Skip to content. | Skip to navigation

Sections
Personal tools
You are here: Home / Equipment / Dry Etching / Table and Overview of available etchers at SNF

Table and Overview of available etchers at SNF

This chart gives a quick reference to the available plasma etchers at SNF and SNSF.

 

Etcher Primary 
Materials
Etched
Other
Materials 
Etched
Available 
Gases
Etcher 
Type
Wafer
Size
Maximum 
Load
Size
Other Factors/
Considerations/
Comments
P5000etch
Chamber A
Al, Al/Si Ti, TiN Ar, BCl3, CF4,
Cl2, N2, SF6
Magnetically
Enhanced
RIE - MERIE
4" 8 per loadlock
pumpdown,
50 max
Single wafer etch chamber;
Same load lock & cassette elevator for all three chambers;
pieces need to be mounted on a carrier wafer for etching
P5000etch
Chamber B
SiO2, SiN Si, SiC,
carbon,
polyimide
CHF3,CF4, Ar,
He, O2 N2
Magnetically
Enhanced
RIE - MERIE
4" 8 per loadlock 
pumpdown, 
50 max
Single wafer etch chamber; 
Same load lock & cassette elevator for all three chambers; 
pieces need to be mounted on a carrier wafer for etching
P5000etch
Chamber C
Poly Si, Si W silicide,
W, SiGe, Ge
Cl2, HBr, NF3, CF4,
SF6, He/O2
Magnetically
Enhanced
RIE - MERIE
4" 8 per loadlock 
pumpdown, 
50 max
Single wafer etch chamber; 
Same load lock & cassette elevator for all three chambers; 
pieces need to be mounted on a carrier wafer for etching
AMTEtcher SiO2, SiN,
Si, PR
SiC, SiON,
carbon,
polyimide
O2, CHF3, SF6,
Ar, NF3
RIE 4" 24 Batch processing tool with hexode configuration;
pieces need to be mounted on a carrier wafer for etching
 Drytek 2 PolySi, Si,
SiN, PR
SiO2,
carbon,
polyimide
 O2, CF4, SF6,
CHClF2
ccp -
parallel plate-
Plasma mode
2-6",
pieces
 6  Batch processing tool; 6 stacked electrodes; no clamp; wafers
and pieces can be loaded directly on the grounded electrode
 Drytek 4 SiO2, Si, SiN,
PR, organics
   O2, N2, Ar, SF6,
CHF3, C2F6
 RIE  2-6", 
pieces
 1 Single wafer etch; no clamp; pieces can be loaded directly
onto the electrode.
 Gasonics Photoresist
Strip
   O2 Downstream
Plasma
 4"  25  Single wafer tool with auto loading from a cassette.  Pieces need
a pocket carrier wafer for transport. Wafers heated by lamps.
Matrix  Photoresist
Strip
   O2 Downstream
Plasma
 4"  25 Single wafer tool with auto loading from a cassette. 
Pieces need a pocket carrier wafer for transport.
Chuck temperature controls wafer heating.
 Lampoly  Poly Si, Si SiO2, SiN, PR,
Ge, SiGe 
O2, N2, H2, Cl2,
HBr, CF4, C2F6
 ICP (TCP)  4" 25  Single wafer etch with auto-loading from a cassette.
Equipment originally used for gate etching with high selectivity
to thin gate oxides. 
 MRC Metals, 
Dielectrics
Metal oxide,
polyimide
 O2, Ar, SF6,
CHF3, CHClF2
 RIE 2-6", 
pieces 
 1 Typically used for sputter etching; Single wafer, direct load system; 
wafers/ pieces can be directly placed on electrode
 PT-DSE  Si Isotropic
Si etching
C4F8, SF6,
Ar, O2
 ICP 4" or
6"
 1 Single wafer; Bosch process for Si etching; Default 4" config; Can be
converted to 6" config; pieces need to be attached to carrier wafer;
need a support wafer for through wafer etching
 PT-MTL Various
metals
Metal oxides Cl2, BCl3, O2,
SF6, Ar, CF4,
CH4, N2
 ICP 4" or
6"
 1 Single wafer; Default 4" config; Can be converted to 6" config; pieces need
to be attached to carrier wafer; Restrictions:  Can not etch metals or
metal oxides with no volatile by-products (shorting & arcing issues)
 PT-OX SiO2, SiN,
SiC,
diamond
 
