1. PRODUCT AND COMPANY IDENTIFICATION

 

 MICROPOSIT(TM) MF(TM) -322 Developer

 

Revision date:

01/01/2004

 

Supplier Name & Address

Supplier

 

Rohm and Haas Electronic Materials LLC

455 Forest Street

Marlborough, MA  01752  United States of America

 

Manufacturer Name & Address �Canada only

 

Telephone

 

For non-emergency information contact:  508-481-7950

 

 

Emergency Telephone

Emergency telephone number

 

Chemtrec

800-424-9300

 

Rohm and Haas Emergency

215-592-3000

 

 

 

2. COMPOSITION/INFORMATION ON INGREDIENTS

SECTION 2.  Composition / information on components

Component

CAS CAS-No.

W/W Concentration

 

 

Water

7732-18-5

> 95.0 %

Tetramethylammonium hydroxide

75-59-2

2.4%

Surfactant

 

< 1.0 %

 

Canadian composition

 

 

EU & APR Composition

 

3. HAZARDS IDENTIFICATION

Section 3 Hazards Identification

Emergency Overview

 

Emergency Overview

Form

Appearance

Form

liquid 

Color

Colour

colourless 

Odor

Odour

amines   

 

Hazard Summary

Warning!

Alkaline liquid and vapor. Causes skin, eye, and respiratory tract irritation. Onset of symptoms may be delayed.

Prolonged, repeated contact, inhalation, ingestion, or absorption through the skin, may cause toxic effects to internal organ systems (liver, kidney, central nervous system).

 

 

 

 Potential Health Effects

 

Potential Health Effects

Primary Routes of Entry

 Primary Routes of Entry:

Inhalation, ingestion, eye and skin contact, absorption.

 

Eyes

Eyes: May cause pain, transient irritation and superficial corneal effects.

 

Skin

Skin: Material may cause irritation.

Prolonged or repeated exposure may have the following effects:

central nervous system depression

drowsiness

defatting of skin leading to irritation and dermatitis

 

Ingestion

Ingestion: Swallowing may have the following effects:

irritation of mouth, throat and digestive tract

Repeated doses may have the following effects:

central nervous system depression

drowsiness

 

Inhalation

Inhalation: Inhalation may have the following effects:

irritation of nose, throat and respiratory tract

Higher concentrations may have the following effects:

systemic effects similar to those resulting from ingestion

 

Target Organs

Target Organs: Eye

Respiratory System

Skin

nervous system

 

 

Environmental effects

Carcinogenicity �US & Shipley/Rodel

 

Carcinogenicity

Not considered carcinogenic by NTP, IARC, and OSHA

Japan FCIA

 

4. FIRST AID MEASURES

Section 4 First Aid Measures

Inhalation

Inhalation: Remove from exposure.  If there is difficulty in breathing, give oxygen.  Seek medical attention if symptoms persist. 

 

 

Skin contact

Skin contact: Wash skin with water.  Continue washing for at least 15 minutes.  Obtain medical attention if blistering occurs or redness persists. 

 

 

Eye contact

Eye contact: Immediately flush the eye with plenty of water for at least 15 minutes, holding the eye open.  Obtain medical attention if soreness or redness persists. 

 

 

Ingestion

Ingestion: Wash out mouth with water.  Have victim drink 1-3 glasses of water to dilute stomach contents.  Immediate medical attention is required  Never administer anything by mouth if a victim is losing conciousness, is unconcious or is convulsing. 

Notes to physician

Notes to physician -- treatment

Treat symptomatically. 

5. FIRE-FIGHTING MEASURES

Section 5 Fire Fighting Measures

Flash Point

Flash point

Nonflammable

 

Auto Ignition Temperature

Lower Explosive Limit

Upper Explosive Limit

 

Minimum ignition energy of dust cloud �indicate cloud vs layer

Thermal Decomposition

Suitable extinguishing media

 

Suitable extinguishing media:

Not readily combustible.

Select extinguishing agent appropriate to other materials involved.

 

Unsuitable extinguishing media

Specific hazards during fire fighting

 

Specific hazards during fire fighting: No specific measures necessary. 

Special protective equipment for fire fighters

 

Special protective equipment for fire-fighters: Wear full protective clothing and self-contained breathing apparatus. 

