Effect of Isochronal Hydrogen Annealing on Surface Roughness and Threading Dislocation Density of Epitaxial Ge on Si

Shin-ichi Kobayashi, Y. Nishi and K. C. Saraswat-- We report the effect of hydrogen annealing on the surface roughness and threading dislocation density (TDD) of germanium (Ge) films grown on silicon (Si) substrates by reduced-pressure chemical vapor deposition (RPCVD). The surface roughness initially decreased with an increase in the annealing temperature. At annealing temperatures greater than 650 °C the film thickness varied owing to surface undulations, leading to an increase in the surface roughness. Although high-temperature annealing at 850 °C is effective for reducing TDD, the surface roughness of a 150-nm-thick Ge film annealed at 650 °C reaches a minimum value (~0.7 nm).

Document Actions