Comment raith SNF 2009-09-14 17:01:07: Cleared a load lock error (jwc.snf.stanford.edu)
85: Re: Comment raith SNF 2009-09-14 17:01:07: Cleared a load lock error (jwc.snf.stanford.edu)
86: Re: Comment raith SNF 2009-08-25 07:49:41: Watch for loadlock error (jwc.snf.stanford.edu)
87: Re: Comment raith SNF 2009-08-24 22:53:18: Update on status (jwc.snf.stanford.edu)
88: Problem raith SNF 2009-09-21 20:24:14: LEO-SRV 32 Error (kcbalram.snf.stanford.edu)
89: Problem raith SNF 2009-09-22 06:30:27: Beam Current (arkam.snf.stanford.edu)
90: Re: Problem raith SNF 2009-09-21 20:24:14: LEO-SRV 32 Error (jwc.snf.stanford.edu)
91: Re: Problem raith SNF 2009-09-22 06:30:27: Beam Current (jwc.snf.stanford.edu)
92: RAITH at Stanford OK (James Conway)
93: Comment raith SNF 2009-09-22 15:13:04: extraction Voltage adjusted emision now normal (jwc.snf.stanford.edu)
94: Problem raith SNF 2009-09-26 18:02:23: Digital pattern Generator cannot start (carterlin.snf.stanford.edu)
95: Problem raith SNF 2009-09-27 11:07:49: (rpala.snf.stanford.edu)
96: Problem raith SNF 2009-09-27 11:10:47: No SEM image (rpala.snf.stanford.edu)
97: Re: Comment raith SNF 2009-09-22 15:13:04: extraction Voltage adjusted emision now normal (jwc.snf.stanford.edu)
98: Re: Problem raith SNF 2009-09-26 18:02:23: Digital pattern Generator cannot start (jwc.snf.stanford.edu)
99: Re: Problem raith SNF 2009-09-27 11:07:49: (jwc.snf.stanford.edu)