Skip to content. | Skip to navigation

Sections
Personal tools
You are here: Home / Equipment

Equipment Summary

A listing of all SNF equipment, its current status and staff in charge.

Electron Beam Writers, Scanning Electron Microscopes, and Maskmaking

Name

Equipment

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super
Users

Training Hrs/
Notes

hummer

Hummer V Sputter Coater

Cont

Gary

Gary / Ted


1

raith

Raith 150 Electron Beam Lithography System

All

Mike Mleczko

TBA


12 (a)

sem4160

Hitachi 4160 Scanning Electron Microscope

All

TBA

Ted


3

 

Optical Photolithography: Resist Coat

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users

Training Hrs/
Notes

headway2

Headway Manual Resist Spinner

All

Mahnaz

Mario  / Gary


1 (a)

laurell-R / laurell3

Laurell Manual Resist Spinner

All

Mahnaz

Mario  / Gary


1 (a)

svgcoat / svgcoat2

SVG Resist Coat Tracks 1&2

All

Uli / Mahnaz

Gary  / Mario


1.25 (a)

evgspraycoat
EVG 101 Resist Spray Coater
All
Mahnaz

Gary  / Mario


1.5 (a)

 

Optical Photolithography: Exposure

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users

Training Hrs/
Notes

asml

ASML PAS 5500/60 i-line Stepper

All

1.Job Writing:
Mahnaz

2.Tool Training: Mahnaz

Gary  / Mario


Job Writing: 2

Tool Training: 2 (a)

evalign

EV Group Contact Aligner

All

Mahnaz

Mario  / Gary


1.5 (a)

karlsuss / karlsuss2

Karl Suss MA-6 Contact Aligner 1&2

All

Uli/ Mahnaz 

Gary  / Mario


1.5 (a)

 

Optical Photolithography: Develop

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users

Training Hrs/
Notes

svgdev / svgdev2

SVG Resist Develop tracks 1&2

All

Uli / Mahnaz

Gary  / Mario


0.5 (a)

 

Optical Photolithography: Ovens

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users

Training Hrs/
Notes

bluem

Blue M Programmable Oven

Cont

Mahnaz

Mario / Gary


0.5 (a)

oven110

110 C Oven

All

Uli

Mario / Gary


(a)

oven90

90 C Oven

All

Uli

Mario / Gary


(a)

oven3

Mahnaz's Oven

All

Mahnaz

Mario / Gary


0.5 (a)

ovensinge

Singe Oven

All

Uli

Mario / Gary


(a)

uvcure

Ultraviolet Photoresist Cure

All

Mahnaz

Mario / Gary


TBD (a)

yes

YES Prime Oven

All

Uli / Mahnaz

Mario / Gary


(a)

 

Chemical Vapor Deposition (CVD): Low Pressure

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users

Training Hrs/
Notes

teos2

teos2

Clean

Maurice

Ted / Ray


3 (b)

 thermcolto  Thermco LPCVD Low Temperature Oxide
Gold  Maurice  

Ted / Ray

   3 (b)

thermoconitride1

Thermo LPCVD Nitride

Clean

Maurice

Ted / Ray


(b)

thermocopoly1

Thermco LPCVD Poly

Clean

Maurice

Ted / Ray


(b)

thermocopoly2 Thermco LPCVD Poly  Gold Maurice  

Ted / Ray

   3 (b)

tylanbpsg

LPCVD BPSG

Clean/ Semiclean

Maurice

Ted / Ray


3 (b)

tylannitride

LPCVD Nitride

Clean

Maurice

Ted / Ray


4 (or 2 w/tylanpoly)  (b)

tylansige

LPCVD silicon Germanium Poly

Clean

Maurice

Ted / Ray


6 (b)

cvd-nanotube First Nano carbon nanotube CVD furnace  Gold  TBA
 Ted / Ray  Greg Pitner  3
aixtron-graphene Aixtron Black Magic graphene CVD furnace  Gold  TBA
 Ted / Ray Chris Neumann, Yong Cheol Shin, Ning Wang  3

 

Chemical Vapor Deposition (CVD): Plasma Enhanced

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users

Training Hrs/
Notes

sts

STS Plasma Enhanced CVD

Cont

Usha

Jim


2 X 1.25

tel

TEL Trias SPA Plasma Processing System

Clean

Peter

Ted


N/A

 hdpcvd PlasmaTherm Versaline HDP VCD System
All  Usha/
Jim M
 

Elmer / Mike

   1.0
 ccp PlasmaTherm Shuttlecock PECVD System
 All  Usha/
Jim M
 

Elmer / Mike

   1.0

 