Other carbon
and Si
based materials
C4F8, H2, Ar, CF4,
O2, CHF3, He, N2
 ICP 4" or
6"
 1 Single wafer; Default 4" config; Can be converted to 6" config; pieces need 
to be attached to carrier wafer; Restrictions:  Can not etch metals or 
metal oxides with no volatile by-products (shorting & arcing issues)
PQuest III-V
materials
Varied Ar, SF6, N2, H2,
O2, CF4, He, BCl3,
Cl2, SiH4*, CH4*
 ECR 4"  1 Single wafer; 4" config only; Pieces need to be attached to carrier wafer.
* - SiH4 and CH4 are plumbed, but not hooked up
 OX-35 GaAs, Varied  III-V materials
such as GaN, InGaP, 
AlGaN etc
BCl3, Cl2, HBr, CH4,
H2, Ar, O2, N2, SF6
 ICP 4" 1 4" wafers; can be adopted to do 6" or 8" wafers; pieces need to be bonded
to carrier wafers; Restrictions:  III-V materials only. 
 Oxford-rie SiO2, SiN, SiC,
polyimide
Diamond etc CF4, CHF3, O2, Ar RIE 4"  1 4" wafers; can be adopted to do 6" or 8" wafers; pieces need to be bonded 
to carrier wafers; Restrictions:  III-V materials only. 
 stsetch Si SiGe, Ge SF6, C4F8, O2  ICP 4" 1 4" wafers; pieces should be attached to the carrier wafer for etching;
need to use the holder assembly for through wafer etching
 stsetch2 Si  SiGe, Ge  SF6, C4F8, O2  ICP 4" 1 Default 4"; can be configured to etch 6";
better for SOI etching relative to stsetch
 uetch SiO2 -
Isotropic
Varied HF vapor and
ethanol
Vapor
Etching
Pieces
to 8"
1 Pieces need a carrier wafer
 Xactix Si, Ge, SiGe-
Isotropic
  XeF2, N2 Vapor
Etching
Pieces
to 6" 
Isotropic Si etching; can be used for backside Si removal on small pieces
Plasmaetch
PE-50
 Phoresist  Surface
treatment
 Air  RIE  Pieces
to 6"
 Multiple Low power, high pressure plasma; low bias, minimal damage.
At SNF - nSiL lab
Ion Mill
(at SNSF)
 Varied    Ar Ion Milling Pieces
to 4" 
 1 Ion Mill is useful for removing materials with non-volatile by products
by sputter etching;
Location: SNSF; Spilker Building - Flexible cleanroom
RIE: Oxford
PlasmaPro 80

(at SNSF)
 SiO2, Si, SiN PR, polyimide,
Ti, TiN, W,
carbon, etc
CF4, CHF3, Ar, 
O2, SF6
 RIE Pieces
to 8"
 1  No carrier wafer needed; multiple pieces can be processed together
Location: SNSF; Spilker Building - Nanopatterning cleanroom

 

 
 

Overview of Available Etchers

The following is a detailed overview of all the etchers at SNF. This list is courtesy of Jim McVittie.  Refer to the equipment Summary page for contamination classification.

 

MRC- Simple manual load RIE (parallel plate with power to wafer electrode) without load lock 
and without He back side cooling.

 ·         It is for non-critical etching using oxygen and F chemistry only.

 ·         No endpoint detection.

 ·         Pressure: 5 to 100 mT using diffusion pump.

·         This is considered a low plasma density tool.

 ·         General purpose tool open to all materials with no toxic products.

 ·         Gases: O2, Ar, SF6 and CHF3

 

 P5000- 3 chamber auto load locked MERIE (magnetically enhance RIE) etcher with clamping and He 
backside cooling. The chambers are dedicated to;

 ·         A - Metals  -- Mainly uses for Al. Great for TiN. Has Ar, Cl2, BCl3, N2, CF4 and SF6

 ·         B - Oxide -- Mainly used for SiO2 and Si2N3 etching. Has Ar, CF4, CHF3, N2 and O2

 ·         C - Si -- Mainly used for Poly Si and Si trench etching.  Has Ar, Cl2, HBr, NF3, SF6 
and He/O2

Each chamber has its own OES spectrometer for endpoint.

 

 Although we do breakthrough steps at 30 mT for increased ion energy, the tool has small turbo 
pumps so most for the processes are done higher pressures, typically in the 200 mT range.  The 
rotated magnetic field yields higher plasma densities (higher rates), lower bias voltage for a 
given power and more ion directionality for a given pressure than RIE.  The tool can be operated 
as a pure RIE tool by turning off the magnetic field. This tool is considered a medium plasma 
density tool because of the effect of the magnetic field. This is the workhorse etcher for the 
standard Si processing. While lower pressure tools, such as the Lam TCP/ICP, can achieve smaller 
line widths, the P5000 meets most of small CMOS needs.

 

 Pquest- Load locked ECR (magnetic field used to couple microwave power to plasma) etcher dedicated mainly to III-V etching with other materials allows on limit basis.

 ·         It uses a mechanical clamp with He.

