Date: Tue, 19 Sep 2006 16:06:23 -0700

 Several water flow and water temperature problems this afternoon caused an automatic
vent of the system chamber to air after a 1 hour time out.  I was unable to troubleshoot
and effect repairs to the NESLAB chiller before the time out initiated(60 minutes).
200 - 500 ml of  H20 was added to the chiller today to bring up to normal 'full' level.
Water flow cannot be verified to volume-- but water is flowing.
The Gun pressures are elevated and the FE-Gun trips off when we bring it up due to sudden
increases in Gun section pressures.
RAITH Field Service suggest performing a overnight bake out and will initiate a service
request with ZEISS SMT in the morning.
I expect to have this system back up and available to users tomorrow afternoon or evening
at best. 
Never a dull moment!
Thank you for your support!
James Conway