Chemical Vapor Deposition (CVD):  Atomic Layer

Name

Equipment Name

Materials/
Equip Group

Process

Maintenance/
Repair

Super Users

Training Hrs/
Notes

savannah Savannah Atomic Layer Deposition System Gold Michelle 
Jim J Provine
3.0
See equipment page
 fiji1/fiji2  Fiji Atomic Layer Deposition - semi-clean chamber and gold chamber
 Semi-Clean (Fiji1)
Gold (Fiji2)
Michelle  Jim J Provine
3.0
see equipment page
fiji3
Fiji Atomic Layer Deposition- gold chamber, dielectric dedicated
Gold Michelle Jim J Provine covered in fiji1/2
mvd
Savannah/Plasma Cleaner in Glovebox System
Gold Michelle Jim J Provine 3.0

 

Chemical Vapor Deposition (CVD):  Epitaxial

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users

Training Hrs/
Notes

epi2

Applied Materials Centurion Epitaxial System

Clean

 Maurice

Elmer / Mike


2x2

aix200 Aixtron MOCVD - III-V system Cont  Xiaoqing  Ted / Ray/ Jim  Antony Jan 2x2+final
aix-ccs Aixtron MOCVD - III-N system Cont  Xiaoqing  Ted / Ray/ Jim  Hongyun So 2x2+final

Metallization and Sputtering

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users
Training Hrs/
Notes

innotec

Innotec ES26C E-Gun Evaporator

Cont

Maurice

Jim


2 X 3

metalica

Metallica Sputter System

Cont

Xiaoqing

Jim

Ludwig Galambos

2 X 3hr

intlvac_sputter
IntlVac Nanochrome I Sputter System

Clean/ Semiclean

Maurice

Jim


 2 x 1

intlvac_evap IntlVac Nanochrome I Evaporator System

Clean/ Semiclean

Mahnaz Jim    2

 lesker-sputter  Exfab 155:
Lesker Sputter

 Cont  Maurice  Carsen    1
 aja-evap  Exfab 155:
AJA Evaporator

 Cont  Sage Doshay
 Carsen    TBD

 

Dry Etching

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users
Training Hrs/
Notes

amtetcher

AMT Oxide Plasma Etcher

Clean / Semiclean

Usha

Elmer / Mike


1

drytek2

Drytek 100 Plasma Etcher

All

 
Usha

Elmer / Mike


1 (c)

drytek4

Drytek 100 Plasma Etcher

Cont

Usha

Elmer / Mike


1 (c)

gasonics

Gasonics Aura Asher

Clean / Semiclean

see equipment page

Elmer / Mike


 

lampoly

Lam Research TCP 9400 Poly Etcher

Clean

Usha

Elmer / Mike


1

matrix

Matrix Plasma Resist Strip

Cont

Usha

/ Uli

Elmer / Mike


0.5

mrc

MRC Reactive Ion Etcher

Cont

Usha

Elmer / Mike


1.5

p5000etch

Applied Materials P5000 Etcher

Semiclean

Usha

Elmer / Mike


1.5

 PT-DSE  Plasma Therm Versaline LL ICP Deep Silicon Etcher
 Cont  Usha
 

Elmer / Mike

   1.5
 PT-MTL  Plasma Therm Versaline LL ICP Metal Etcher
 Cont  Usha  

Elmer / Mike

   1
 PT-Ox  Plasma Therm Versaline LL ICP Dielectric Etcher
 Cont  Usha  

Elmer / Mike

   1

pquest

Plasma Quest ECR Etcher

Cont

Usha

Elmer / Mike


1

 Ox-35  Oxford III-V etcher
 Cont  see equipment page  

Elmer / Mike

   1.5

stsetch

STS Deep RIE Etcher

Clean

Usha

Elmer / Mike


2

 uetch  SPTS uetch vapor etch
 All  Uli Jim  / Mike    0.5

xactix

Xactix Xenon Difluoride Etcher

Clean / Semiclean /Cont

Uli

Elmer / Mike


0.5

 