Further information

 

Further information: This product may give rise to hazardous vapors in a fire.

Other fire safety data

 

 

6. ACCIDENTAL RELEASE MEASURES

Section 6 Accidental Release Measures

Personal precautions

Personal precautions

Wear suitable protective clothing.

 

Environmental precautions

Environmental precautions

Prevent the material from entering drains or water courses.

Do not discharge directly to a water source.

Advise Authorities if spillage has entered watercourse or sewer or has contaminated soil or vegetation.

 

Methods for cleaning up

Methods for cleaning up

Cover with absorbent or contain.  Collect and dispose.

 

 

Additional advice

Possibly add reference to Sec 15

 

7. Handling and storage

Section 7 Handling and Storage

Handling

Handling

Use only in well-ventilated areas.  Avoid breathing vapor.  Avoid contact with eyes, skin and clothing.  Keep container tightly closed. 

Further information on storage conditions

Further information on storage conditions: No special precautions necessary. 

Advice on protection against fire and explosion

 

Storage

Storage

Storage conditions: Store in original container.  Storage area should be:  cool  dry  well ventilated  out of direct sunlight  away from incompatible materials 

Storage period

Storage temperature

 

 

Other data

Other handling and storage

 

 

8. EXPOSURE CONTROLS / PERSONAL PROTECTION

Section 8 Exposure Controls/Personal Protection

Exposure guidelines

Exposure limit(s)

 

Exposure limits are listed below, if they exist.

 

 

 

 

 

 

Eye Protection

 

Eye protection: goggles 

Hand Protection

 

Hand protection: Butyl rubber gloves. Other chemical resistant gloves may be recommended by your safety professional. 

Skin & Body Protection

 

Skin and body protection: Normal work wear. 

Respiratory Protection

 

Respiratory protection: Respiratory protection if there is a risk of exposure to high vapor concentrations.  The specific respirator selected must be based on the airborne concentration found in the workplace and must not exceed the working limits of the respirator. 

Hygienic Practices

General Protective Measures

Engineering Controls

 

Engineering measures: Engineering methods to prevent or control exposure are preferred.  Methods include process or personnel enclosure, mechanical ventilation (local exhaust), and control of process conditions. 

 

 

9. PHYSICAL AND CHEMICAL PROPERTIES

Section 9 Physical and Chemical Properties

Appearance

Form

Form

liquid 

Color

Colour

colourless 

Odor

Odour

amines   

 

pH

pH

12

Boiling Point

Boiling point/range

> 100 �C  (> 212 �F)

Freezing Point

Flash Point

Flash point

Nonflammable

 

Auto Ignition Temperature

Lower Explosive Limit - Dust

Upper Explosive Limit - Dust

Lower Explosive Limit

Upper Explosive Limit

Vapor Pressure

Vapour pressure

 Similar to water

 

Component: Tetramethylammonium hydroxide

Vapour pressure

17.5 mmHg at 20 �C  

 

Relative Vapor Density

Relative vapour density

no data available

Solubility in Water

Water solubility

completely soluble

Solubility (quantitative)

Solubility (qualitative)

Partitioning Coefficient

Relative density (Specific Gravity)

Relative density

1.05

Density

Bulk Density

Viscosity (Dynamic)

Flow time

Viscosity (Kinematic)

Evaporation rate

Evaporation rate

Slower than ether

 

Surface Tension

% Volatility

VOC

VOC's

not applicable

General Remarks

Disclaimer

 

NOTE:  The physical data presented above are typical values and should not be construed as a specification.

 

10. STABILITY AND REACTIVITY

Section 10 Stability and Reactivity

Hazardous reactions

Hazardous reactions

Stable under normal conditions.

 

 

Conditions to avoid

Conditions to avoid

 contact with incompatible materials 

 

Materials to avoid (InCompatibility)

Materials to avoid

Oxidizers  Acids. 

 

Hazardous Decomp prods

Hazardous decomposition products

Methanol, triethylamine, nitrogen oxides (NOx), oxides of carbon,

Polymerization

polymerization

Will not occur.

 

 

11. TOXICOLOGICAL INFORMATION

Toxicological information on this product or its components appear in this section when such data is available.

