[Threads by date]
[Subscribe To List]
[List FAQ]
[SNF Home]
[SNF Archive Home]
Messages 0xx
01:
Shutdown rtagaas: RTA Ag GaAs shutdown
(
(none)
)
02:
Problem rtagaas 2004-05-29 12:27:36:
(
naiqian.snf.stanford.edu
)
03:
Comment rtagaas 2004-05-29 12:27:53:
(
naiqian.snf.stanford.edu
)
04:
Re: Comment rtagaas 2004-05-29 12:27:53:
(
rcrane.snf.stanford.edu
)
05:
Re: Problem rtagaas 2004-05-29 12:27:36:
(
rcrane.snf.stanford.edu
)
06:
Problem rtagaas SNF 2004-09-15 08:23:22: Len
(
griffin.snf.stanford.edu
)
07:
Problem rtagaas SNF 2004-09-15 08:23:22: Len
(
griffin.snf.stanford.edu
)
08:
Re: Problem rtagaas SNF 2004-09-15 08:23:22: Len
(
seymour.snf.stanford.edu
)
09:
Comment rtagaas SNF 2005-02-03 10:46:52: forming gas
(
seymour.snf.stanford.edu
)
10:
Re: Shutdown rtagaas 2000-04-05 10:14:24: RTA Ag GaAs shutdown
(
eenriquez.snf.stanford.edu
)
11:
Problem rtagaas SNF 2005-11-15 20:41:43: Can't enable rtagaas
(
wasserbauer.snf.stanford.edu
)
12:
Re: Problem rtagaas SNF 2005-11-15 20:41:43: Can't enable rtagaas
(
eenriquez.snf.stanford.edu
)
13:
Problem rtagaas SNF 2006-02-22 17:49:14: negative number on display
(
wwang.snf.stanford.edu
)
14:
Problem rtagaas SNF 2006-02-22 18:58:39: unstable reading of thermocouple
(
dfrancis.snf.stanford.edu
)
15:
Shutdown rtagaas SNF 2006-02-23 12:16:31: broken thermocouple
(
griffin.snf.stanford.edu
)
16:
Re: Shutdown rtagaas SNF 2006-02-23 12:16:31: broken thermocouple
(
eenriquez.snf.stanford.edu
)
17:
Re: Problem rtagaas SNF 2006-02-22 18:58:39: unstable reading of thermocouple
(
eenriquez.snf.stanford.edu
)
18:
Re: Problem rtagaas SNF 2006-02-22 17:49:14: negative number on display
(
eenriquez.snf.stanford.edu
)
19:
Eat to live, not live to eat
(
Blevins
)
20:
Your account access has been limited
(
Chase Card Services Online Services Team
)
21:
Shutdown rtagaas SNF 2006-03-23 16:40:31: Need low-T installed
(
griffin.snf.stanford.edu
)
22:
Re: Shutdown rtagaas SNF 2006-03-23 16:40:31: Need low-T installed
(
eenriquez.snf.stanford.edu
)
23:
Notification of Limited Account Access
(
Chase Card Services Online Services Team
)
24:
Chase Bank Notification
(
Chase Card Services Online Services Team
)
25:
Problem rtagaas SNF 2006-04-10 11:41:47: Thermal couple reading problem
(
josephchen.snf.stanford.edu
)
26:
Shutdown rtagaas SNF 2006-05-16 11:01:09: thermocouple problem
(
griffin.snf.stanford.edu
)
27:
Re: Shutdown rtagaas SNF 2006-05-16 11:01:09: thermocouple problem
(
eenriquez.snf.stanford.edu
)
28:
Problem rtagaas SNF 2006-07-20 15:59:59: negative temp display
(
jnhagemeier.snf.stanford.edu
)
29:
Problem rtagaas SNF 2006-07-26 19:45:24: thermocouple is broken
(
eunji.snf.stanford.edu
)
30:
Shutdown rtagaas SNF 2006-07-27 02:21:41: TC disconnected
(
pethe.snf.stanford.edu
)
31:
Re: Shutdown rtagaas SNF 2006-07-27 02:21:41: TC disconnected
(
eenriquez.snf.stanford.edu
)
32:
Re: Problem rtagaas SNF 2006-07-26 19:45:24: thermocouple is broken
(
eenriquez.snf.stanford.edu
)
33:
Re: Problem rtagaas SNF 2006-07-20 15:59:59: negative temp display
(
eenriquez.snf.stanford.edu
)
34:
Problem rtagaas SNF 2006-08-15 08:08:05: New software
(
eenriquez.snf.stanford.edu
)
35:
Shutdown rtagaas SNF 2006-10-04 07:16:43: Using monitor and keyboard at STS