Annealing, Oxidation, and Doping

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users
Training Hrs/
Notes

thermco1-3

Thermco Oxidation Furnace

Clean

Maurice

Ted / Ray


1 (b)

thermco4

Thermco Oxidation Furnace

Cont

Maurice

Ted / Ray


3 (b)

tylan9

Forming gas Anneal Furnace

Cont

Maurice

Ted / Ray

tylan6

Phos Predep Furnace (POCl3)

Clean

 Maurice

Ted / Ray


(b)(d)

tylanfga

Forming gas Anneal Furnace

Semiclean

 Maurice

Ted / Ray


3 (b)(d)

 

Rapid Thermal Annealing

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users
Training Hrs/
Notes

aw610-l

AllWin 610 Rapid Thermal Annealer

Clean/Semi-clean
Maurice

Elmer / Mike


1

aw610-r

AllWin 610 Rapid Thermal Annealer

Cont

Maurice

Elmer / Mike


1

 

Wetbenches

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users

Training Hrs/
Notes

cpd

Critical Point Dryer

Cont

Uli / Maurice

Jim / Mike


2

lithosolv

Lithography Solvent Bench

All

Uli / Mahnaz

Mario


(a)


Mask Scrubber

N/A

Mahnaz

Mario



wbclean-1 and 2 (former wbdiff)

Clean-1 and 2 Wetbench

Clean

Uli

Jim / Gary


2.25

wbebeam

Ebeam Process Wetbench

All

TBA

Gary  / Mario

 


NA

wbflexcorr-1 and-2 (former wbgaas)

Flexible Corrosive Wetbench and GaAs

All and GaAs

Uli / Mary

Jim / Gary


2.25

wbflexcorr-3 and 4 (former wbgen)

Flexible Corrosive Wetbench

All (no GaAs)

Uli / Mary

Jim / Gary


2.25

wbgen2-hp / wbgen2-rfx

Germanium wbgen-2

Clean Ge

Mary

Jim / Gary

Ju-Hyung

wbclean-1 and 2 required

wbmetal

Metal Wetbench

Semiclean

Uli

Jim / Gary


.75

wbmiscres

Miscellaneous Photoresist Wetbench

All

Mahnaz / Uli

Mario / Gary


(a)

wbnitride

Nitride and Tweezer Cleaning Wetbench

Clean

Uli

Jim  /Gary


.75

wbnonmetal

Non-Metal Wetbench

Clean

Uli

Jim / Gary


covered in wbclean-1 and2

wbdecon/clean-3 (former wbsilicide)

Decon and Clean-3 Wetbench

Clean

Uli 

Jim / Gary


wbclean-1 and 2 required

wbsolvent

Solvent Wetbench

All

Uli / Mary

Jim / Gary  / Mario

 


.5

 

Wafer Bonding, Sawing, and Polishing

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users
Training Hrs/
Notes

cmp

GnP Poli-400L

 Hardware for both contaminated and clean

Michelle

Jim H.

Gary Yama

 1.5

 evbond  EV Group Wafer Bonder  Cont  

Mahnaz/Mary

 

Mario / Gary

   4

ksbonder

Karl Suss Wafer Bonder

Clean

Mahnaz

Mario / Gary


1

 DISCO wafersaw DISCO Wafer Saw
Cont  Usha/ Mary  Elmer/ Gary/ Ted    1.5

 

Characterization and Testing

Name

Equipment Name

Materials/
Equip Group

Process/
Training

Maintenance/
Repair

Super Users
Training Hrs/
Notes

afm2

Digital Instruments Nanoscope 3000 AFM

All

TBA

 

Mario / Gary


3

alphastep

Alphastep 500 Profilometer

Cont

Uli

Mario / Gary


.25

nanospec / nanospec2

Nanospec Film Thickness Measurement System

All

Uli

Gary / Mario


.25

prometrix

Prometrix Resistivity Mapping System

All

Uli / Maurice

Gary / Mario

 


.5

p2

Tencor P2 Profilometer

Semiclean/
Clean

Uli

Gary / Mario


.5

 s-neox Sensofar S-neox, non contact 3D optical profiling
 All  Uli  

Gary / Mario

   1

stresstest

Flexus 2320

All

Uli

Gary


.75

woollam

J.A. Woollam M2000 Spectroscopic Ellipsometer

All

Michelle

Gary


2

Document Actions