 

 

Section 11 Toxicological Information

Acute Oral Tox

Acute Inhalation tox

Acute Dermal tox

Acute tox other route

Skin irritation

Eye irritation

Sensitization

Respiratory system irritation

Chronic/sub-chronic tox

Carcinogenicity

Assessment Carcinogenicity

Toxicity to reproduction

Assessment Toxicity to Reproduction

 

Teratogenecity

Assessment Teratogenicity

Genetic Toxicity in-vitro

Genetic Toxicity in-Vivo

Assessment Mutagenicity

Epidemiology

Further Information

 

_________________________________________________________________________________

Acute Oral Tox

 

 

 

Component: Tetramethylammonium hydroxide

Acute Dermal tox

Acute dermal toxicity

 

2.1 %(m)

A single 4h semi-occlusive application to intact rabbit skin produced no signs of dermal irritation.

No clinical signs of toxicity were observed.

Testing complied with OECD 404 and EPA TSCA 40 CFR Part 798 standard protocols.

DOT Corrosivity testing conducted on stainless steel and laboratory animals determined that this product is not corrosive.

 

Component: Tetramethylammonium hydroxide

Acute Dermal tox

Acute dermal toxicity

 

3.5 %(m)

A single 4h semi-occlusive application to intact rabbit skin produced minimal signs of irritation ( mean scores for erythema or edema less than 2).

No clinical signs of toxicity were observed.

Testing complied with OECD 404 and EPA TSCA 40 CFR Part 798 standard protocols.

 

Component: Tetramethylammonium hydroxide

Acute Dermal tox

Acute dermal toxicity

 

5 %(m)

A single 4h semi-occlusive application to intactrabbit skin produced burns (full thickness destruction of skin).

This material is corrosive.

No clinical signs of toxicity were observed.

Testing complied with OECD 404 and EPA TSCA 40 CFR Part 798 standard protocols.

Corrosive to aluminum per DOT corrosivity testing.

 

Component: Tetramethylammonium hydroxide

Acute Dermal tox

Acute dermal toxicity

 

7 %(m)

A single 4h semi-occlusive application to intactrabbit skin produced burns (full thickness destruction of skin).

This material is corrosive.

No clinical signs of toxicity were observed.

Testing complied with OECD 404 and EPA TSCA 40 CFR Part 798 standard protocols.

Corrosive to aluminum per DOT corrosivity testing.

 

Component: Tetramethylammonium hydroxide

Acute Dermal tox

Acute dermal toxicity

 

<5% (w/v):

Repeated application to rat skin for 6 h/d, 5 d/wk for 4 weeks did not produce systemic toxicity.

Test material was applied continuously through a reservoir affixed to shaved animal backs.

 

Component: Tetramethylammonium hydroxide

Acute Dermal tox

Acute dermal toxicity

 

>=5% (w/v):

Repeated application to rat skin for 6h/d, 5d/wk for 4 weeks produced rapid toxicity and following effects:

convulsions

death

Effects were noted after 2 hours of initial application.

Test material was applied continuously through a reservoir affixed to shaved animal backs.

 

Component: Tetramethylammonium hydroxide

Acute Dermal tox

Acute dermal toxicity

 

LD50 guinea pig  25 mg/kg

100% (by weight).

 

 

Acute tox other route

 

Skin irritation

 

Eye irritation

 

Sensitization

 

_________________________________________________________________________________

 

Respiratory system irritation

Chronic/sub-chronic tox

Carcinogenicity

Assessment Carcinogenicity

Toxicity to reproduction

Assessment Toxicity to Reproduction

 

Teratogenecity

Assessment Teratogenicity

Genetic Toxicity in-vitro

Genetic Toxicity in-Vivo

Assessment Mutagenicity

Epidemiology

Further Information

_________________________________________________________________________________

 

Respiratory system irritation

Chronic/sub-chronic tox

Carcinogenicity

Assessment Carcinogenicity

Toxicity to reproduction

Assessment Toxicity to Reproduction

 

Teratogenecity

Assessment Teratogenicity

Genetic Toxicity in-vitro

Genetic Toxicity in-Vivo

Assessment Mutagenicity

Epidemiology

Further Information

_________________________________________________________________________________

 

Respiratory system irritation

Chronic/sub-chronic tox

Carcinogenicity

Assessment Carcinogenicity

Toxicity to reproduction

Assessment Toxicity to Reproduction

 

Teratogenecity

Assessment Teratogenicity

Genetic Toxicity in-vitro

Genetic Toxicity in-Vivo

Assessment Mutagenicity

Epidemiology

Further Information

 

12. ECOLOGICAL INFORMATION

Ecotoxicological information on this product or its components appear in this section when such data is available.