(
eenriquez.snf.stanford.edu
)
36:
Re: Shutdown rtagaas SNF 2006-10-04 07:16:43: Using monitor and keyboard at STS
(
eenriquez.snf.stanford.edu
)
37:
Shutdown rtagaas SNF 2006-10-23 14:27:53: Water leak
(
eenriquez.snf.stanford.edu
)
38:
Re: Shutdown rtagaas SNF 2006-10-23 14:27:53: Water leak
(
eenriquez.snf.stanford.edu
)
39:
Shutdown rtagaas SNF 2006-10-25 07:03:44: water leaks when door is opened
(
eenriquez.snf.stanford.edu
)
40:
Re: Shutdown rtagaas SNF 2006-10-25 07:03:44: water leaks when door is opened
(
eenriquez.snf.stanford.edu
)
41:
Shutdown rtagaas SNF 2006-10-26 10:52:48: Liquid under plastic
(
jperez.snf.stanford.edu
)
42:
Re: Shutdown rtagaas SNF 2006-10-26 10:52:48: Liquid under plastic
(
eenriquez.snf.stanford.edu
)
43:
Problem rtagaas SNF 2006-11-03 12:01:10:
(
mahnaz.snf.stanford.edu
)
44:
Problem rtagaas SNF 2006-11-03 12:04:12: temp on the front panel is 309
(
eunji.snf.stanford.edu
)
45:
Shutdown rtagaas SNF 2006-11-07 16:22:32: Lost piece found inside chamber
(
chion.snf.stanford.edu
)
46:
Re: Problem rtagaas SNF 2006-11-03 12:01:10:
(
eenriquez.snf.stanford.edu
)
47:
Re: Shutdown rtagaas SNF 2006-11-07 16:22:32: Lost piece found inside chamber
(
eenriquez.snf.stanford.edu
)
48:
Re: Problem rtagaas SNF 2006-11-03 12:04:12: temp on the front panel is 309
(
eenriquez.snf.stanford.edu
)
49:
Re: Problem rtagaas SNF 2006-08-15 08:08:05: New software
(
eenriquez.snf.stanford.edu
)
50:
Re: Problem rtagaas SNF 2006-04-10 11:41:47: Thermal couple reading problem
(
eenriquez.snf.stanford.edu
)
51:
Comment rtagaas SNF 2007-02-02 15:46:40: Low-Temp thermal couple is not installed
(
josephchen.snf.stanford.edu
)
52:
Problem rtagaas SNF 2007-02-28 21:00:13: temperature sensor problem
(
jennyhu.snf.stanford.edu
)
53:
Re: Problem rtagaas SNF 2007-02-28 21:00:13: temperature sensor problem
(
eenriquez.snf.stanford.edu
)
54:
Problem rtagaas SNF 2007-03-13 09:56:59: TC problem
(
jscyb.snf.stanford.edu
)
55:
Re: Problem rtagaas SNF 2007-03-13 09:56:59: TC problem
(
cbaxter.snf.stanford.edu
)
56:
Problem rtagaas SNF 2007-03-26 16:48:23: AC power off
(
jhpark9.snf.stanford.edu
)
57:
Comment rtagaas SNF 2007-03-27 07:16:09: Maintenance update
(
eenriquez.snf.stanford.edu
)
58:
Re: Comment rtagaas SNF 2007-03-27 07:16:09: Maintenance update
(
eenriquez.snf.stanford.edu
)
59:
Re: Problem rtagaas SNF 2007-03-26 16:48:23: AC power off
(
eenriquez.snf.stanford.edu
)
60:
Shutdown rtagaas SNF 2007-04-06 11:32:33: door or water error
(
griffin.snf.stanford.edu
)
61:
Re: Shutdown rtagaas SNF 2007-04-06 11:32:33: door or water error
(
eenriquez.snf.stanford.edu
)
62:
Problem rtagaas SNF 2007-04-19 13:36:17: lamp not turning on
(
nitigoel.snf.stanford.edu
)
63:
Shutdown rtagaas SNF 2007-04-21 22:53:46: Lamp doesn't turn on
(
jhpark9.snf.stanford.edu
)
64:
Re: Shutdown rtagaas SNF 2007-04-21 22:53:46: Lamp doesn't turn on
(
cbaxter.snf.stanford.edu
)
65:
Re: Problem rtagaas SNF 2007-04-19 13:36:17: lamp not turning on
(
cbaxter.snf.stanford.edu
)
66:
Problem rtagaas SNF 2007-04-23 22:55:02: Still doesn't work
(
jhpark9.snf.stanford.edu
)
67:
Shutdown rtagaas SNF 2007-04-24 08:40:40: Lamps does not turn on
(