 ·         It has a separate rf bias supply to control ion energy.

 ·         Like the STS2, it uses multipole magnetic confinement around the outside of the 
chamber, to minimize plasma wall loss between the ECR zone and the wafer.

 ·         Gases include: Ar, Cl2, BCL3, N2, H2, O2, CF4 and SF6.

 ·         The III-V users are concerned about F and Cl interaction so they divide the tool time 
between F only and Cl only periods and require a wet clean after the F use period.

 

Lam Poly- ICP (inductive coupled plasma) etcher with a load lock, mechanical clamp and He 
cooling. For marketing purposing the flat ICP coil design is referred to as TCP (transform 
coupled plasma) although all ICPs can be describes as TCPs. 

 ·         Has large turbo pump so it can work at low pressures where the mean free path lengths 
are longer so one gets more directional ions, which means it can etch smaller line widths.

 ·         Because the inductive coupling allows high plasma density at low plasma potentials, 
a second rf supply can be used with capacitive coupling to control the sheath voltage at the 
wafer to control ion energy and directionality at the wafer surface.

 ·         The Lam is mainly used for poly-Si and Si etching.

 ·         It has very good line width resolution.

 ·         Its gases include: Cl2, HBr, C2F6, Cf4, SF6, O2, N2 and He/O2.

 ·         The SF6/O2 process tends to have grass (micro-masking) because Al2O3/Al sputtering 
from the clamp. SF6/Cl2 gets around the grass problem because the Cl removes the Al.

 ·         It has narrow band optical filters for OES endpoint.

 

STS1- First generation switched Bosch process (repeated cycle of separate deposition and etch 
steps) deep Si etcher.

 ·         600w ICP tool with mechanical clamp, He cooling and wafer bias (13.56MHz).

 ·         Does not have pulsed low frequency biasing for eliminating notching with SOI wafers.

 ·         This tool is still the workhorse for deep Si etching in the lab.

 ·         Gases: Ar, SF6, C4F8 and O2. It has no endpoint monitoring.

 

 STS2- 2nd generation switched Bosch process deep Si etcher. 3000w ICP tool with mechanical clamp, He cooling and wafer bias (13.56MHz).

 ·         It has both high frequency (13.56MHZ) and low frequency (350KHz) bias power. The low 
frequency can be pulsed for eliminating notching in SOI wafers.

 ·         It also has heaters to minimize polymer deposition on the walls and ICP ceramic.

 ·         Has suffered from poor ICP RF power matching during switched process. Labmembers must consult with responsible staff member before running a new recipe.

 ·         Tool gives good results for users who spend the time to tune the process for their needs.

 ·         Currently, there is lots time available on this tool.

 ·         It is presently a "clean" tool so it is restricted to clean materials. We have both 4" and 6" wafer chucks for this tool.

 ·         The chuck temperature can be controlled from 40 to -20C although the actual wafer temperature is 100C or higher for typical ICP powers.

 ·         Gases: Ar, SF6, C4F8 and O2. It has no endpoint monitoring.

 

PT-DSE- 3rd generation switched Bosch process deep Si etcher.  3000w ICP tool with mechanical clamp, He cooling and wafer bias (100KHz). This tool is made by PlasmaTherm (PT)

 ·         To get fast stable switching it has ALD style gas switching, ICP frequency tuning 
during the switched process and an improved pressure switching algorithm.

 ·         In addition, the bias power has pulse modulation for processing SOI wafers.

 ·         Like STS2, it has a complement of heaters to minimize chamber deposition. This is a newer tool in comparison to STS2 whose initial etch results look great.

 ·         Gases: Ar, SF6, C4F8 and O2.

 ·         The chuck temperature can be controlled from 40 to -40C although we have not tested 
the actual wafer temperature during an etch process.

 

 PT-Metal- New ICP etcher dedicated for etching metals and process related material.

 ·         It has a large turbo pump so it can be operate down a few mT.

 ·         The ICP has a 2500w generator (2MHz) with a 600w bias generator (13.56MHz).

 ·         Like our other PT etchers, it has wall and ICP heaters to minimize chamber deposition.

 ·         The wafer chuck has a mechanical clamp with He cooling and has temperature is control 
from 10 to 60C. 

 ·         Like STS2, we have both 4" and 6" wafer chucks for this tool.

 ·         Initially, it has Al and Ti/W etch processes. Al process should be great for TiN etching.  It has a Cr process still to be tested.

 ·         Gases: Cl2, BCl3, SF6, O2, N2, Ar, CF4, and CH4.

 ·         For endpoint control it has an Ocean Optic spectrometer for OES and a laser for interferometry.

 

PT-Dielectric- New ICP etcher dedicated for etching dielectrics and process related material.