 

 

Section 12 Ecological Information

__________________________________________________________________________________________

 

Additional remarks

Ecotoxicity Effects

 

Chemical Fate Information

Additional remarks

 

Tetramethylammonium hydroxide

Ecotoxicity Effects

Ecotoxicity effects

Toxicity to fish

Toxicity to algae

Toxicity to bacteria

Toxicity to aquatic inverterbrates

Toxicity to aquatic invertebrates

 LC50 ceriodaphnia dubia (water flea) 96 h 

0.07 - 1.2 mg/l

A pH neutralized solution has been shown to be toxic to aquatic organisms.

 

 

Toxic to soil organisms

 

Chemical Fate Information

Additional remarks

Ecotoxicity Effects

 

Chemical Fate Information

Additional remarks

 

13. DISPOSAL CONSIDERATIONS

Environmental precautions

Environmental precautions: Prevent the material from entering drains or water courses.

Do not discharge directly to a water source.

Advise Authorities if spillage has entered watercourse or sewer or has contaminated soil or vegetation.

 

Section 13 Disposal Considerations

Waste Classification

Disposal

Dispose in accordance with all local, state (provincial), and federal regulations.  Under RCRA, it is the responsibility of the product's user to determine at the time of disposal, whether the product meets RCRA criteria for hazardous waste.  This is because the product uses, transformations, mixtures, processes, etc. may render the resulting materials hazardous. 

Do not remove label until container is thoroughly cleaned.  Empty containers may contain hazardous residues.  This material and its container must be disposed of in a safe way. 

Contaminated packaging

 EU waste code

 

 

14. TRANSPORT INFORMATION

Japanese FSL and PDSC statements

 

US DOT Information

DOT

 

 

Not regulated for transport 

 

 

IMDG (International Ocean)

IMO/IMDG

 

 

Not regulated (Not dangerous for transport) 

 

 

15. REGULATORY INFORMATION

Section 15 Regulatory Information

Workplace Classification

 

Canadian WHMIS Classification

 

EU Label Phrases

 

SARA 311/312

SARA Title III: Section 311/312 Categorizations (40CFR370): Immediate health hazard

 

SARA 313

SARA Title III: Section 313 Information (40CFR372)

This product does not contain a chemical which is listed in Section 313 at or above de minimis concentrations.

 

TSCA 12b

U.S. Toxic Substances Control Act (TSCA) Section 12(b) Export Notification (40 CFR 707, Subpt D):

U.S. Toxic Substances Control Act (TSCA) Section 12(b) Export Notification (40 CFR 707, Subpt D)

This product does not contain any substances subject to Section 12(b) export notification.

 

 

CERCLA

HAPS/ODS

Inventories EU

Inventories ex-EU

 

US. Toxic Substances Control Act (TSCA)  All components of this product are in compliance with the inventory listing requirements of the U.S. Toxic Substances Control Act (TSCA) Chemical Substance Inventory.

 

 

 

National 1

National 2

National 3

Not Japan

Regional (States)

California (Proposition 65)

This product does not contain materials which the State of California has found to cause cancer, birth defects or other reproductive harm.

 

 

16. OTHER INFORMATION

 

Hazard Rating

 

Health

Fire

Reactivity

 

NFPA

3

0

0

 

 

EU Label Phrases

 

Legend

Legend

ACGIH

American Conference of Governmental Industrial Hygienists

BAc

Butyl acetate

OSHA

Occupational Safety and Health Administration

PEL

Permissible Exposure Limit

STEL

Short Term Exposure Limit (STEL):

TLV

Threshold Limit Value

TWA

Time Weighted Average (TWA):

|

Bar denotes a revision from prior MSDS.

 

 

 

The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text.

Version: 2.0

 

Print Date:

09/04/2008

Layout 353536