eenriquez.snf.stanford.edu
)
68:
Comment rtagaas SNF 2007-04-24 13:07:24: Update
(
eenriquez.snf.stanford.edu
)
69:
Re: Shutdown rtagaas SNF 2007-04-24 08:40:40: Lamps does not turn on
(
eenriquez.snf.stanford.edu
)
70:
Re: Comment rtagaas SNF 2007-04-24 13:07:24: Update
(
eenriquez.snf.stanford.edu
)
71:
Re: Problem rtagaas SNF 2007-04-23 22:55:02: Still doesn't work
(
eenriquez.snf.stanford.edu
)
72:
Problem rtagaas SNF 2007-05-01 10:20:15: front panel display won't track T
(
griffin.snf.stanford.edu
)
73:
Comment rtagaas SNF 2007-05-03 09:07:50: LCD readout is not right
(
mtang.snf.stanford.edu
)
74:
Re: Problem rtagaas SNF 2007-05-01 10:20:15: front panel display won't track T
(
eenriquez.snf.stanford.edu
)
75:
Re: Comment rtagaas SNF 2007-05-03 09:07:50: LCD readout is not right
(
eenriquez.snf.stanford.edu
)
76:
Problem rtagaas SNF 2007-05-09 12:56:44: Temperature display lamp was off
(
donghun.choi.snf.stanford.edu
)
77:
Re: Problem rtagaas SNF 2007-05-09 12:56:44: Temperature display lamp was off
(
eenriquez.snf.stanford.edu
)
78:
Shutdown rtagaas SNF 2007-05-22 10:28:27: no power
(
griffin.snf.stanford.edu
)
79:
Re: Shutdown rtagaas SNF 2007-05-22 10:28:27: no power
(
griffin.snf.stanford.edu
)
80:
Problem rtagaas SNF 2007-05-24 21:00:53: Cooling Water & Thermocouple
(
jennyhu.snf.stanford.edu
)
81:
Comment rtagaas SNF 2007-05-25 17:51:41: cooling
(
raneeyoo.snf.stanford.edu
)
82:
Problem rtagaas SNF 2007-05-28 17:09:01: AC Power Problem
(
jennyhu.snf.stanford.edu
)
83:
Problem rtagaas SNF 2007-05-29 07:14:38: mouse mulfunction
(
masaharu.snf.stanford.edu
)
84:
Re: Problem rtagaas SNF 2007-05-28 17:09:01: AC Power Problem
(
eenriquez.snf.stanford.edu
)
85:
Re: Problem rtagaas SNF 2007-05-29 07:14:38: mouse mulfunction
(
eenriquez.snf.stanford.edu
)
86:
Re: Problem rtagaas SNF 2007-05-24 21:00:53: Cooling Water & Thermocouple
(
eenriquez.snf.stanford.edu
)
87:
Shutdown rtagaas SNF 2007-07-18 16:59:33: No AC power
(
slcheng.snf.stanford.edu
)
88:
Re: Shutdown rtagaas SNF 2007-07-18 16:59:33: No AC power
(
eenriquez.snf.stanford.edu
)
89:
Problem rtagaas SNF 2007-08-07 11:29:59: temp didnt ramp down to 150
(
zhangdw.snf.stanford.edu
)
90:
Shutdown rtagaas SNF 2007-08-13 09:07:58: Shutdown to investigate problem report
(
mtang.snf.stanford.edu
)
91:
Re: Shutdown rtagaas SNF 2007-08-13 09:07:58: Shutdown to investigate problem report
(
mtang.snf.stanford.edu
)
92:
Re: Problem rtagaas SNF 2007-08-07 11:29:59: temp didnt ramp down to 150
(
rissman.snf.stanford.edu
)
93:
Re: Comment rtagaas SNF 2007-05-25 17:51:41: cooling
(
rissman.snf.stanford.edu
)
94:
Shutdown rtagaas SNF 2007-08-20 17:51:10: Leakage of Water
(
slcheng.snf.stanford.edu
)
95:
Re: Shutdown rtagaas SNF 2007-08-20 17:51:10: Leakage of Water
(
cbaxter.snf.stanford.edu
)
96:
Problem rtagaas SNF 2007-09-03 14:58:46: Water leak! Do not use.
(
hpbae.snf.stanford.edu
)
97:
Shutdown rtagaas SNF 2007-09-03 15:07:36: Water leak..
(
hpbae.snf.stanford.edu
)
98:
Re: Shutdown rtagaas SNF 2007-09-03 15:07:36: Water leak..
(
cbaxter.snf.stanford.edu
)
99:
Re: Problem rtagaas SNF 2007-09-03 14:58:46: Water leak! Do not use.
(
cbaxter.snf.stanford.edu
)
[<<-]
[<-]
[->]
[->>]
|
[Threads by date]