 ·         It has a large turbo pump so it can operate down a few mT.

 ·         The ICP has a 3500w generator (2MHz) with a 600w bias generator (13.56MHz).

 ·         Like our other PT etchers, it has a wall and ICP heaters to minimize chamber deposition.

 ·         The chuck has a mechanical with He cooling and temperature control from 40 to -40C.

 ·         It is typically used for Si based dielectric etching (Silicon dioxide, Silicon nitride etc).

 ·        Gases: C4F8, CF4, CHF3, Ar, He, H2, N2 and O2 – Note:  H2 and O2 should not be sued in the same process.

 ·         It has an Ocean Optic spectrum for OES endpoint in addition to laser interferometry.

 

Oxford III-V- New ICP etcher dedicated for etching III-V materials. Like the other ICP tools, 
it has a load lock, a mechanical clamp and He backside cooling.

 ·         Has processes for GaAs, GaAlAs, GaP, InP and GaN.

 ·         InP can be etched hot (170C) using Cl2 based process and room temperature using a 
CH4/H2 process. Sample heating can be done either by heating the chuck or by plasma heating.

 ·         Has laser interferometry for endpoint.

 ·         The large turbo pump allows processing down to 2 mT.

 ·         Gases include: BCl3, SF6, Cl2, HBr, H2, Ar, N2, and CH4.

 ·         There are heaters for heaters for the chamber and ICP source to minimize deposition.

 

AMT Etcher- This an old Applied Material 8110 Hexode (SS bell jar with center electrode) for 
batch RIE processing.

 ·         It is a “clean” tool dedicated to oxide and nitride etching which has etch rate about 10X less that the P5000 but a bit better selectivity but can 20 wafers at a time. It also does great anisotropic (low selectivity and low rate) Si etching using NF3.

 ·         It has a medium sized turbo pump so it works well down to 20 mT.

 ·         It has laser interferometry which is currently not used.

 ·         Its gases are Ar, N2, CHF3, O2, SF6 and NF3.

 

Drytek2- Plasma mode (wafers on ground electrode) non-load lock and unclamped for F bases 
etching of poly-Si, Si, nitride and related materials.

 ·         Also used for descuming resist and removal of plasma damage such as after oxide 
etching in AMT etcher.

 ·         Has laser interferometry which is not currently used. It has 6 electrodes (4 for 
clean work) for batch processing.

 ·         It uses a wet mechanical pump and blower so it is limited to pressures above 100 mT.

 ·         It was purchased in 1981.

 ·         Its poly etch (SF6/F22) process is semi-anistropic with a 0.1 um undercut.

 ·         Its isotropic Si/Poly etch (CF4/O2 at 700 mT) is extremely isotropic (same etch 
rate everywhere in a structure).

 ·         Gases: CF4, SF6, F22 (CHClF2) and O2   

 

 Drytek4- RIE mode non-load lock and unclamped for F bases etching.

 ·         This tool is an open tool mainly used by III-V users for nitride mask etching. The 
III-V user will probably mover to one of the new PT tools.

 ·         Like the other Drytek it has a mechanical pump but because of its small chamber, it 
is operated below 100 mT.

 ·         Gases: Ar, SF6, CHF3, and O2.

 

Matrix- Downstream plasma tool for O2 plasma resist stripping for general use.

 ·         This is a single wafer tool with auto load from a 25 wafer cassette

 ·         Downstream means that there are baffles between the wafer and the rf generated plasma 
so reactive Ox radicals can make it to the wafer but not the plasma. This eliminates plasma 
damage to sensitive surfaces.

 ·         It has programmable lift pins, which allow the wafer to be either room temperature 
(pins up) or hot (pins down) with the wafer in contact with a 180C heated stage.

 ·         Resist stripping is strong temperature activated.  With the pins down the strip 
rate > 1 um/min, but with pins up the rate is a few hundred A/min.

 ·         While a plasma stripper can remove organic polymers, such as resist, it does remove 
metals which will often remain on the surface as a metal oxide. This is why one usually needs 
to do a wet clean after a plasma strip. A descum process can be done at lower power and pressure.

·         It only has one gas, O2.

 

Gasonics- Downstream plasma tool for O2 plasma resist stripping for “clean” wafers.

 ·         This is a single wafer tool with auto load from a 25 wafer cassette

 ·         Like the Matrix, there are baffles between the wafer and the plasma but this tool 
uses microwave power to generate the plasma.

 ·         This system uses lamps for the heating. The caution with using lamp heating is that 
the heating depends on what is on the wafer surface. Oxide, metal poly-Si and implantation can 
all affect the wafer temperature and thus the strip rate.

 ·         Gases: N2 and O2

Document Actions